Intel 80C186EA User Manual page 73

Hide thumbs Also See for 80C186EA:
Table of Contents

Advertisement

OVERVIEW OF THE 80C186 FAMILY ARCHITECTURE
Breakpoint Interrupt — Type 3
The Breakpoint Interrupt is a single-byte version of the INT instruction. It is commonly used by
software debuggers to set breakpoints in RAM. Because the instruction is only one byte long, it
can substitute for any instruction.
Interrupt on Overflow — Type 4
The Interrupt on Overflow trap occurs if the Overflow Flag (OF) bit is set in the Processor Status
Word and the INT0 instruction is executed. Interrupt on Overflow is a common method for han-
dling arithmetic overflows conditionally.
Array Bounds Check — Type 5
An Array Bounds trap occurs when the array index is outside the array bounds during execution
of the BOUND instruction (see Appendix A, "80C186 Instruction Set Additions and Exten-
sions").
Invalid Opcode — Type 6
Execution of an undefined opcode causes an Invalid Opcode trap.
Escape Opcode — Type 7
The Escape Opcode fault is used for floating point emulation. With 80C186 Modular Core family
members, this fault is enabled by setting the Escape Trap (ET) bit in the Relocation Register (see
Chapter 4, "Peripheral Control Block"). When a floating point instruction is executed with the
Escape Trap bit set, the Escape Opcode fault occurs, and the Escape Opcode service routine em-
ulates the floating point instruction. If the Escape Trap bit is cleared, the CPU sends the floating
point instruction to an external 80C187.
80C188 Modular Core Family members do not support the 80C187 interface and always generate
the Escape Opcode Fault. The 80C186EA will generate the Escape Opcode Fault regardless of
the state of the Escape Trap bit unless it is in Numerics Mode.
Numerics Coprocessor Fault — Type 16
The Numerics Coprocessor fault is caused by an external 80C187 numerics coprocessor. The
80C187 reports the exception by asserting the ERROR pin. The 80C186 Modular Core checks
the ERROR pin only when executing a numerics instruction. A Numerics Coprocessor Fault in-
dicates that the previous numerics instruction caused the exception. The 80C187 saves the ad-
dress of the floating point instruction that caused the exception. The return address pushed onto
the stack during the interrupt processing points to the numerics instruction that detected the ex-
ception. This way, the last numerics instruction can be restarted.
2-44

Advertisement

Table of Contents
loading

This manual is also suitable for:

80c188ea

Table of Contents