Sun Microsystems Netra CT Service Manual page 261

For the netra ct 810 server and netra ct 410 server
Hide thumbs Also See for Netra CT:
Table of Contents

Advertisement

Cause
2
An I
C error has resulted in an LED change failure. The LEDs on the system status
panel may give incorrect information as a result.
Action
Use the prtdiag tool to print the correct LED states. Remove and reinstall the
system controller board to correct the problem. Refer to
Section 8.2, "System
Controller Board" on page 8-6
for those instructions.
scsb#0: hsc_board_healthy: No Slot Info.
Cause
A disabled slot that is no longer being monitored by the system (due to errors or
user request) is having HEALTHY state changes and sending full hot swap style
interrupts to the CPU.
Action
Remove the I/O card from that slot. If the error messages repeat, set the I/O slot to
basic hot swap using the instructions in
Section 5.2.3.2, "Enabling Basic Hot Swap on
I/O Slots" on page
5-7.
scsb#0: hsc_enum_intr:
No Last Board Insertion Info.
Appendix C Error Messages
C-5