Cmm Module Events (800 Through 899) - IBM TotalStorage SAN32M1 Installation And Service Manual

Totalstorage
Hide thumbs Also See for TotalStorage SAN32M1:
Table of Contents

Advertisement

CMM module events (800 through 899)

Event Code: 800
Message:
High-temperature warning (Port module thermal sensor).
Severity:
Major
Explanation:
The thermal sensor associated with the port module has detected that the "warm" temperature threshold level
has been surpassed.
Action:
Perform the data collection procedure for the switch using the EFC Manager, and return the CD to IBM for
analysis. Perform a system power-on reset. If the problem persists, replace the switch.
Event Data:
No supplementary data included with this event.
Distribution:
Switch
Nonvolatile
System
Event Log
Event Code: 801
Message:
Critically hot temperature warning (Port module thermal sensor)
Severity:
Major
Explanation:
The thermal sensor associated with the port module has detected that the "hot" temperature threshold level has
been surpassed.
Action:
Perform the data collection procedure for this switch using the EFC Manager, and return the CD to IBM for
analysis. Perform a system power-on reset. If the problem persists, replace the switch.
Event Data:
No supplementary data included with this event.
Distribution:
Switch
Nonvolatile
System
Event Log
System
Event Log
Error
Indicator
System
Event Log
Error
Indicator
EFC Server
E-Mail
Call-Home
EFC Server
E-Mail
Call-Home
Appendix B: Event code tables
Host
Sense Info
Link Incident
Host
Sense Info
Link Incident
495