The number of classification entries (TC) used is calculated, as follows:
(2 * 1)nc + (2 * 1)h1 + (2 * 1)ef + (2 * 1)h2 + (2 * 0)l1 + (2 * 2)af + (2 * 1)l2 + (2 * 1)be = 16
The number of meters (TP) used are: 2 ( Meters 1,9 – Note that meters 2 and 12 are not accounted
for, since its not associated with any FC).
7210 SAS-X and 7210 SAS-R6 OS Quality of Service Guide
exit
fc "l2" create
exit
fc "nc" create
exit
lsp-exp 1 fc l2
lsp-exp 2 fc af
lsp-exp 3 fc af
lsp-exp 4 fc h2
lsp-exp 5 fc ef
lsp-exp 6 fc h1
lsp-exp 7 fc nc
exit
egress
exit