Server System SR2600UR/
SR2625UR Service Guide
®
A Guide for Technically Qualified Assemblers of Intel
Identified Subassemblies/
Products
Intel Order Number E51243-003

Advertisement

Table of Contents
loading

Summary of Contents for Intel SR2600UR - Server System - 0 MB RAM

  • Page 1 ® Intel Server System SR2600UR/ SR2625UR Service Guide ® A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products Intel Order Number E51243-003...
  • Page 2 Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur.
  • Page 3: Preface

    Preface About this Manual ® Thank you for purchasing and using the Intel Server System SR2600UR/SR2625UR. This manual is written for system technicians who are responsible for troubleshooting, upgrading, and repairing this server system. This document provides reference information, feature information, and step-by-step instructions for adding and replacing components in the server system.
  • Page 4 ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 5: Safety Information

    Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the ® Intel Server Deployment Toolkit 3.0 CD and/or at http://support.intel.com/support/motherboards/server/sb/cs-010770.htm.
  • Page 6 Some jumpers have a small tab on top that you can grip with your fingertips or with a pair of fine needle nosed pliers. If your jumpers do not have such a tab, ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 7 Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 8 ® viii Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 9: Table Of Contents

    Rear of Server System ......................29 Back Panel Connectors ....................30 SAS/SATA Midplanes ......................32 Passive Midplane ......................32 Active Midplane ......................33 ® Hot-Swap SAS/SATA Backplane (Intel Server System SR2600UR only) ......34 ® Hot-Swap SAS/SATA Backplane (Intel Server System SR2625UR only) ......36 ® Intel...
  • Page 10 RAID Support ........................37 Advanced Management Options ..................38 Intel® Remote Management Module 3 ............... 38 Rack Mount Options ......................38 Chapter 3: Hardware Installations and Upgrades ..........39 Before You Begin ........................ 39 Tools and Supplies Needed ..................39 System References ..................... 39 Cable Routing ........................
  • Page 11 Installing a Hot-swap SAS/SATA Hard Disk Drive ............74 Removing a Hot-swap SAS/SATA Hard Disk Drive ............76 ® Installing or Removing a Slimline Optical Drive or Internal USB Floppy (Intel Server System SR2600UR only) ......................77 Installing a Slimline Optical Drive or Internal USB Floppy ...........78 Removing a Slimline Optical Drive or Internal USB Floppy .........80...
  • Page 12 Replacing the Backup Battery ................... 119 Replacing the Power Supply ..................... 120 Replacing the Power Distribution Module ................. 122 ® Replacing the Control Panel (Intel Server System SR2600UR only) ......124 ® Replacing the Control Panel (Intel Server System SR2625UR only) ......125 Replacing a Fan Module ....................
  • Page 13 Zielbenutzer der Anwendung ..................197 Standortauswahl ......................197 Handhabung von Geräten ..................197 Warnungen zu Netzspannung und Elektrizität ............198 Warnhinweise für den Systemzugang ...............199 Warnhinweise für Racks ....................199 Elektrostatische Entladungen (ESD) .................200 Andere Gefahren .......................200 ® Intel Server System SR2600UR/SR2625UR Service Guide xiii...
  • Page 14 Advertencias de alimentacién y eléctricas ..............209 Advertencias sobre el cable de alimentación ............209 Advertencias el acceso al sistema ................210 Advertencias sobre el montaje en bastidor ............... 211 Descarga electrostática (ESD) .................. 211 Otros riesgos ......................212 ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 15 Figure 25. Connecting the Redundant Fan Power Cables to the Active Midplane Board..42 Figure 26. Front Bezel Supporting the Standard Control Panel ..........45 ® Figure 27. Front Bezel Supporting the Intel Local Control Panel .......... 46 Figure 28. Removing the Front Bezel..................46 Figure 29.
  • Page 16 Figure 85. Installing Power and Data Cables................94 Figure 86. Installing the Filler Panels..................95 Figure 87. Installing the Filler Panels..................96 Figure 88. Installing the I/O Expansion Module to the Server System........97 ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 17 Figure 99. Installing the SATA Cables .................. 106 Figure 100. Installing the Bridge Board into the Server System..........107 ® Figure 101. Removing the Backplane from the Intel Server System SR2600UR ....108 ® Figure 102. Removing the Backplane from the Intel Server System SR2625UR ....
  • Page 18 ® xviii Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 19: List Of Tables

    List of Tables Table 1. Server System References ..................4 ® Table 2. Intel Server System SR2600UR/SR2625UR Feature Summary ....... 9 Table 3. NIC LED Descriptions ....................31 Table 4. Setup Menu Key Use ....................139 Table 5. Power Supply Output Capability ................147 Table 6.
  • Page 20 ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 21: Chapter 1: Server System Contents And References

    ® The Intel Server System SR2600UR/SR2625UR ships with the Intel Server Board ® S5520UR. For information about the server board, see the Intel Server Board S5520UR Technical Product Specification. ® The contents of the Intel Server System SR2600UR/SR2625UR are listed below.
  • Page 22: Intel Server System Sr2600Urbrp/Sr2625Urbrp (Passive System) Contents

    • Intel System Management Software DVD ® Intel Server System SR2600URBRP/SR2625URBRP (Passive System) Contents ® Your Intel Server System SR2600URBRP/SR2625URBRP ships with the following items: ® • Intel Server Board S5520UR, installed in the server system • One 750-W power supply, installed in the server system •...
  • Page 23 Rack handles, in the hardware box • Attention document, in the server system product box • Quick Start User's Guide, in the server system product box ® • Intel Server Deployment Toolkit 3.0 CD ® • Intel System Management Software DVD ®...
  • Page 24: Additional Information And Software

    ® Intel Server System SR2625UR Quick Start User’s Guide Provided in the product box Accessories or other Intel Spares, Parts List and Configuration Guide server products Available at: http://support.intel.com/support/motherboards/server/s5520ur/ or by using the Server Configurator Tool Available at: http://serverconfigurator.intel.com/default.aspx...
  • Page 25 To make sure your system Power Budget Analysis Tool falls within the allowed Available at: power budget http://support.intel.com/support/motherboards/server/s5520ur/ ® For software to manage Intel System Management Software ® your Intel server Available at: http://www.intel.com/go/servermanagement/ ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 26 ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 27: Chapter 2: Server System Features

