Administration
RMON
Cisco Small Business 200E Series Advanced Smart Switch Command Reference
Parameter
variable
interval
rthreshold
fthreshold
revent
fevent
type
direction
name
Defaults
type—If unspecified, the type is absolute.
direction—If unspecified, the startup direction is rising-falling.
Description
A fully qualified SNMP object identifier that resolves to a
particular instance of an MIB object.
The interval in seconds over which the data is sampled
and compared with the rising and falling thresholds. The
range is 1–4294967295.
The rising threshold. The range is 0–4294967295.
The falling threshold. The range is 0–4294967295.
The index of the event that is used when a rising threshold
is crossed. The range is 1–65535.
The event index used when a falling threshold is crossed.
The range is 1–300.
The method for sampling the variable and for calculating
the value to be compared against the thresholds. If the
method is absolute, the value of the selected variable is
compared directly with the thresholds at the end of the
sampling interval. If the method is delta, the selected
variable value at the last sample is subtracted from the
current value, and the difference compared with the
thresholds.
The alarm that might be sent when this entry is first set to
valid. If the first sample (after this entry becomes valid) is
greater than or equal to the rising threshold, and direction
is equal to rising or rising-falling, then a single rising alarm
is generated. If the first sample (after this entry becomes
valid) is less than or equal to the falling threshold, and
direction is equal to falling or rising-falling, then a single
falling alarm is generated.
Enter a name that identifies who configured this alarm. If
unspecified, the name is an empty string.