Figure 151
Figure 152
MAP 0500: fan and CTP card failure analysis
256
SAN32M1 Fabric Switch Installation and Service Manual
l. Select Exit from the File pull-down menu to close the
HyperTerminal application. The following message box appears:
Disconnect verification message
m. Click Yes. The following message box appears:
Save session device verification message
n. Click No to exit and close the HyperTerminal application.
o. Power off the maintenance terminal.
p. Disconnect the RS-232 modem cable from the switch and the
maintenance terminal. Replace the protective cap over the
maintenance port.
Was event code 433 reported?
NO
YES
↓
An unrecoverable Ethernet fault (CTP card failure) occurred.
Because the CTP card is not a FRU, replace the switch.
Contact the next level of support.
This MAP describes fault isolation for the CTP card (which is not a
FRU) and fans. Failure indicators include:
•
The amber LED on a fan illuminates.