CHAPTER 6 - DETAILED PARAMETER DESCRIPTION
[Factory Setting]
Parameter
P206
Auto-Reset
Time
P207
Reference
Engineering Unit 1
P208
(2)(11)
Reference Scale
Factor
150
Range
Unit
Description / Notes
0 to 255
In the event of a fault trip, except for E09, E24, E31 and E41, the CFW-09
can initiate an automatic reset after the time given by P206 is elapsed.
[ 0 ]
1 s
If P206  2 Auto-Reset does not occur.
If after Auto-Reset the same fault is repeated three times consecutively,
the Auto-Reset function will be disabled. A fault is considered consecutive
if it happens again within 30 seconds after Auto-Reset.
Hence, if an error occurs four consecutive times, it will be permanently
indicated (and the inverter will be disabled).
32 to 127
This parameter is useful only for inverters provided with a keypad with
[ 114 = r ]
LCD display.
-
P207 is used to apply a customized display to P001 (Speed reference)
and P002 (motor speed). The letters rpm can be changed to user selected
characters, E.g. CFM, L/s, etc.
The Reference Engineering Unit is formed by three characters, which
will be applied to the Speed Reference (P001) and the Motor Speed
(P002) LCD display indications. P207 defines the left character. P216
defines the center character and P217 the right character.
All characters correspondent to the ASCII code from 32 to 127 can be
chosen.
Examples: A, B, ... , Y, Z, a, b, ... , y, z, 0, 1, ... , 9, #, $, %, (, ), *, +,...
1 to 18000
Defines how the Speed Reference (P001) and the Motor Speed (P002)
[ 1800 (1500) ]
will be displayed.
1
For indicating the values in rpm:
Set the synchronous speed according to table 6.19.
For indicating other values:
The displayed value when the motor is running at synchronous speed
can be calculated through the following equations:
P002 = Speed x P208 / Sync speed x (10)
Motor Pole
Frequency
Number
2
4
50 Hz
6
8
2
4
60 Hz
6
8
Table 6.19 - Synchronous speed reference in rpm
Syncronous
Speed - rpm
3000
1500
1000
750
3600
1800
1200
900
P210