WEG CFW-09 User Manual page 27

Frequency inverter
Hide thumbs Also See for CFW-09:
Table of Contents

Advertisement

CFW-09 - QUICK PARAMETER REFERENCE
Parameters
Function
(1)
P313
Type of disabling by E28/E29/E30
(1)
P314
Time for Serial Watchdog
Action
P318
Watchdog detection for the
PLC board
Flying Start/Ride-Through
(1)
P320
Flying Start/Ride-Through
P321
(6)
Ud Line Loss Level
P322
(6)
Ud Ride-Through
P323
(6)
Ud Line Recover Level
28
Adjustable Range
6 = Modbus-RTU, 19200 bps,
even parity
7 = Modbus-RTU, 38400 bps,
no parity
8 = Modbus-RTU, 38400 bps,
odd parity
9 = Modbus-RTU, 38400 bps,
even parity
0 = Disable via Start/Stop
0 = Disable via Start/Stop
1 = Disable via General
Enable
2 = Not Used
3 = Changes to LOCAL 1
4 = Changes to LOCAL 2
5 = Causes Fatal Error
0.0 = Disable
0.0 = Disabled
0.1 to 999.0 = Enable
0 = Off
0 = Off
1 = On
0 = Inactive
0 = Inactive
1 = Flying Start
2 = Flying Start/Ride-Through
3 = Ride-Through
178 to 282 (P296 = 0)
252
307 to 487 (P296 = 1)
436
324 to 513 (P296 = 2)
459
356 to 564 (P296 = 3)
505
388 to 615 (P296 = 4)
550
425 to 674 (P296 = 5)
602
466 to 737 (P296 = 6)
660
486 to 770 (P296 = 7)
689
559 to 885 (P296 = 8)
792
178 to 282 (P296 = 0)
245
307 to 487 (P296 = 1)
423
324 to 513 (P296 = 2)
446
356 to 564 (P296 = 3)
490
388 to 615 (P296 = 4)
535
425 to 674 (P296 = 5)
588
466 to 737 (P296 = 6)
644
486 to 770 (P296 = 7)
672
559 to 885 (P296 = 8)
773
178 to 282 (P296 = 0)
267
307 to 487 (P296 = 1)
461
324 to 513 (P296 = 2)
486
356 to 564 (P296 = 3)
534
388 to 615 (P296 = 4)
583
425 to 674 (P296 = 5)
638
466 to 737 (P296 = 6)
699
486 to 770 (P296 = 7)
729
Factory
Unit
Setting
-
s
-
V
V
V
User's
Page
Setting
199
200
200
200
200
201
202