    Server System Features ® This chapter briefly describes the main features of the Intel Server System SR2600UR/ SR2625UR. This includes illustrations of the products, a list of the server system features, and diagrams showing the location of important components and connections on the server systems.
  • Page 28: Figure 2. Intel Server System Sr2625Ur

    AF002819 ® Figure 2. Intel Server System SR2625UR ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 29: Server System Feature Overview

    Support for one or two Intel Xeon processors in FC-LGA 1366 Socket B package with up to 95 W Thermal Design Power (TDP) • ® 4.8 GT/s, 5.86 GT/s and 6.4 GT/s Intel QuickPath ® Interconnect (Intel QPI) • EVRD11.1 For a complete list of supported processors, see http://support.intel.com/support/motherboards/server/s5520ur/...
  • Page 30: Table 2. Intel Server System Sr2600Ur/Sr2625Ur Feature Summary

    One DH-10 serial Port B header • Six Serial ATA II connectors • Two I/O module connectors • ® One RMM3 connector to support an optional Intel Remote Management Module 3 • SATA Software RAID 5 Activation Key connector • One SSI-EEB-compliant front panel header •...
  • Page 31: Server System Components

    ® Table 2. Intel Server System SR2600UR/SR2625UR Feature Summary Feature Description • Control Panel Standard control panel • ® Intel Local Control Panel LEDs and displays With standard control panel: • NIC1 Activity • NIC2 Activity • Power / Sleep •...
  • Page 32: Intel Server System Sr2600Ur Components

    2.5 inch Hard Drives (optional) Riser Card Assembly Hard Drive Bays Integrated Chassis Intrusion Switch Slimline Optical Drive Bay Processor Air Duct Figure 3. Intel Server System SR2600UR Components ® ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 33: Intel Server System Sr2625Ur Components

    Flex Bay - Two additional 2.5 Hard Drives or Tape Drive (optional) Integrated Chassis Intrusion Switch M. Slimline Optical Drive Bay Processor Air Duct Hard Drive Bays Figure 4. Intel ® Server System SR2625UR Components ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 34: Intel Light-Guided Diagnostics

    ® Intel Light-Guided Diagnostics The server system contains the following diagnostic LEDs, each providing the following functions: • The System Status LED on the front and back panels (see Figure 5 Figure shows the overall health of the system (green, blinking green, blinking amber, amber, off) .
  • Page 35: Figure 5. Intel ® Light-Guided Diagnostic Leds - Server Board

    CPU 1 DIMM Fault LEDs CPU 2 Fan Fault LED Memory 2 Fan Fault LED CPU 2 DIMM Fault LEDs 5V Standby LED ® Figure 5. Intel Light-Guided Diagnostic LEDs - Server Board ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 36: Figure 6. Intel Light-Guided Diagnostic Leds - Passive Midplane

    AF003043 ® Figure 6. Intel Light-Guided Diagnostic LEDs - Passive Midplane AF003042 Fan 2 Fault LED Fan 3 Fault LED Fan 4 Fault LED Fan 5 Fault LED Fan 6 Fault LED Fan 1 Fault LED ® Figure 7. Intel Light-Guided Diagnostic LEDs - Active Midplane ®...
  • Page 37: Figure 8. Intel Light-Guided Diagnostic Leds - Standard Control Panel

    AF003002 Status LED System Identification LED ® Figure 8. Intel Light-Guided Diagnostic LEDs - Standard Control Panel ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 38: Server Board Components

    Server Board Components This section helps you identify the components and connectors on the server board. AF002696 ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 39: Figure 9. Server Board Connector And Component Locations

    Processor 1 DIMM slots Processor 2 DIMM slots Processor 2 Socket ® M. CPU 2 Fan Header Memory 2 Fan Header Bridge Board Connector (Intel Server Chassis) Front Panel Connector Fan Board Connector 2x4 Power Connector Main Power Connector Power Supply SMBus...
  • Page 40: Configuration Jumpers

    These pins should be jumpered on 1-2 for normal system operation. BIOS Default (J1E7) If pins 2-3 are jumpered, the BIOS settings are cleared on the next reset. These pins should be jumpered on 1-2 for normal operation. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 41: Server System Sr2600Ur

    BIOS image. The main system BIOS will not boot. These pins should be jumpered on 1-2 for normal system operation. Figure 10. Configuration Jumpers ® Front of Intel Server System SR2600UR Peripheral Devices ® The Intel Server System SR2600UR provides locations and hardware for installing hard drives, a tape drive, a USB floppy drive, CD-ROM drive, or DVD-ROM drive.
  • Page 42: Slimline Optical Drive Carrier

    “Installing or Removing a Slimline Optical ® Drive or Internal USB Floppy (Intel Server System SR2600UR only)” on page To use one of the drives provided by Intel, use the following order codes: • Slimline DVD-ROM Drive: AXXSATADVDROM • Slimline DVD-RW Drive: AXXSATADVDRWROM ®...
  • Page 43: Control Panel

    For instructions on installing the drives, see the following sections: • “Installing a Tape Drive” on page 84 ® • “Installing a Sixth Hard Disk Drive (Intel Server System SR2600UR only)” on page 86 • “Installing the 2.5 Inch Fixed Hard Disk Drives” on page 90 Control Panel ®...
  • Page 44: Figure 12. Standard Control Panel

    The front and rear video ports cannot be used at the same time. Figure 12. Standard Control Panel ® Intel Local Control Panel ® The following diagram shows the features available on the Intel Local Control Panel. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 45 No light indicates POST is running or the system is off. NIC 2 Activity LED Continuous green light indicates a link between the system and the network to which it is connected. NIC 1 Activity LED Blinking green light indicates network activity. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 46: Bezels

    The optional front bezels are made of molded plastic and provide a snap-on design that allows for maximum airflow through the server system. Separate bezels are available to ® support systems that have either the Standard control panel or Intel Local Control Panel installed.
  • Page 47: Server System Sr2625Ur

