WEG CFW-09 User Manual page 142

Frequency inverter
Hide thumbs Also See for CFW-09:
Table of Contents

Advertisement

[Factory Setting]
Parameter
P163
Local Speed
Reference Offset
P164
Remote Speed
Reference Offset
These para-
meters (P160 to P164)
are shown on the
display(s) only when
P202 = 3 or 4 (Vector
Control)
P165
0.012 to 1.000
Speed Filter
This para-
meter is shown on
the display(s) only
when P202 = 3 or 4
(Vector Control)
P166
Speed Regulator
Differential Gain
This para-
meter is shown on
the display(s) only
when P202 = 3 or 4
(Vector Control)
P167
(4)
Proportional Gain of
the Current Regulator
(4)
P168
Integral Gain of the
Current Regulator
Parameters
(P166 and P167 and
P168) are shown
on the display(s)
only when P202 = 3
or 4 (Vector
Control)
Range
Unit
Description / Notes
-999 to 999
Parameters P163 or P164 may be used to compensate a bias offset at
[ 0 ]
the analog input signals, when the speed reference is given by the analog
1
inputs (AI1 to AI4).
Refer to figure 6.26.
-999 to 999
[ 0 ]
1
Adjusts the time constant for the Speed Filter. Refer to figure 6.27 a).
[ 0.012 ]
0.001 s
The differential action may reduce the effects on the motor speed caused
0.00 to 7.99
by the load variation. Refer to figure 6.27 a).
[ 0.00 ]
-
0.00 to 1.99
The parameters P167 and P168 are set by the self-tuning routine as a
[ 0.5 ]
function of parameters P411 and P409, respectively.
0.01
0.000 to 1.999
[0.010 ]
0.001
CHAPTER 6 - DETAILED PARAMETER DESCRIPTION
NOTE!
In general, this parameter shall not be changed. Increasing the
speed filter value renders the system response slower.
P166
0.0
0.01 to 7.99
Table 6.10 - Speed regulator differential gain action
NOTE!
These parameters must not be changed.
Differential Gain Action
Off
On
143