Summary of Revisions
Revision
1
First Edition.
2
Inclusion of the functions Fieldbus and Serial Communication.
2
Inclusion of the Spare Part List.
2
Dimension Changing.
3
Inclusion of the PID Regulator.
4
Inclusion of the German Language - Ride-through and Flying Start functions.
4
Inclusion of DBW-01; KIT KME; DC Link Inductor.
5
Inclusion of Item 3.3 - CE Installation.
5
Inclusion of new functions such as Ride-Through for Vector Control, Motor Phase Loss.
5
New I/O Expansion Boards EBB.04 and EBB.05.
6
General Revision.
7
Inclusion of the models from 2.9 to 32 A / 500-600 V.
8
Inclusion of new functions:
Control Type of the Speed Regulator, Speed Regulator Differential Gain, Stop Mode Selection,
Access to the parameters with different content than default, Hysteresis for Nx/Ny, kWh
Counter, Load User 1 and 2 the factory Hours Hx, via DIx, Parameter Setting Disable via DIx,
Help Message for E24, "P406 = 2 in Vector Control", Automatic SensorLess Set of P525, Last
10 errors indication, Motor Torque indication via AOx.
8
New optional boards: EBC and PLC1.
8
New model CFW-09 SHARK NEMA 4X/IP56.
8
New models for voltages, currents and powers: Models 500-600 V.
8
Inclusion of the items 8.14 Modbus-RTU, 8.17 CFW-09 Supplied by the DC Link - Line HD,
8.18 CFW-09 RB Regenerative Converter.
8
Updating of the Spare Part List.
9
Inclusion of new functions:
Overcurrent Protection, Default factory reset 50 Hz, Timer Relay, Ramp Holding.
9
New lines of the current and power supply.
9
PID Regulator to "Academic" Changing.
10
General revision and update of the software version (2.6X to 3.1X):
Change on the maximum value of P156 and P401 for some models; Change on the maximum
value of P331; Change on the factory default value of P404.
11
New functions;
Incorporation of the Mechanical Brake Logic for cranes, Load Detection Logic and addition of
option "Indication of Torque Current Polarity" at the DOx and RLx outputs; VVW Control; DC
Braking for VVW and Sensorless; Flying Start function for the Sensorless Control; support for
EtherNet/IP communication board; read/write function for the PLC board parameters through
Modbus; Indication of the Analog Outputs values in read only parameters P027 to P030;
Simultaneous indication of the speed and current in parameter P070; P313 = 4 (Changes to
LOCAL mode keeping the commands);Regulation of the maximum torque current through
options AI1+AI2 and AI2+AI3; function F > Fx; function ready 2.
12
Updating of the software version to V4.0X.
Updating of the parameters P309 and P313.
Addition of new parameters: P335, P336, P337, P338, P340, P341, P342, P343, P344 and P346.
New options for fault Reset.
General revision.
The table below describes all revisions made to this manual.
Description
Section
-
Refer to item 8.12 and 8.13
Refer to item 7.5
Refer to item 3.1.2 and 9.4
Refer to item 6
Refer to item 6
Refer to item 8
Refer to item 3
Refer to item 6
Refer to item 8
-
Refer to items 2.4; 3.1;
3.2.1; 3.3; 4.2; 6.2; 6.3; 7.1;
7.2; 7.4; 7.5; 8.7.1; 8.10.1;
9.1 and 9.1.3
Refer to item 6
Refer to item 8
Refer to item 8
Refer to items 1 to 9
Refer to item 8
7
-
-
-
-
Refer to items I, 6, 7 and 8
-