Reactivating a Hot Swappable FRU
To connect an I/O card, as root, enter:
# cfgadm -c connect ap_id
where ap_id is the attachment-point ID.
To activate an I/O card, as root, enter:
# cfgadm -c configure ap_id
where ap_id is the attachment point ID.
5.2.3.3
Enabling Full Hot Swap on I/O Slots
If you changed the hot swap states for one or more I/O slots from the default full
hot swap setting to the basic hot swap setting, you can change use the cfgadm
utility to change the I/O slots back to the default full hot swap setting.
To enable full hot swap for an I/O slot in a Netra CT server, as root, enter:
# cfgadm -x enable_autoconfig ap_id
where ap_id is the attachment point ID in the server that you want to have full hot
swap enabled on. For example, to enable full hot swap for I/O slot 4, as root, you
could enter the following:
# cfgadm -x enable_autoconfig IO-4
You can also enable full hot swap on all slots at once by rebooting the server, which
automatically reverts back to the default full hot swap setting for all I/O slots.
5-8
Netra CT Server Service Manual • January 2004
Need help?
Do you have a question about the Netra CT and is the answer not in the manual?
Questions and answers