System board and components

14.4.2 Preliminary steps

I
For BIOS version 1.15 or below, automatic restore functionality of the
customer BIOS settings is not available. In this case, proceed as follows:
Ê Please note down the current configuration or ask the customer to
provide individual settings. Restore settings to the new system board
manually.
Ê If the BIOS version is unclear due to a defective system board, please
ask the customer to provide individual BIOS settings.
For all other BIOS versions, the customer BIOS settings are restored
automatically. For the Japanese market, please refer to the "Parameter
configuration sheet".
Before replacing the system board, perform the following steps:
Ê Disable BitLocker functionality as described in section
functionality" on page
Ê Disable boot watchdog functionality as described in section
SVOM boot watchdog functionality" on page
Ê If applicable, open the rack door as described in section
door" on page
Ê Locate the desired server as described in section
server" on page
Ê Shut down the server as described in section
page
61.
Ê Remove the AC power cord from the cable tie and disconnect it from the
system as described in section
Ê Disconnect all external cables.
Ê When working on a rack-mounted server, extend it out of the rack as
described in section
If further required, remove the server from the rack as described in section
"Removing the server from the rack" on page
Ê Bring the server to its horizontal position.
454
93.
61.
54.
"Disconnecting power cords" on page
"Extending the server out of the rack" on page
Upgrade and Maintenance Manual
"Disabling BitLocker
"Disabling
94.
"Opening the rack
"Locating the defective
"Shutting down the server" on
66.
63.
65.
TX140 S1