Hold the server components (especially boards) only by the edges.
•
Place the server components on a grounded, static-free surface. Use a
conductive foam pad if available but not the component wrapper.
•
Do not slide the components over any surface.
Cooling and Airflow
CAUTION
For proper cooling and airflow, always install all access covers before
turning on the system. Operating the system for longer than five minutes
without the covers in place can cause overheating and damage to system
components.
Lifting and Moving
CAUTION
Do not attempt to lift or move the server by the handles on the power
supplies.
Equipment Rack Precautions
Follow the rack manufacturer's safety and installation instructions for proper rack installation. The
following additional rack safety installation measures shall be considered:
ANCHOR THE EQUIPMENT RACK
The equipment rack must be anchored to an unmovable suitable support to
prevent the rack from falling over when one or more systems are fully
extended out of the rack assembly. You must also consider the weight of any
other devices installed in the rack assembly. The equipment rack must be
installed according to the manufacturer's instructions.
MAIN AC POWER DISCONNECT
You are responsible for installing an AC power disconnect for the entire rack
unit. This main disconnect must be readily accessible, and it must be labeled
as controlling power to the entire unit, not just to the system(s).
GROUNDING THE RACK INSTALLATION
To avoid the potential for an electrical shock hazard, the rack assembly itself
must be suitably earth grounded, according to your local regional electrical
codes. This typically will require the rack to have its own separate earth
ground. We recommend you consult your local approved electrician.