MPC module events (600 through 699)

Event Code: 602
Message:
SBAR module anomaly detected
Severity:
Informational
Explanation:
Indicates that the control processor has detected a deviation in the normal operating mode or operating status of
the indicated SBAR module.
Action:
No action required. There will be an additional event generated (604) if this event results in an SBAR logic failure.
Event Data:
Byte 0 = Slot position
Byte 1 = Anomaly reason code (See following chart)
Bytes 4-7 = Elapsed millisecond tick count
Bytes 8-9 = High Availability error callout #1
Bytes 10-11 = High Availability error callout #2
Byte 12 = Detecting port
Byte 13 = Connected port
Byte 14 = Participating SBAR
Bytes 16-17 =.High Availability error callout #3
Bytes 18-19 =.High Availability error callout #4
Distribution:
Switch
Nonvolatile
System
Event Log
Event #602 Anomaly Reason Codes
Reason Code
Description
0x00
Utility bus error to SBAR
0x01
Utility bus error to Port Module
0x02
Reserved
0x03
SBAR module detected utility bus parity error
0x04
Port module detected utility bus parity error
System
Event Log
Error
Indicator
EFC Server
E-Mail
Call-Home
Additional Data
HA Error Callouts (Words 2 & 4)
HA Error Callouts (Words 2 & 4)
HA Error Callouts (Words 2 & 4)
HA Error Callouts (Words 2 & 4)
HA Error Callouts (Words 2 & 4)
Appendix B: Event code tables
Host
Sense Info
Link Incident
489

Advertisement

Table of Contents
loading

Table of Contents