The output is similar to the following (note that the following output is for a Netra
CT 810 server; the output is similar for the Netra CT 410 server):
cphsc, instance #0
If you see value 'basic' underneath the default-hotswap-mode line, then
I
all of the slots in the Netra CT server have been set to basic hot swap. You should
see value 'disabled' for every slot in the system in this situation. Go to
Step 5 on page 6-11
If you see value 'full' underneath the default-hotswap-mode line, then at
I
least one of the slots in the Netra CT server has been set to full hot swap. You must
look at the entries for individual slots to determine if they have been set to basic
or full hot swap mode in this situation:
I
I
6-10
Netra CT Server Service Manual • January 2004
System properties:
name='instance' type=int items=1
name='default-hotswap-mode' type=string items=1
Driver properties:
name='AL-8-autoconfig' type=string items=1 dev=none
name='IO-7-autoconfig' type=string items=1 dev=none
name='IO-6-autoconfig' type=string items=1 dev=none
name='IO-5-autoconfig' type=string items=1 dev=none
name='IO-4-autoconfig' type=string items=1 dev=none
name='IO-3-autoconfig' type=string items=1 dev=none
name='IO-2-autoconfig' type=string items=1 dev=none
name='CPU-autoconfig' type=string items=1 dev=none
name='hotswap-mode' type=string items=1 dev=none
to manually disconnect the card before removing it.
If you see value 'enabled' underneath a <slot#-autoconfig> line, then
that slot is set to full hot swap. Go to
If you see value 'disabled' underneath a <slot#-autoconfig> line,
then that slot is set to basic hot swap. Go to
disconnect the card before removing it.
value=00000000
value='full'
value='enabled'
value='enabled'
value='enabled'
value='enabled'
value='enabled'
value='enabled'
value='enabled'
value='enabled'
value='full'
Step 7 on page 6-12
to remove the card.
Step 5 on page 6-11
to manually