WEG CFW-09 User Manual page 256

Frequency inverter
Hide thumbs Also See for CFW-09:
Table of Contents

Advertisement

CONFIGURATIONS
Expansion
Board
EBC1.01
EBC1.02
EBC1.03
NOTE!
The terminals XC10:22 and XC10:23 (refer to figure 8.9), should be used only
for encoder supply, when encoder power supply is not coming from DB9
connection.
MOUNTING OF THE ENCODER
For mounting the encoder on the motor, follow the recommendations below:
Couple the encoder directly to the motor shaft (use a flexible coupling
without torsional flexibility);
Both the shaft and the metallic frame of the encoder must be electrically
isolated from the motor. (min. spacing: 3 mm (0.119 in));
Use high quality flexible couplings to prevent mechanical oscillation or
backlash.
The electrical connection must be made with shielded cable, maintaining a
minimum distance of about 254 mm (10 in) from other wiring (power, control
cables, etc.). If possible, install the encoder cable in a metallic conduit.
At start-up, program Parameter P202 - type of control - = 4 (vector with
encoder) to operate the motor with speed feedback through incremental
encoder. For more details about Vector Control operation, refer to chapter 5.
Encoder Connector***
red
A
A
blue
H
A
yellow
B
B
green
I
B
C
Z
J
Z
white
D
+VE
brown
F
COM
E
NC
cable shield
G
Encoder
Max. Recommended lenght: 100 m (300 ft)
*
External Power Supply Voltage for encoder: 5 to 15 Vdc, consumption = 40 mA plus consumption of the
encoder.
** 0 V reference of the Power Supply Voltage.
*** Valid pin position with encoder HS35B models from Dynapar. For other encoder models, check the
correct connection to meet the required sequence.
CHAPTER 8 - CFW-09 OPTIONS AND ACCESSORIES
Power
Encoder
Supply
Voltage
External 5 V
5 V
External 8 to 15 V
8 to 15 V
Internal 5 V
5 V
Internal 12 V
12 V
Table 8.5 - EBC1 board configuration
Figure 8.11 – EBC1 encoder input
Customer
Action
Commutate switch S8 to ON, refer
to figure 8.9
None
None
None
Connector
Signal
Description
XC9
XC10
3
26
A
2
25
A
Encoder Signal
1
28
B
(5 to 15 V)
9
27
B
8
-
Z
7
-
Z
Power Supply*
4
21, 22
+VE
0 V Reference**
6
23, 24
COM
Ground
5
-
CFW-09 EBC1 Board
Connector XC9 (DB9 - Male)
257