System Environmental Specifications
The following table defines the system level operating and non-operating environmental
limits.
Temperature
Non-operating
Operating
Humidity
Non-operating
Shock
Operating
Packaged
Unpackaged
Vibration
Unpackaged
Acoustic noise
Electrostatic
discharge (ESD)
System Cooling
Requirement in
BTU/Hr
®
Intel
Server System SR2600UR/SR2625UR Service Guide
Table 6. System Environmental Specifications
-40°C to 70°C.
10°C to 35°C with the maximum rate of change not to exceed 10°C per
hour.
90% relative humidity (non-condensing) at 28°C.
2.0 g peak, 11 msec, half sine.
Non-palletized free fall in height 24 inches
Operational after an 18" free fall.
Trapezoidal, 25 g, velocity change 136 inches/sec.
5 Hz to 500 Hz, 2.20 g RMS random.
Sound Power: 7.0 BA in an idle state at typical office ambient temperature
(23 +/- 2°C).
+/-12 KV except I/O port +/- 8 KV per Intel Environment test specification.
2550 BTU/Hr
(>
40 lbs to < 80 lbs)
149