NOTE: Upon entry into the following 3 Delayed
Violation Modes, the red LED flash and the Au-
dible Alarm will sound, even if Set OFF. When
these events occur, the Alarm cannot be ac-
knowledged (silenced) by pressing the A button.
NORM DELAYED VIOLATION #1
If you remain above the Required Ceil i ng Stop Depth for more
than 5 minutes, the ful l NIBG and DO N Arrow wil l fl a sh until
you descend bel o w the Required Stop Depth. The graphic
message DO N > TO > xxF (or xxM) wil l continue to scrol l .
> This is a continuation of a Conditional Viol a tion.
NORM DELAYED VIOLATION #
The El i te T3 cannot cal c ul a te Decompression times for Stop
Depths much greater than 60 FT (18 M) and offers no indication
of how much time spent underwater woul d resul t in the need for
a greater Stop Depth.
If the Decompression obl i gation requires a Ceil i ng Stop Depth
between 60 FT (18 M) and 70 FT (21 M), the NIBG wil l fl a sh
and the graphic message DECO > STOP > 60F (18M) wil l scrol l
at the top of the displ a y.
(Fig. 80)