Configuring Bpdu Skewing On The Switch - Cisco WS-C6506 Software Manual

Catalyst 6500 series switch
Hide thumbs Also See for WS-C6506:
Table of Contents

Advertisement

Chapter 7
Configuring Spanning Tree
Console> (enable) show spantree mst config
Current (NVRAM) MST Region Configuration:
Configuration Name:arthur
Instance VLANs
-------- --------------------------------------------------------------
=======================================================================
NEW MST Region Configuration (Not committed yet)
Configuration Name:arthur
Instance VLANs
-------- --------------------------------------------------------------
1400
=======================================================================
Edit buffer is locked by:Console (pid 143)
Console> (enable) clear spantree mst 1400 vlan 900-998
Edit Buffer modified.
Use 'set spantree mst config commit' to apply the changes
Console> (enable) set spantree mst config commit
Console> (enable) show spantree mst config
Current (NVRAM) MST Region Configuration:
Configuration Name:arthur
Instance VLANs
-------- --------------------------------------------------------------
1400
=======================================================================
Console> (enable)

Configuring BPDU Skewing on the Switch

Commands that support the spanning-tree BPDU skewing allow you to perform these functions:
To change how spanning tree performs BPDU skewing statistics gathering, enter the set spantree
bpdu-skewing command. The bpdu-skewing command is disabled by default.
To configure the BPDU skewing statistics gathering for a VLAN, perform this task in privileged mode:
OL-8978-04
0
1,31-4094
2
2-20
3
21-30
0
1,31-899,1000-4094
2
2-20
3
21-30
900-999
0
1,31-998,1000-4094
2
2-20
3
21-30
999
Enable or disable BPDU skewing. The default is disabled.
Modify the show spantree summary output to show if the skew detection is enabled and for which
VLANs or PVST+ or MISTP instances the skew was detected.
Provide a display of the VLAN, PVST+, or MISTP instance and the port that is affected by the skew,
including this information:
The last skew duration (in absolute time)
The worst skew duration (in absolute time)
The date and time of the worst duration
Catalyst 6500 Series Switch Software Configuration Guide—Release 8.7
Configuring BPDU Skewing on the Switch
3 instances
Revision:23703
4 instances
Revision:23703
4 instances
Revision:23703
7-59

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 6506Catalyst 6509Catalyst 6513

Table of Contents