Alcatel-Lucent 7210 SAS-R6 OS Quality Of Service Manual page 126

Service access switch
Table of Contents

Advertisement

Service Management Tasks
exit
The number of classification entries (TC) used is calculated, as follows:
(2 * 2)nc + (2 * 0)h1 + (2 * 1)ef + (2 * 0)h2 + (2 * 0)l1 + (2 * 1)af + (2 * 1)l2 + (0 * 0)be =
10
The numbers of meters (TP) used is: 6 (Meters 2, 3, 4, 7, 8, 12).
Page 126
7210 SAS-X and 7210 SAS-R6 OS Quality of Service Guide
exit
meter 8 multipoint create
exit
meter 9 multipoint create
exit
meter 12 multipoint create
exit
fc "af" create
meter 2
multicast-meter 12
exit
fc "ef" create
meter 4
multicast-meter 8
exit
fc "h2" create
exit
fc "l2" create
meter 3
multicast-meter 7
exit
fc "nc" create
meter 4
multicast-meter 8
exit
lsp-exp 1 fc l2
lsp-exp 3 fc af
lsp-exp 5 fc ef
lsp-exp 7 fc nc
exit
egress
exit