Map 0100: Power Distribution Analysis - IBM TotalStorage SAN32M1 Installation And Service Manual

Totalstorage
Hide thumbs Also See for TotalStorage SAN32M1:
Table of Contents

Advertisement

MAP 0100: power distribution analysis

218
SAN32M1 Fabric Switch Installation and Service Manual
53
The link incident record provides the attached switch port number(s)
and one or more of the following event codes and messages. Record
all event codes that may relate to the reported problem.
581 - Link interface incident - implicit incident.
582 - Link interface incident - bit-error threshold exceeded.
583 - Link failure - loss of signal or loss of synchronization.
584 - Link failure - not-operational primitive sequence (NOS)
received.
585 - Link failure - primitive sequence timeout.
586 - Link failure - invalid primitive sequence received for the
current link state.
Were one or more event codes found?
YES
NO
Perform switch fault isolation at the EFC Server.
Go to
step
3.
Go to
Table 10
on page 192.
This MAP describes fault isolation for the switch power distribution
system, including defective AC power cords or power supplies.
1
Was an event code 200, 201, 202, or 208 observed at the Event Log
(EFC Server) or at the SANpilot event log?
YES
NO
Go to
step
3.
2
The following table lists event codes, brief explanations of the codes,
and the associated steps that describe fault isolation procedures.

Advertisement

Table of Contents
loading

Table of Contents