s) Operation of Parameters P353 to P356 with Ix < Imr.
Current
Imag
Magnetized
Motor
Start/Stop
P356
RLx or DOx Output
(brake activation)
Speed Reference
Real Brake
Real Speed
Figure 6.39 (cont.) s) - Details about the operation of the digital and relay output functions
Ix
CHAPTER 6 - DETAILED PARAMETER DESCRIPTION
P354
P353
P355
Nx
Nx
Reset Pulse for the
integrator of the
speed regulator
Accepted only
after P355
P356
191