Figure 193

Clean fiber-optic components

Data collection dialog box

7. Click Close to close the dialog box.
8. Remove the CD with the newly-collected maintenance data from
the EFC Server's CD-RW drive. Return the CD with the failed
FRU to IBM for failure analysis.
9. To ensure the backup application operates normally, replace the
original backup CD in the EFC Server's CD-RW drive.
Perform this procedure as directed in this publication and when
connecting or disconnecting fiber-optic cables from switch SFP
optical transceivers (if necessary). To clean fiber-optic components:
1. Obtain the appropriate tools (portable can of oil-free compressed
air and alcohol pads) from the fiber-optic cleaning kit.
2. Disconnect the fiber-optic cable from the SFP. Use compressed air
to blow any contaminants from the connector as shown in part 1
of
Figure
194.
— Keep the air nozzle approximately 50 millimeters (two inches)
from the end of the connector and hold the can upright.
— Blow compressed air on the surfaces and end of the connector
continuously for approximately five seconds