MAP 0500: Port failure or link incident analysis

122
SAN32M-2 Installation and Service Manual
5
As indicated by event code 433 or 440, the CTP card failed. Replace
the switch. Exit MAP.
6
As indicated by event code 810, 811, 812, or 850, an intermittent
thermal problem may result in switch failure. Reset the product. Refer
to
IML or reset switch
for instructions.
Was the maintenance action successful?
NO
YES
The product is operational. Exit MAP.
A CTP card failure is indicated. Replace the switch. Exit MAP.
This MAP describes fault isolation for small form factor pluggable
(SFP) optical transceivers and Fibre Channel link incidents. One or
more of the following indicate a failure:
Event code 080, 081, 083, 506, 507, 512, 514, 515, or 516 observed at
the Event Log (EFCM Basic Edition or Element Manager interface).
Event code 581, 582, 583, 584, 585, or 586 observed at the console
of an OSI server attached to the product reporting the problem.
An error message observed at the Link Incident Log (EFCM Basic
Edition or Element Manager interface).
1
Table 13
lists event codes, explanations, and MAP steps.
Table 13

MAP 500 event codes

Event
Explanation
code
080
Unauthorized worldwide name.
081
Invalid attachment.
083
Port set to inactive state.
Action
Go to
step
2.
Go to
step
3.
Go to
step
13.

Advertisement

Table of Contents
loading