7. Connect the two cables to the USB and control panel connectors on the back side of
the backplane as shown (see letter "B" in

Replacing a Fan Module

See the following sections:
"Replacing a Redundant Fan Module" on page 127
redundant fan module
"Replacing a Fixed Fan Module" on page 130
module

Replacing a Redundant Fan Module

To replace a redundant fan module, follow these steps:
1. Remove the PCI riser assembly. For instructions, see
Assembly" on page
2. Remove the processor air duct. For instructions, see
Duct" on page
3. Remove the large air baffle. For instructions, see
on page
4. Remove the fan baffle. For instructions, see
5. Remove the bridge board. For instructions, see step 5 in
Board" on page
6. Disconnect the fan cables from the midplane.
®
Intel
Server System SR2600UR/SR2625UR Service Guide
A

Figure 121. Installing Control Panel Module into the Server System

50.
56.
70.
102.
Figure
121).
B a c k p l a n
B
for instructions to replace a
for instructions to replace a fixed fan
"Removing the PCI Riser
"Removing the Processor Air
"Removing the Large Air Baffle"
"Removing the Fan Baffle" on page
"Removing the Midplane
e
AF003016
67.
127