SET END PRESSURE ALARM
> Graphic END
> Set Point numeric val u e, fl a shing.
> Symbol PSI (or M)
Pressing and rel e asing the S button momentaril y (< 2
seconds) wil l increase the Set Point from 300 to 1500 PSI
(20 to 105 BAR) in 100 PSI (5 BAR) increments.
Depressing the S button wil l scrol l through the Set Points at
a rate of 4 Set Points per second until it is rel e ased.
Pressing and rel e asing the A button momentaril y (< 2
seconds) wil l save the setting and/or advance to the SET
PO2 ALARM screen with the Set Point fl a shing.
Pressing and rel e asing the A button repeatedl y (< 2
seconds each) wil l step through the other SET A screens.
Depressing the A and S buttons simul t aneousl y for 2
seconds wil l save the setting and revert to the SET A screen.
Depressing the M button for 2 seconds or if no button is
pressed for a period of 2 minutes operation wil l revert to
the NORM or GAUG SURF MAIN screen.
information incl u des (Fig. 33):
The END PRESSURE
Al a rm wil l activate
when Pressure in the
Tank (TMT 1, 2 , or
3) being used at the
time decreases to the
Al a rm Set Point.