7 - 44
COOLING SYSTEM
SPECIFICATIONS (Continued)
COOLING SYSTEM
DESCRIPTION
Automatic Belt Tensioner to
Mounting
Bracket—Bolts(5.2L/5.9L)
Automatic Belt Tensioner to
Block—Bolts
(4.7L)
Automatic Belt Tensioner
Pulley—Bolt
Block Heater—Bolt
Generator/Compressor
Mounting
Bracket—Bolts
# 1 and 2
Fan Shroud Mounting—Bolts
Fan Blade to Fan Drive—
Bolts
Idler Pulley—Bolt
Radiator to Support—Bolts
Thermostat Housing—Bolts
Transmission Auxiliary Oil
Cooler—Bolts
Upper Radiator Closure
Panel—Bolts
Water Pump—Bolts
N·m
Ft.
Lbs.
67
50
41
30
61
45
2
54
40
# 3
40
30
6
23
17
54
40
23
23
10
10
40
30
SPECIAL TOOLS
In.
COOLING
Lbs.
17
Pliers Constant Pressure Hose Clamp—6094
50
Cooling System Pressure Tester—7700A
200
200
90
90
3/8" Disconnect Tool—6935
DN

Advertisement