Fujitsu PRIMERGY TX140 S1 Upgrade And Maintenance Manual page 60

Hide thumbs Also See for PRIMERGY TX140 S1:
Table of Contents

Advertisement

Basic hardware procedures
Component LEDs
I
LEDs A, B and C are visible from the outside on the server rear. All other
LEDs are only visible if the server cover has been opened. In order to
access memory LEDs (D), the system fan module needs to be removed
(see section
Indicator
GEL
A
(Global Error
LED)
CSS
B
(Customer Self
Service)
C
Identification
D
Memory
E
System fans
F
PCI card
G
AUX power
H
iRMC
60
"Removing the fan module" on page
Status
off
orange on
orange
flashing
off
yellow on
yellow
flashing
blue on
off
orange on
off
orange on
off
orange on
yellow on
green
flashing
Upgrade and Maintenance Manual
Description
no critical event (non CSS component)
prefailure detected (non CSS
component)
non CSS component failure
Possible reasons:
– sensors report overheating
– sensor is defective
– CPU error
– software reports an error
no critical event (CSS component)
prefailure detected (CSS component)
CSS component failure
server has been highlighted using
ServerView Operations Manager or the
ID button on the front panel for easy
identification
memory module operational
memory module failure
fan running
fan failure
PCI card operational
PCI card failure
AUX voltages are within range
iRMC S3 management controller is
operational
208).
TX140 S1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents