Alcatel-Lucent 7210 SAS-R6 OS Quality Of Service Manual page 124

Service access switch
Table of Contents

Advertisement

Service Management Tasks
Example 6
network 6 network-policy-type ip-interface create
description "network-policy-6"
exit
The number of classification entries (TC) used is calculated, as follows:
(2 * 1)nc + (2 * 1)h1 + (2 * 1)ef + (2 * 1)h2 + (2 * 0)l1 + (2 * 2)af + (2 * 1)l2 + (2 * 1)be = 16
The number of meters (TP) used are: 5 ( Meters 1,2,3,9,12).
Page 124
7210 SAS-X and 7210 SAS-R6 OS Quality of Service Guide
ingress
default-action fc be
meter 1 create
exit
meter 2 create
exit
meter 3 create
exit
meter 9 multipoint create
exit
meter 12 multipoint create
exit
fc "af" create
meter 2
multicast-meter 12
exit
fc "be" create
exit
fc "ef" create
exit
fc "h1" create
meter 3
exit
fc "h2" create
exit
fc "l2" create
exit
fc "nc" create
meter 3
exit
lsp-exp 1 fc l2
lsp-exp 2 fc af
lsp-exp 3 fc af
lsp-exp 4 fc h2
lsp-exp 5 fc ef
lsp-exp 6 fc h1
lsp-exp 7 fc nc
exit
egress
exit

Advertisement