NO
YES
↓
The switch appears operational. Exit MAP.
Contact the next level of support. Exit MAP.
24
One of the following mode-mismatch conditions was detected and an
ISL connection is not allowed:
•
The switch is configured for operation in Open Fabric 1.0 mode
and is connected to a fabric element not configured to Open
Fabric 1.0 mode.
•
The switch is configured for operation in Open Fabric 1.0 mode
and is connected to a legacy switch at the incorrect Exchange
Link Parameter (ELP) revision level.
•
The switch is configured for operation in Open Fabric 1.0 mode
and is connected to a non-IBM switch at the incorrect ELP
revision level.
•
The switch is configured for operation in McDATA Fabric 1.0
mode and is connected to a non-IBM switch.
Configure the switch interop mode:
a. Select Fabric Parameters from the Operating Parameters sub
menu. The Configure Fabric Parameters dialog box displays.
Configure fabric parameters dialog box
Figure 154
b. Select McDATA Fabric 1.0 or Open Fabric 1.0 from the Interop
Mode list box.
Chapter 3: Diagnostics
271