Locating The Defective Component; Local Diagnostic Indicators On The Front - Fujitsu PRIMERGY TX140 S1 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY TX140 S1:
Table of Contents

Advertisement

Indicator
CSS indicator
4.1.3

Locating the defective component

After determining the error class by the CSS or Global Error indicators (see
section
4.1.2 on page
system board allow you to identify the defective component.
I
For further information, refer to the "ServerView Suite Local Service
Concept (LSC)" manual available from the ServerView Suite DVD 2
supplied with your PRIMERGY server or online at
http://manuals.ts.fujitsu.com
http://jp.fujitsu.com/platform/server/primergy/manual/
4.1.3.1

Local diagnostic indicators on the front

Figure 6: Local diagnostic indicators on front panel
Ê Check the CSS indicator on the front and connector panels of the server:
Indicator
HDD error
1
indicator
TX140 S1
Status
Description
off
no critical event (CSS component)
yellow on
prefailure detected (CSS component)
yellow
CSS component failure
flashing
55) local diagnostic indicators on the front panel and
(EMEA market) or
Status
orange on
Upgrade and Maintenance Manual
Basic hardware procedures
Description
HDD / SSD, SAS / SATA backplane or
RAID controller failure detected
(Japanese market).
57

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents