Replacing A 2.5-Inch Hdd / Ssd Module; Required Tools; Preliminary Steps - Fujitsu PRIMERGY TX140 S1 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY TX140 S1:
Table of Contents

Advertisement

7.2.4

Replacing a 2.5-inch HDD / SSD module

Customer Replaceable Units (CRU)
Average task duration: 5 minutes
V
CAUTION!
Only remove an HDD / SSD module during operation if the drive is
not currently being accessed. Observe the indicators for the
corresponding HDD / SSD modules, see "PRIMERGY TX140 S1
Server - Operating manual".
Under no circumstances should you remove an HDD / SSD module
while the system is in operation if you are not sure that the drive is
operated by a RAID controller and belongs to a disk array that is
operating in RAID level 0, 1, 1E, 10, 5, 50, 6 or 60.
An HDD / SSD module can only be replaced during operation in
conjunction with a corresponding RAID configuration.
All HDD / SSD modules (drives) must be uniquely identified so that
they can be reinstalled in their original mounting locations later. If this
is not done, existing data can be lost.
7.2.4.1

Required tools

Preliminary and concluding steps: tool-less
Replacing a 2.5-inch HDD / SSD module: tool-less
7.2.4.2

Preliminary steps

Before replacing a 2.5-inch HDD / SSD module, perform the following steps:
Ê If applicable, open the rack door as described in section
door" on page
Ê Locate the defective server as described in section
server" on page
Ê When working on a tower server, open the HDD bay cover as described in
section
"Removing the HDD bay cover" on page
TX140 S1
61.
54.
Upgrade and Maintenance Manual
Hard disk drives / solid state drives
"Locating the defective
76.
"Opening the rack
171

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents