CHAPTER 12
ONCE MODE
ONCE (pronounced "ahnce") Mode provides the ability to three-state all output, bidirectional, or
weakly held high/low pins except OSCOUT. To allow device operation with a crystal network,
OSCOUT does not three-state.
ONCE Mode electrically isolates the device from the rest of the board logic. This isolation allows
a bed-of-nails tester to drive the device pins directly for more accurate and thorough testing. An
in-circuit emulation probe uses ONCE Mode to isolate a surface-mounted device from board log-
ic and essentially "take over" operation of the board (without removing the soldered device from
the board).
12.1 ENTERING/LEAVING ONCE MODE
Forcing UCS and LCS low while RESIN is asserted (low) enables ONCE Mode (see Figure
12-1). Maintaining UCS and LCS and RESIN low continues to keep ONCE Mode active. Return-
ing UCS and LCS high exits ONCE Mode.
However, it is possible to keep ONCE Mode always active by deasserting RESIN while keeping
UCS and LCS low. Removing RESIN "latches" ONCE Mode and allows UCS and LCS to be
driven to any level. UCS and LCS must remain low for at least one clock beyond the time RESIN
is driven high. Asserting RESIN exits ONCE Mode, assuming UCS and LCS do not also remain
low (see Figure 12-1).
12-1