CHAPTER 6 - DETAILED PARAMETER DESCRIPTION
[Factory Setting]
Parameter
(1)
P363
Stabilization Time
Available only
if P361 = 1 (On)
(1)
P364
Slack Cable Time
Available only
if P361 = 1 (On)
P365
(1)
0.0 to 1.3 x P295
Slack Cable Level
Available only
if P361 = 1 (On)
(1)
P366
0.0 to 1.3 x P295
Light Load Level
Available only
if P361 = 1 (On)
(1)
P367
0.0 to 1.8 x P295
Overweight Level
Available only
if P361 = 1 (On)
P368
(1)
Speed Reference Gain
Available only
if P361 = 1 (On)
P369
(2) (11)
Frequency Fx
210
Range
Unit
Description / Notes
0.1 to 10.0
Time that the CFW-09 waits before starting the load detection after the
[ 0.1 ]
stabilization speed has been reached.
0.1 s
0.0 to 60.0
Time that the CFW-09 waits to commutate the digital (DOx) and relay
[0.0]
outputs set to the option "Slack Cable Detection". If the Slack Cable
0.1 s
condition is no longer valid, the CFW-09 resets the digital or relay outputs.
Output current value used to detect the slack cable condition.
[0.1 x P295]
0.1 A
Output current value used to detect the light load condition. At the end of
[0.3 x P295]
this process the speed reference is increased according to P368. The
0.1 A
new speed value is N = N* x P368. This condition is reset when the
motor remains stopped for 1 second.
Output current value used to detect the overweight condition. This function
[1.1 x P295]
is only enabled during the stabilization time. This condition is reset when
0.1 A
the motor remains stopped (N = 0) for 1 second.
1.000 to 2.000
This parameter increases the speed reference under the light load
condition.
[1.000]
-
0.0 to 300.0
It is used in functions of the digital and relay outputs: F > Fx.
[4.0]
0.1 Hz
NOTE!
When P364 = 0, the detection logic of slack cable is disabled.
NOTE!
This condition is verified only during the stabilization time.
NOTE!
This condition is verified only during the stabilization time.