Event Code: 806
Message:
Critically hot temperature warning (SBAR module thermal sensor).
Severity:
Major
Explanation:
The thermal sensor associated with the SBAR module has detected that the "hot" temperature threshold level
has been surpassed.
Action:
Perform the data collection procedure for this switch using the EFC Manager, save the data file to the EFC Zip
drive, and return the CD to IBM for analysis. Perform a system power-on reset. If the problem persists, replace
the switch.
Event Data:
No supplementary data included with this event.
Distribution:
Switch
Nonvolatile
System
Event Log
Event Code: 807
Message:
SBAR module shutdown due to thermal violation
Severity:
Major
Explanation:
The SBAR Module has been marked failed and power has been removed from the module due to excessive heat.
This event follows an indication that the SBAR module "hot" threshold level has been surpassed (event 806).
Action:
Perform the data collection procedure for this switch using the EFC Manager, save the data file to the EFC Zip
drive, and return the CD to IBM for analysis. Perform a system power-on reset. If the problem persists, replace
the switch.
Event Data:
No supplementary data included with this event.
Distribution:
Switch
Nonvolatile
System
Event Log
System
Event Log
Error
Indicator
System
Event Log
Error
Indicator
EFC Server
E-Mail
Call-Home
EFC Server
E-Mail
Call-Home
Appendix B: Event code tables
Host
Sense Info
Link Incident
Host
Sense Info
Link Incident
497

Advertisement

Table of Contents
loading

Table of Contents