Configuration Jumpers - Intel SR2600UR - Server System - 0 MB RAM Service Manual

Service guide
Hide thumbs Also See for SR2600UR - Server System - 0 MB RAM:
Table of Contents

Advertisement

Configuration Jumpers

BIOS Recover
J1D4
2
3
Password Clear
J1E8
2
3
BIOS Default
J1E7
2
3
BMC Force Update
J1H2
2
3
Jumper Name
A.
Serial Port Configuration
(J9A1)
B.
BMC Force Update
(J1H2)
C.
BIOS Default (J1E7)
20
E
Normal
Recover
D
Protect
Clear
C
Normal
Set
Default
B
Disable
Enable
If pins 1-2 are jumpered, the DCD to DTR mode is enabled. These
pins should be jumpered on 3-4 to operate in the DSR to DTR
(default) mode.
If pins 2-3 are jumpered, the Integrated BMC Force Update Mode is
enabled. These pins should be jumpered on 1-2 for normal system
operation.
If pins 2-3 are jumpered, the BIOS settings are cleared on the next
reset. These pins should be jumpered on 1-2 for normal operation.
Jumper Purpose
®
Intel
Server System SR2600UR/SR2625UR Service Guide
DCD to DTR
Serial Port
2
Configuration
3
4
J9A1
A
DSR to DTR
(factory default)
AF002832