• In order to prevent global warming, avoid releas-
ing HFC-134a into the atmosphere. Using a refrig-
erant recovery system, discharge and recycle the
gas.
(A)
(C)
(A) Goggles
(B) Gloves
(C) Avoid open flame
(D) No direct heat on container
(E) Do not discharge
(F) Loosen
General Description
(B)
(D)
(F)
(E)
AC-00007
HVAC SYSTEM (HEATER, VENTILATOR AND A/C)
5. O-RING CONNECTIONS
• Always use a new O-ring.
• In order to keep the O-rings free of lint which will
cause a refrigerant gas leak, perform work without
using gloves or waste cloths.
• Apply compressor oil to O-rings to avoid sticking,
before installation.
• Use a torque wrench to tighten the O-ring fittings.
Over-tightening will result in damage of the O-ring
and deformation of the pipe end.
• If the work is interrupted before completing pipe
connections, recap the pipes, components and fit-
tings with a plug or tape to prevent foreign matter
from entering.
(A) Seal
• Visually check the surfaces and mating surfaces
of O-rings, threads and connecting points. If a fail-
ure is found, replace the applicable parts.