    The server system ships with eight drive carriers for installing eight SAS or Serial ATA (SATA) hot-swap 2.5 inch drives. ® Note: SAS drives are only supported on the Intel Server System SR2625URLX (active version). For instructions on installing hard drives, see “Installing a Hot-swap SAS/SATA Hard...
  • Page 48: Control Panel

    For instructions on installing an optical drive, see “Installing a Slimline Optical Drive” on page To use one of the drives provided by Intel, use the following order codes: • Slimline DVD-ROM Drive: AXXSATADVDROM •...
  • Page 49: Bezels

    Upper Power Receptacle USB 5 Lower Power Receptacle M. DB-9 Serial B Connector Lower Power Supply Module Video ® Intel I/O Expansion Module (Optional) RJ-45 Serial A Connector ® Intel Remote Management Module NIC (Optional) Figure 15. Server System Back Panel ®...
  • Page 50: Back Panel Connectors

    Back Panel Connectors AF002879 Mouse Keyboard Serial Port B (RJ-45) NIC 1 (10/100/1000 Mb) NIC 2 (10/100/1000 Mb) Video USB Port 6 USB Port 5 Figure 16. Back Panel Connectors ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 51: Table 3. Nic Led Descriptions

    No network connection Solid Amber Network connection in place Blinking Amber Transmit/receive activity Right 10 Mbps connection (if left LED is on or blinking) Solid Amber 100 Mbps connection Solid Green 1000 Mbps connection ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 52: Sas/Sata Midplanes

    SATA 0-7 Connectors Fan 2 Power Connector Bridge Board Connector Backplane Connectors Figure 17. Passive Midplane Components ® Note: SATA connectors 6 and 7 are not used in the Intel Server System SR2600UR/SR2625UR. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 53: Active Midplane

    Mini-DIMM Connector Fan 1 Power Connector Fan 6 Power Connector Fan 2 Power Connector Fan 5 Power Connector RAID Activation Key Connector Bridge Board Connector Backplane Connectors Figure 18. Active SAS/SATA RAID Midplane Components ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 54: Hot-Swap Sas/Sata Backplane (Intel Server System Sr2600Ur Only)

    ® Hot-Swap SAS/SATA Backplane (Intel Server System SR2600UR only) The backplane serves as an interface between the midplane board and the system drives. The following diagrams show the location for each connector found on the backplane. AF000045 Slimline Interposer Card Connector...
  • Page 55: Figure 20. Hot-Swap Sas/Sata Backplane Components (Rear View)

    Power Connector (for sixth hard drive or Power Connector tape drive or 2.5 inch fixed drives) SAS/SATA Connector (for sixth hard drive Midplane Connectors or SATA tape drive) Figure 20. Hot-Swap SAS/SATA Backplane Components (Rear View) ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 56: Hot-Swap Sas/Sata Backplane (Intel Server System Sr2625Ur Only)

    ® Hot-Swap SAS/SATA Backplane (Intel Server System SR2625UR only) The backplane serves as an interface between the midplane board and the system drives. The following diagrams show the location for each connector found on the backplane. AF002788 SAS/SATA Hot-swap Connectors Slimline Optical Drive Connector Figure 21.
  • Page 57: Raid Support

    ® or “Configure SATA as RAID”. The Intel Embedded Server RAID Technology II is ® enabled by the “Configure SATA as RAID” option. The Intel Embedded Server RAID Technology II feature provides RAID modes 0, 1, and 10. ® Intel...
  • Page 58: Advanced Management Options

    To enable RAID 5, this activation key is placed on the SATA Key connector that ® is located at the left side of the server board. For information on installing the Intel RAID Activation Key AXXRAKSW5 accessory to enable RAID 5, see “Installing the...
  • Page 59: Chapter 3: Hardware Installations And Upgrades

    All references to left, right, front, top, and bottom assume the reader is facing the front of the server system as it would be positioned for normal operation. ® Note: If the procedure for servicing a particular component is identical for both Intel Server ®...
  • Page 60: Cable Routing

    Use caution to make sure no cables or wires are pinched and that the airflow from the fans is not blocked. Use the figures below to determine the correct cable routing. Intel® Remote Management Module 3 (optional) Server Board...
  • Page 61: Fan Connections

    Fan Connections Use the figures below to determine the proper fan connections. AF003109 Figure 24. Connecting the Non-redundant Fan Power Cables to the Passive Midplane Board ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 62: Removing And Installing From A Rack

    Figure 25. Connecting the Redundant Fan Power Cables to the Active Midplane Board Removing and Installing from a Rack ® ® To install the Intel Server System SR2600UR/SR2625UR in a rack, three Intel rack options are available: • Fixed mount relay rack / cabinet mount kit This rack option requires the system to be removed from the rack before servicing.
  • Page 63: Fixed Bracket Rack Mount Installation

    19. Slide the middle rail toward the front until the rear bracket area is accessible. 20. Attach the rear end of the outer rail to the rear bracket with at least one screw. If possible, attach at two places. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 64: Basic Slide Rail Rack Mount Removal

    8. Align the inner rails (attached to the server chassis) with the outer rail assemblies (attached to the rack). 9. Engage the matching rails and slide the server chassis into the rack until the two safety stops lock into position. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 65: Tool-Less Full Extracting Slide Rail Rack Mount Servicing

    Note: Beware of cables when re-installing the system into the rack so that the cables do not get pulled or interfered with. Removing and Installing the Front Bezel ® The front bezels are available as optional accessories for the Intel Server System SR2600UR/SR2625UR. The following front bezel options are available: •...
  • Page 66: Removing The Front Bezel

    AF000153 ® Figure 27. Front Bezel Supporting the Intel Local Control Panel Removing the Front Bezel If your system includes a front bezel, follow these steps to remove the front bezel: 1. Unlock the bezel (if locked). 2. Pull the bezel from the server system.
  • Page 67: Installing The Front Bezel

    The front bezel is optional. If your system includes the bezel for either the standard ® control panel or Intel Local Control Panel, follow these steps to install the front bezel. Note: Before installing the bezel, you must install the rack handles. For instructions, see “Installing the Rack Handles”...
  • Page 68: Removing And Installing The System Cover

