10. Depress the two safety locks (one on each side).
11. Slide the server chassis all the way into the rack.
12. Use the rack screws (#10-32 x 3/4) to secure the chassis and rack handles into the
rack.

Tool-less Full Extracting Slide Rail Rack Mount Servicing

1. To service the system, pull the system out from the rack.
2. Disconnect the power cable(s) and proceed with servicing the system.
3. When the servicing is completed, re-connect the power cable(s).
4. Pull up on the green tabs on each rail and slide the system back into the rack.
Note: Beware of cables when re-installing the system into the rack so that the cables do not get
pulled or interfered with.

Removing and Installing the Front Bezel

The front bezels are available as optional accessories for the Intel
SR2600UR/SR2625UR. The following front bezel options are available:
Bezel for use with the standard control panel (Product Order Code:
ADRBEZBLACK)
Bezel for use with the Intel
ADRLCDBEZEL)
To identify your front bezel, see the following figures. Note the orientation in the figures -
the control panel is at the right. If you are installing a bezel on your server system, make
sure you position it as shown.
®
Intel
Server System SR2600UR/SR2625UR Service Guide
®
Local Control Panel (Product Order Code:

Figure 26. Front Bezel Supporting the Standard Control Panel

®