MAP 0600: port failure and link incident analysis
This MAP describes fault isolation for small form factor pluggable
(SFP) transceivers and Fibre Channel link incidents. Failure indicators
include:
•
One or more amber LEDs on the Fibre Channel ports illuminate.
•
The amber emulated LED adjacent to a port graphic at the
Hardware View illuminates.
•
A blinking red and yellow diamond (failed FRU indicator) or
yellow triangle (attention indicator) appears at the alert panel of
the Product View or Hardware View.
•
An event code recorded at theEvent Log or the SANpilot event log.
•
A port operational state message or a Failed message at the Port
Properties dialog box or SANpilot interface.
•
A link incident event code recorded at the console of an OSI
server attached to the switch reporting the problem.
•
A link incident message at the Link Incident Log or Port Properties.
1
Was an event code 080, 081, 506, 507, 508, 512, or 514, observed at
the Event Log (EFC Server) or at the SANpilot event log?
NO
YES
↓
Go to
step
3.
2
Was an event code 581, 582, 583, 584, 585, or 586 observed at the
console of an OSI or FICON server attached to the switch reporting
the problem.?
YES
NO
↓
Go to
step
4.
3
The following table lists event codes, brief explanations of the codes,
and associated steps that describe fault isolation procedures.
Chapter 3: Diagnostics
261