    30), slide the top cover back until it stops (see letter "C" in Figure 30). 3. Insert your finger in the notch (see letter “D” in Figure 30) and lift the cover upward to remove it. AF002954 Figure 30. Removing the Server System Cover ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 69: Installing The Server System Cover

    2. Slide the cover forward until it clicks into place (see letter “A” in Figure 31). 3. (Optional) Insert the safety screw at the center of the top cover (see letter “B” in Figure 31), if required. AF002955 Figure 31. Installing the Server System Cover ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 70: Removing And Installing The Pci Riser Assembly

    — If you need to add or replace a PCI riser card, see “Replacing a PCI Riser Card” on page — If you removed the PCI riser assembly for another procedure, continue with that procedure. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 71: Installing The Pci Riser Assembly

    The riser cards will seat into the matching sockets on the server board. 4. Connect any cables to add-in cards that require them. See your add-in card documentation for information and add-in card requirements. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 72: Replacing A Pci Riser Card

    Figure 34. Removing the PCI Riser Card from the Server System (Full-height Side) 6. Install the replacement riser card, if desired. For instructions, see “Installing PCI Riser Card into the Server System” on page ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 73: Installing A Pci Riser Card

    8. Install the PCI add-in card(s), if desired. For instructions, see “Installing a PCI Add-in Card” on page 9. Install the PCI riser assembly into the server system. For instructions, see “Installing the PCI Riser Assembly” on page ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 74: Installing And Removing A Pci Add-In Card

    6. Close the rear retention clip. Push the blue slide upward and press the clip to lock it into place. 7. Close the front retention clip and push the blue latch forward to lock it into place. Note: Make sure that all empty add-in card slots have filler panels installed. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 75: Removing A Pci Add-In Card

    Note: Make sure that all empty add-in card slots have filler panels installed. 8. Install the PCI riser assembly into the server system. For instructions, see “Installing the PCI Riser Assembly” on page ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 76: Removing And Installing The Processor Air Duct

    1. Remove the PCI riser assembly. For instructions, see “Removing the PCI Riser Assembly” on page 2. Lift the processor air duct from its location over the two processor sockets. AF002956 Figure 38. Removing the Processor Air Duct ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 77: Installing The Processor Air Duct

    DIMM or DIMM blank installed. You may store extra DIMM blanks in any of the unused CPU 1 DIMM slots. For additional information regarding memory requirements and options, refer to the following documents: ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 78: Installing Dimms

    ® • Intel Server System SR2600UR Technical Product Specification ® • Intel Server System SR2625UR Technical Product Specification For a web link to the list of tested DIMMs, see “Additional Information and Software” on page Installing DIMMs To install DIMMs, follow these steps: 1.
  • Page 79: Removing Dimms

    Caution: Protective socket cover needs to be removed for proper cooling of the processor; failure to remove the cover could result in damage to the system. Installing the Processor To install the processor, follow these steps: ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 80: Figure 41. Lifting The Processor Socket Handle

    Note: Do not touch the orientation posts on the socket; they are very sensitive and easily damaged. Note: Retain the protective socket cover for use when removing a processor that will not be replaced. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 81: Figure 43. Removing The Protective Socket Cover

    11. Orient the processor with the socket such that the orientation notches on the processor align with the two orientation posts on the socket, and insert the processor into the socket (see Figure 45). ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 82: Installing The Heatsink(S)

    Note: New unused heatsinks have adequate TIM on the bottom. If you are reusing a heatsink from replacing a processor, make sure there is adequate TIM present on the heatsink to support processor cooling. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 83: Figure 47. Installing The Heatsink (Passive Heatsink Shown)

    Repeat steps 4a through 4c by giving each screw two rotations each time until all screws are lightly tightened upto a maximum of 8 inch-lbs torque. AF002841 Figure 47. Installing the Heatsink (Passive Heatsink Shown) ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 84: Removing The Heatsink

    Lift the heatsink from the processor. If it does not pull up easily, twist the heatsink again. Do not force the heatsink from the processor. Doing so could damage the processor. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 85: Removing The Processor

    6. Open the CPU load plate (see Figure 42). 7. Remove the processor. 8. If you want to replace the processor, see “Installing the Processor” on page Otherwise, install the protective socket cover over the empty processor socket. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 86: Removing And Installing The Small Air Baffle

    ® Removing and Installing the Small Air Baffle (Intel Server System SR2600UR only) Some installation processes require that you remove the small air baffle that is placed behind the hard drive bays, near the front of your server. The following sections describe how to remove and then install the small air baffle.
  • Page 87: Removing And Installing The Fan Baffle

    - the arrow is pointing to the hook in the baffle). 2. Slide the baffle out in the direction shown (see letter “B” in Figure 51). 3. Pull up on it (see letter “C” in Figure 51). ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 88: Figure 51. Removing The Fan Baffle

    AF003021 Figure 51. Removing the Fan Baffle ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 89: Installing The Fan Baffle

    3. Install the baffle making sure the hook on the front of the baffle is inserted into the corresponding hole in the backplane board (see letter “C” in Figure 52 - the arrow is pointing to the hole in the backplane board). AF003022 Figure 52. Installing the Fan Baffle ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 90: Removing And Installing The Large Air Baffle

    2. While setting the baffle into place, route the cables beneath it appropriately. For help in determining where the cables should be routed, see “Cable Routing” on page 40 or the Quick Reference Label that came with your system. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 91: Installing And Removing A Hot-Swap Hard Drive

    “Additional Information and Software” on page Installing a SAS or SATA Hot-swap Hard Disk Drive ® To install a SAS or SATA hot-swap hard disk drive in Intel Server System SR2600UR, follow these steps: 1. Press the green latch towards the black lever and pull out on the lever to release the hard drive carrier (see letter "A"...
  • Page 92: Figure 55. Removing Hot-Swap Disk Carrier From The Server System

    7. Align the holes in the drive to the holes in the drive carrier and attach it to the carrier with the screws that were attached to the plastic retention device (see Figure 57). ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 93: Figure 57. Installing Hard Drive Into Carrier

