Standard Power Supply; Replacing The Standard Power Supply Unit; Required Tools; Preliminary Steps - Fujitsu PRIMERGY TX140 S1 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY TX140 S1:
Table of Contents

Advertisement

Power supply
6.1

Standard power supply

6.1.1

Replacing the standard power supply unit

Field Replaceable Units (FRU)
Average task duration: 10 minutes
I
Note for servers using CMA (Cable Management Arm)
Since the installed CMA is blocking PSU modules, additional steps are
required in order to remove or replace PSU modules:
Ê Unlock the CMA stopper.
Ê Remove the CMA stopper with the mounted crossbar.
Ê Support the CMA stopper, the crossbar and the CMA arm including
cables with your right hand.
Ê Remove the PSU module and carefully install a new PSU module.
Ê Remount the complete assembly (CMA stopper, crossbar and CMA
arm) into the rail.
6.1.1.1

Required tools

Preliminary and concluding steps: tool-less
Replacing the power supply unit:
– Phillips PH2 / (+) No. 2 screw driver
6.1.1.2

Preliminary steps

Before replacing the standard power supply unit (PSU), perform the following
steps:
I
You are advised to perform this routine with the server in a horizontal
position.
Ê Disable BitLocker functionality as described in section
functionality" on page
124
93.
Upgrade and Maintenance Manual
"Disabling BitLocker
TX140 S1