Clear Link Incident Alert(S) Dialog Box - IBM TotalStorage SAN32M1 Installation And Service Manual

Totalstorage
Hide thumbs Also See for TotalStorage SAN32M1:
Table of Contents

Advertisement

Figure 160
278
SAN32M1 Fabric Switch Installation and Service Manual
Contact IBM support personnel to obtain software maintenance
release 4.02.00. This release is required to correct the problem and
allow IBM switches to communicate with CNT UltraEdge WAN
Gateways. Exit MAP.
33
The switch and attached device are performing a Fibre Channel link
reset. This is a transient state. Wait approximately 30 seconds and
inspect port state and LED behavior.
Did the link recover and resume operation?
NO
YES
The Fibre Channel link and switch appear operational.
Exit MAP.
Go to
step
1.
34
A link incident message appeared in the Link Incident Log or in the
Link Incident field of the Port Properties dialog box; or an event code
581, 582, 583, 584, 585, or 586 was observed at the console of an
OSI server attached to the switch reporting the problem.
Clear the link incident for the port.
a. At the Hardware View, right-click the port. A pop-up menu
appears.
b. Select Clear Link Incident Alert(s). The Clear Link Incident
Alert(s) dialog box displays.

Clear link incident alert(s) dialog box

c. Select the This port (n) only radio button (where n is the port
number) and click OK. The link incident clears.
d. Monitor port operation for approximately five minutes.

Advertisement

Table of Contents
loading