    (see letter “A” in Figure 58). 9. Close the lever to lock the drive assembly into place (see letter “B” in Figure 58). AF002946 Figure 58. Install Drive Assembly into the Server System ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 94: Removing A Sas Or Sata Hot-Swap Hard Disk Drive

    Removing a SAS or SATA Hot-swap Hard Disk Drive ® To remove a SAS or SATA hot-swap hard disk drive from Intel Server System SR2600UR, follow these steps: 1. Press the green latch towards the black lever and pull out on the lever to release the the hard drive carrier.
  • Page 95: Figure 59. Removing Hot-Swap Disk Carrier From The Server System

    7. Align the holes in the drive to the holes in the drive carrier and attach it to the carrier using the four screws that were attached to the plastic retention device (see letter “B” in Figure 61). ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 96: Removing A Hot-Swap Sas/Sata Hard Disk Drive

    Figure 62. Installing Drive Assemby into the Server System Removing a Hot-swap SAS/SATA Hard Disk Drive ® To remove a hot-swap SAS/SATA hard disk drive from Intel Server System SR2625UR, follow these steps: 1. Press in on the green latch at the front of the hard drive carrier.
  • Page 97: Installing Or Removing A Slimline Optical Drive Or Internal Usb Floppy (Intel Sr2600Ur Only)

    6. Close the lever to lock the drive assembly into place. Installing or Removing a Slimline Optical Drive or ® Internal USB Floppy (Intel Server System SR2600UR only) Cautions: The slimline optical drive is NOT hot-swappable. Before removing or replacing the drive,...
  • Page 98: Installing A Slimline Optical Drive Or Internal Usb Floppy

    Installing a Slimline Optical Drive or Internal USB Floppy ® To install a slimline optical drive or internal USB floppy in Intel Server System SR2600UR, follow these steps: 1. Remove the empty tray and screw from the accessory kit box and obtain the optical device.
  • Page 99: Figure 65. Securing The Interposer Board To The Device Tray

    USB connector (see letter “C” in Figure 66) and refer to the documentation that came with the device. Connector Interposer Board Release Lever AF002965 Figure 66. Installing an Optical Drive Assembly into the Server System ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 100: Removing A Slimline Optical Drive Or Internal Usb Floppy

    Removing a Slimline Optical Drive or Internal USB Floppy ® To remove a slimline optical drive or internal USB floppy from Intel Server System SR2600UR, follow these steps: 1. If removing an internal USB floppy, unplug it from the backplane.
  • Page 101: Figure 68. Removing The Slimline Optical Drive From The Tray

    Figure 68. Removing the Slimline Optical Drive from the Tray 5. If no device will be installed in this location, install a filler blank as shown in Figure AF000155 Figure 69. Installing Filler Blank into the Server System ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 102: Installing Or Removing A Slimline Optical Drive

    ® Installing or Removing a Slimline Optical Drive (Intel Server System SR2625UR only) Cautions: The slimline optical drive is NOT hot-swappable. Before removing or replacing the drive, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet.
  • Page 103: Removing A Slimline Optical Drive

    Figure 71. Installing an Optical Drive into the Server System Removing a Slimline Optical Drive ® To remove the slimline optical drive from Intel Server System SR2625UR, follow these steps: 1. Press in on the plastic guide at the rear of the optical drive (see letter “A” in...
  • Page 104: Installing A Tape Drive

    3. If no device will be installed in this location, install a filler blank in this location. Installing a Tape Drive ® To install a tape drive into Intel Server System SR2600UR/SR2625UR, your system must meet the following requirements: •...
  • Page 105: Figure 73. Removing Tape Drive Filler Panel From The Server System

    Figure 74. Inserting a Tape Drive into the Carrier 3. Slide the tape drive carrier with the installed tape drive into the combined tape drive bay/sixth drive bay until the carrier clicks into place. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 106: Server System Sr2600Ur Only)

    Installing a Sixth Hard Disk Drive (Intel Server System SR2600UR only) ® To install a sixth hard disk drive into Intel Server System SR2600UR/SR2625UR, your system must meet the following requirements: • You must purchase the sixth SAS/SATA Hard Disk Drive (HDD) kit, order number ASR2500SIXDRV.
  • Page 107: Figure 76. Removing The Filler Panel

    (see letter “B” in Figure AF003029 Figure 76. Removing the Filler Panel 2. Install the sixth hard drive filler panel as shown in Figure AF003032 Figure 77. Installing Sixth Hard Drive Filler Panel ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 108: Figure 78. Installing Sixth Hdd Bracket

    Install one end of the short SATA cable to the SATA connector on the backplane. c. Install the other end of the short SATA cable to the SATA connector on the sixth HDD board (see letter “B” in Figure 79). ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 109: Figure 79. Installing Power And Sata Cables (Active Midplane Installed)

    80) and route the cable through the air baffle (see letter “C” in Figure 80). c. Connect the other end of the cable (labeled SERVER BOARD) to the SATA5 connector on the server board (see letter “D” in Figure 80). ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 110: Installing A Sixth Hard Disk Drive

    SAS or SATA Hot-swap Hard Disk Drive” on page Installing the 2.5 Inch Fixed Hard Disk Drives ® To install the 2.5 inch fixed hard disk drives into Intel Server System SR2600UR/ SR2625UR, your system must meet the following requirements: •...
  • Page 111: Figure 81. Removing The Filler Panel

    2. Insert each 2.5 inch hard disk drive into the drive cage (see letter “A” in Figure and atach using four screws (see letter “B” in Figure 82). AF003035 Figure 82. Attaching the 2.5 inch HDDs to the drive cage ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 112: Figure 83. Attaching The 2.5 Inch Hdd Assembly To The Filler Panel

    2.5 inch fixed hard disk drive kit as shown in Figure AF003036 Figure 83. Attaching the 2.5 inch HDD assembly to the filler panel ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 113: Figure 84. Installing The 2.5 Inch Fixed Hdd Assembly

    Figure 85). 7. Connect one end of the data cables to the SATA connectors on the server board (see letter “C” in Figure 85) or SAS/SATA connectors on an SAS/SATA add-in PCI card. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 114: Filling Empty Server System Bays

    8. Connect the other end of the data cables to the two hard disk drives (see letter “D” Figure 85). AF003038 Figure 85. Installing Power and Data Cables ® Filling Empty Server System Bays (Intel Server System SR2600UR only) ® In the Intel Server System SR2600UR, you must install either a filler panel, drive blank, or empty drive carrier into an empty drive bay.
  • Page 115: Server System Sr2625Ur Only)

    • Install empty hard drive carriers into any remaining empty hard drive bays. AF003030 Figure 86. Installing the Filler Panels ® Filling Empty Server System Bays (Intel Server System SR2625UR only) ® In the Intel Server System SR2625UR, you must install either a filler panel, drive blank, or empty drive carrier into an empty drive bay.
  • Page 116: Installing And Removing The I/O Expansion Module

    Note: For the 1-socket expansion module, install the three standoffs shown in gray. For the 2- scoket expansion module, also install the fourth standoff shown in red. 5. Position the I/O expansion module over the server board as shown in Figure ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 117: Removing The I/O Expansion Module

    3. Disconnect the I/O expansion module from the server board connector and the standoffs and remove the module out of the server system (see letter “A” in Figure 4. Remove the standoffs from the server board (see letter “B” in Figure 89). ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 118: Installing And Removing The Intel

    “Installing the Processor Air Duct” on page 7. Install the PCI riser assembly into the server system. For instructions, see “Installing the PCI Riser Assembly” on page ® Installing and Removing the Intel Remote Management Module 3 ® Installing the Intel RMM3 ®...
  • Page 119: Figure 90. Removing The Intel ® Rmm3 Filler Panel

    ® 3. Squeeze the sides of the Intel RMM3 filler panel to disengage it from the server system back panel and remove it (see Figure 90). AF003008 ® Figure 90. Removing the Intel RMM3 filler panel ® 4. Attach the Intel...
  • Page 120: Figure 92. Connecting The Intel ® Rmm3 Cable

    AF002949 ® Figure 92. Connecting the Intel RMM3 cable 6. Connect the opposite end of the cable to the RMM3 connector on the server board (see letter “A” in Figure 93). 7. Attach the module bracket to the chassis with two screws (see letter “B” in Figure 93).
  • Page 121: Rmm3

    ® Removing the Intel RMM3 ® To remove the Intel Remote Management Module 3, follow these steps: 1. Remove the PCI riser assembly. For instructions, see “Removing the PCI Riser Assembly” on page 2. Remove the processor air duct. For instructions, see “Removing the Processor Air...
  • Page 122: Replacing The Midplane Board

    RMM3 filler panel into the system back panel (see Figure 95). AF003011 ® Figure 95. Installing the Intel RMM3 filler panel 6. Install the processor air duct. For instructions, see “Installing the Processor Air Duct” on page 7. Install the PCI riser assembly into the server system. For instructions, see “Installing the PCI Riser Assembly”...
  • Page 123: Figure 96. Removing The Bridge Board From The Server System

    “Replacing a Fan Module” on page 127. 7. Hold the midplane board only by the edges and slide the midplane board in the direction shown to release it from the backplane (see letter “A” in Figure 97). ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 124: Installing The Midplane Board

    1. Position the midplane board over the retention pins (see letter “A” in Figure 98). 2. Align the four holes on the midplane with the four standoffs on the chassis and press down uniformly until it clicks into place (see letter “B” in Figure 98). ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 125: Figure 98. Installing The Midplane Into The Server System

    (see letter “C” in Figure 98). AF002973 Figure 98. Installing the Midplane into the Server System 4. Connect cables as necessary to the midplane board. 5. Passive midplane only: Do the following: ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 126: Figure 99. Installing The Sata Cables

    Slide the bridge board through the fan assembly (see letter “B” in Figure 100). c. Insert the bridge board into the bridge board connector on the midplane and server board (see letter “C” in Figure 100). ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 127: Replacing The Backplane

    1. Remove the midplane board. For instructions, see “Removing the Midplane Board” on page 102. Note: To prevent damage to your system, you must ensure the midplane is completely removed before attempting to remove the backplane. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 128: Figure 101. Removing The Backplane From The Intel Server System Sr2600Ur

    Figure 101. AF002992 ® Figure 101. Removing the Backplane from the Intel Server System SR2600UR ® For Intel Server System SR2625UR, do the following: a. Remove the blue thumbscrew from the backplane board (see letter “A” in Figure 102).
  • Page 129: Installing The Backplane

    AF003110 ® Figure 102. Removing the Backplane from the Intel Server System SR2625UR Installing the Backplane To install the backplane, follow these steps: 1. Remove the midplane board. For instructions, see “Removing the Midplane Board” on page 102. 2. Remove all hot-swap drive carriers, regardless of whether or not a drive is installed in the carrier.
  • Page 130: Figure 103. Installing The Backplane Into The Intel Server System Sr2600Ur

    “B” in Figure 103). AF002975 ® Figure 103. Installing the Backplane into the Intel Server System SR2600UR ® For Intel Server System SR2625UR, do the following: a. Hold the backplane only by the edges. Do not push or pull on any components on the backplane.
  • Page 131: Installing And Removing The Raid Activation Key And The Raid Mini-Dimm (Active Systems Only)

    AF003111 ® Figure 104. Installing the Backplane in the Intel Server System SR2625UR 4. Install hot-swap drive carriers. For instructions, see “Installing a SAS or SATA Hot-swap Hard Disk Drive” on page 5. Install the midplane board. For instructions, see “Installing the Midplane Board”...
  • Page 132: Removing The Raid Activation Key And The Raid Mini-Dimm

    Push firmly on the DIMM until it snaps into place and both levers close. Open Levers RAID Mini DIMM Socket RAID ® Intel RAID Activation Key Socket AF002976 Figure 105. Installing the RAID Activation Key and the RAID Mini-DIMM 6.
  • Page 133: Figure 106. Removing The Raid Activation Key And The Raid Mini Dimm

    Figure 106).. Open Levers RAID Mini DIMM Socket RAID ® Intel RAID Activation Key Socket AF002977 Figure 106. Removing the RAID Activation Key and the RAID Mini DIMM 6. Install the large air baffle. For instructions, see “Installing the Large Air Baffle” on page 7.
  • Page 134: Installing And Removing The Raid Battery Backup Unit (Active Systems Only)

    (see letter “C” in Figure 107). 7. Connect the cable from the rear of the RAID battery backup unit to the midplane board (see letter “D” in Figure 107). ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 135: Removing The Raid Battery Backup Unit

    4. Remove the cable from the rear of the RAID battery backup unit and the midplane board (see letter “A” in Figure 108). 5. Slide the RAID battery backup unit away from the power supply and lift from the server system (see letter “B” in Figure 108). ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 136: Installing And Removing The Server Board

    5. Remove the fan module assembly. For instructions, see “Replacing a Fan Module” on page 127. 6. Remove the I/O expansion module, if installed. For instructions, see “Removing the I/O Expansion Module” on page ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 137: Figure 109. Removing The Server Board

    ® ® 7. Remove the Intel RMM3, if installed. For instructions, see “Removing the Intel RMM3” on page 101. 8. Disconnect all cables from the server board. 9. Remove memory. For instructions, see “Removing DIMMs” on page 10. Remove the processor heatsink(s) and processor(s). For instructions, see “Removing the Heatsink”...
  • Page 138: Installing The Server Board

    8. Install the large air baffle. For instructions, see “Installing the Large Air Baffle” on page 9. Install the bridge board. For instructions, see step 6 in “Installing the Midplane Board” on page 104. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 139: Replacing The Backup Battery

    10. If necessary, install the I/O expansion module. For instructions, see “Installing the I/O Expansion Module” on page ® ® 11. If necessary, install the Intel RMM3. For instructions, see “Installing the Intel RMM3” on page 12. Connect all additional cables to the server board as necessary.
  • Page 140: Replacing The Power Supply

    The power supply can be replaced if it fails or if one of the fans that is integrated into it fails. To replace the power supply, follow these steps: 1. Do one of the following: ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 141: Figure 112. Removing Power Supply Filler Panel From The Server System

    — Insert the replacement power supply module into the power supply cage and push all the way until it clicks into place. AF000024 Figure 114. Installing Power Supply Module into the Server System ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 142: Replacing The Power Distribution Module

    6. Remove the hot-swap power supply/supplies. For instructions, see step 1 in “Replacing the Power Supply” on page 120. 7. Remove the two screws to release the module (see letter “A” in Figure 116). ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 143: Figure 116. Removing The Power Distribution Module

    14. Install the processor air duct. For instructions, see “Installing the Processor Air Duct” on page 15. Install the PCI riser assembly. For instructions, see “Installing the PCI Riser Assembly” on page ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 144: Replacing The Control Panel (Intel Server System Sr2600Ur Only)

    ® Replacing the Control Panel (Intel Server System SR2600UR only) ® The steps for replacing the standard control panel and the Intel Local Control Panel in ® Intel Server System SR2600UR are nearly identical. Use this procedure for both varieties of the control panel. Where necessary, differences between the two control panels are noted.
  • Page 145: Replacing The Control Panel (Intel ® Server System Sr2625Ur Only)

    ® Replacing the Control Panel (Intel Server System SR2625UR only) ® The steps for replacing the standard control panel and the Intel Local Control Panel in ® Intel Server System SR2625UR are nearly identical. Use the following steps for both varieties of the control panel.
  • Page 146: Figure 119. Removing Standard Control Panel Module From The Server System

    120). Data Cable Cable AF003015 Figure 120. Connecting the Control Panel Cables 6. Slide the replacement control panel into the server system (see letter “A” in Figure 121) until it clicks into place. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 147: Replacing A Fan Module

    4. Remove the fan baffle. For instructions, see “Removing the Fan Baffle” on page 5. Remove the bridge board. For instructions, see step 5 in “Removing the Midplane Board” on page 102. 6. Disconnect the fan cables from the midplane. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 148: Figure 122. Removing The Redundant Fan Module

    Lower the fan assembly into the chassis (see letter “A” in Figure 123). b. Line up the pins on the chassis floor with the matching holes on the bottom of the fan assembly (see letter “B” in Figure 123). ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 149: Figure 123. Installing The Redundant Fan Module

    70. Re-route cables through the air baffle as necessary. 12. Install the fan baffle. For instructions, see “Installing the Fan Baffle” on page 13. Install the processor air duct. For instructions, see “Installing the Processor Air Duct” on page ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 150: Replacing A Fixed Fan Module

    4. Remove the fan baffle. For instructions, see “Removing the Fan Baffle” on page 5. Remove the bridge board. For instructions, see step 5 in “Removing the Midplane Board” on page 102. 6. Disconnect the fan cables from the midplane. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 151: Figure 124. Removing The Fixed Fan Module

    Lower the fan assembly into the chassis (see letter “A” in Figure 125). b. Line up the pins on the chassis floor with the matching holes on the bottom of the fan assembly (see letter “B” in Figure 125). ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 152: Figure 125. Installing The Fixed Fan Module

    “Installing the Large Air Baffle” on page 12. Install the fan baffle. For instructions, see “Installing the Fan Baffle” on page 13. Install the processor air duct. For instructions, see “Installing the Processor Air Duct” on page ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 153: Replacing A System Fan

    1. Grasp the failed fan and lift straight up to remove it from the module (see Figure 126). Figure 126. Removing a Fan from the Redundant Fan Module 2. Position the replacement fan so the connector on the fan is at the right and pointing down. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 154: Replacing A Fixed Fan

    The system fans at the front of the server system can be individually replaced if one of them fails. To replace a fan, follow these steps: ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 155: Figure 128. Removing A Fan From The Fixed Fan Module

    3. Remove the fan from the fan module (see letter “B” in Figure 128). AF003027 Figure 128. Removing a Fan from the Fixed Fan Module 4. Position the replacement fan so the connector on the fan is at the right and pointing down. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 156: Installing And Removing The Rack Handles

