(1)
C0900: 3rd Drawer Lift-Up Motor Failure
(2)
C0950: 4th Drawer Lift-Up Motor Failure
<Detection Timing>
Malfunction
Code
C0900
The Lift-Up Sensor is not blocked even after the set period of time has
elapsed after the paper lift-up operation for the drawer began.
C0950
Action
Lift-Up Motor 1 (M124-PF)
Lift-Up Motor 2 (M125-PF)
Lift-Up Sensor 1 (PC114-PF)
Lift-Up Sensor 2 (PC123-PF)
Step
Operations
Check the connectors of each
motor and sensor for proper con-
1
nection, and correct as neces-
sary.
Check the connector of each
2
motor for proper drive coupling,
and correct as necessary.
Check the PU1 connector for
3
proper connection, and correct
as necessary.
4
PC114-PF sensor check
5
PC123-PF sensor check
6
M124-PF operation check
7
M125-PF operation check
8
PWB-C2 PF replacement
9
PWB-A replacement
10
PU1 replacement
Description
Relevant Electrical Components
Control Board (PWB-C2 PF)
Copier Master Board (PWB-A)
Copier Power Supply Unit (PU1)
Ref.
Page
—
—
—
☞ T-1
PWB-C2 PF PJ6C2 PF-3
☞ T-1
PWB-C2 PF PJ10C2 PF-3
PWB-C2 PF PJ4C2 PF-
☞ T-3
☞ T-3
—
—
—
T-13
WIRING DIAGRAM
Control signal
—
—
—
5,4
PWB-C2 PF
PJ8C2 PF-12,13
—
—
—
Location
(Electrical
Components)
—
—
—
G-3
D-8
D-3
G-3
E-5
—
—