WEG CFW-09 User Manual page 307

Frequency inverter
Hide thumbs Also See for CFW-09:
Table of Contents

Advertisement

CHAPTER 8 - CFW-09 OPTIONS AND ACCESSORIES
308
EL8:
0 = ramp enabling (run/stop) inactive
1 = ramp enabling
EL9:
0 = general enabling inactive
1 = general enabling active
EL10:
0 = reverse
1 = forward
EL11:
0 = JOG inactive
1 = JOG active
EL12:
0 = local
1 = remote
EL13:
0 = without undervoltage
1 = with undervoltage
EL14 :
not used
EL15:
0 = without error
1 = with error
Error Code: hexadecimal error number
E00  00H
Ex.:
E01  01H
E10  0AH
V03 (code 00803):
Selection of the Logical Control
Writing variable, whose bits have the following meaning:
BYTE HIGH: desired action mask. The corresponding bit should be set to 1, so
the action happens.
C L 1 5 C L 1 4 C L 1 3 C L 1 2 C L 11
MSB
- CL8: 1 = enabling ramp (Start/Stop)
- CL9: 1 = general enabling
- CL10: 1 = Forward/Reverse rotation
- CL11: 1 = JOG
- CL12: 1 = Local/Remote
- CL13: not used
- CL14: not used
- CL15: 1 = inverter "RESET"
BYTE LOW: logical level of the desired action.
C L 7
C L 6
C L 5
MSB
- CL0: 1 = enabling (Start)
0 = disabling by ramp (Stop)
- CL1: 1 = enabling
0 = general disabling (stops by inertia)
- CL2: 1 = forward
0 = reverse
- CL3: 1 = JOG active
0 = JOG inactive
- CL4: 1 = remote
0 = local
C L 1 0
C L 9
C L 4
C L 3
C L 2
C L 1
Inverter
enabled
EL8 = EL9 = 1
C L 8
LSB
C L 0
LSB

Hide quick links: