Event Log
Event Code: 150
Message:
Zone Merge Failure
Severity:
Informational
Explanation:
There was a failure in the Zone Merge process during ISL initialization. Either a noncompatible Zone Set was
detected or there was a problem with delivery of the Zone Merge frame. This event is always preceded by an ISL
segmentation event (event code 70). This code's purpose is to explain the cause of the failure and segmentation.
It represents the reply from the neighboring switch in response to a Zone Merge frame that was sent to it.
Action:
The action depends on the reason for failure.
Event Data:
See following table: Event Data for Event Code 150.