    Installing the Rack Handles Align the rack handle with the two holes on the side of the server system and attach the rack handle to the server system with two screws as shown in Figure 130. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 157: Removing The Rack Handles

    Removing the Rack Handles Remove the two screws holding the rack handle in place, and remove the rack handle from the server system as shown in Figure 131. AF000020 Figure 131. Removing the Rack Handle ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 158 ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 159: Chapter 4: Server Utilities

    You can run the BIOS Setup with or without an operating system ® being present. For information about specific BIOS setup screens, see the Intel Server Board S5520UR Technical Product Specification. For a web link to this document, see “Additional Information and Software”...
  • Page 160 If "No" is selected and the <Enter> key is pressed, or if the <Esc> key is pressed, you are returned to the screen you were in before <F9> was pressed without affecting any existing field values. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 161: Upgrading The Bios

    Recording the Current BIOS Settings 1. Boot the computer and press <F2> when you see the message: Press <F2> Key if you want to run SETUP 2. Write down the current settings in the BIOS Setup program. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 162: Upgrading The Bios

    3. Locate the Password Clear jumper block at board position J1E8. 4. Move the jumper from the normal operation position, that is, Password Clear Protect position (covering pins 1 and 2) to the Password Clear Erase position (covering pins 2 and 3). ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 163: Figure 132. Password Clear Jumper

    6. Move the Password Clear jumper back to the Password Clear Protect position (covering pins 1 and 2). 7. Close the server system. 8. Power up the server. The password is now cleared and can be reset by going into the BIOS setup. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 164: Restoring The Bios Defaults

    Figure 133. BIOS Default Jumper 5. Wait five seconds. 6. Return the BIOS Default jumper to the normal position (covering pins 1 and 2). 7. Close the server system. 8. Power up the system. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 165 The BIOS defaults settings are now restored and can be reset by going into the BIOS setup. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 166 ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 167: Appendix A: Technical Reference

    +3.3 V 110% (= 26.4 A) 150% (= 36 A) +5.0 V 110% (= 33 A) 150% (= 45 A) +12.0 V1 26.0 A 32 A max +12.0 V2 26.0 A 32 A max ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 168 Warning: Do not exceed a combined power output of 90 Watts for the +5 V and +3.3 V outputs. Exceeding a combined 90 Watts will overload the power subsystem and may cause the power supplies to overheat and malfunction. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 169: System Environmental Specifications

    Acoustic noise Sound Power: 7.0 BA in an idle state at typical office ambient temperature (23 +/- 2°C). Electrostatic +/-12 KV except I/O port +/- 8 KV per Intel Environment test specification. discharge (ESD) System Cooling 2550 BTU/Hr Requirement in BTU/Hr ®...
  • Page 170 ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 171: Appendix B: Intel Server Issue Report Form

    ® Appendix B: Intel Server Issue Report Form Issue Report Form (Rev 3.6) Note: Filling out this form completely is required for any escalation. =============================================================== Customer Contact Information: Customer Support Case #: =============================================================== ® Intel Server Board or System: (Example : S5000PSL or SR6850HW4)
  • Page 172 Thermal Solution Processor 1 Processor 2 Processor 3 Processor 4 Thermal solution (Heatsink) examples: (1U, Passive w/air ducting, Active w/fan, etc.) =============================================================== Memory: Manufacturer Part Number DRAM Part Number On Intel tested list? ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 173 Operating System Information (Example: RedHat* Enterprise Linux, Microsoft* Windows* Server 2003, Service pack 1, OEM CD): Manufacturer: Version: Language version (English, Arabic, Chinese (Simplified)): Service Pack Level or Kernel Revision: Distribution (OEM/Retail): =============================================================== ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 174 ® Intel RAID Controller: (Example SRCU42E) RAID controller part number (PBA number): RAID controller firmware version: Has the latest RAID firmware been tried? (Yes/No): RAID driver version: Has the latest RAID driver been tried? (Yes/No): RAID volumes configuration (disks & RAID level):...
  • Page 175 =============================================================== Issue impact statements: Do you have any potential Intel system, or component purchases that this issue is holding up? If yes, please provide a brief description below. Do you have systems already purchased that are not being delivered to your customers because of this issue? If yes, please provide a brief description below.
  • Page 176 ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 177: Appendix C: Led Decoder

    The two are concatenated as ACh Table 7. POST Progress Code LED Example Upper Nibble LEDs Lower Nibble LEDs LEDs LED #7 LED #6 LED #5 LED #4 LED #3 LED #2 LED #1 LED #0 Status Result ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 178: Figure 134. Diagnostic Led Placement Diagram

    SPD bad so no memory could be detected OxEAh Channel Training Error: DQ/DQS training failed on a channel during memory channel initialization. 0xEBh Memory Test Error: memory failed Hardware BIST. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 179 0x04h Early processor initialization where system BSP is selected 0x10h Power-on initialization of the host processor (bootstrap processor) 0x11h Host processor cache initialization (including AP) 0x12h Starting application processor initialization 0x13h SMM initialization ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 180 Reserved for PCI bus 0x54h Reserved for PCI bus 0x55h Reserved for PCI bus 0x56h Reserved for PCI bus 0x57h Reserved for PCI bus 0x58h Resetting USB bus 0x59h Reserved for USB devices ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 181 0x91h Disabling the keyboard 0x92h Detecting the presence of the keyboard 0x93h Enabling the keyboard 0x94h Clearing keyboard input buffer 0x95h Instructing keyboard controller to run Self Test (PS2 only) Mouse (USB only) ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 182 Trying to boot device selection 1 0xD2 Trying to boot device selection 2 0xD3 Trying to boot device selection 3 0xD4 Trying to boot device selection 4 0xD5 Trying to boot device selection 5 ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 183 Driver Execution Environment (DXE) Core (not accompanied by a beep code) 0xE4h Entered EFI driver execution (DXE) phase 0xE5h Started dispatching drivers 0xE6h Started connecting drivers DXE Drivers 0xE7h Waiting for user input ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 184 0x31h Crisis recovery has been initiated by software (corrupt flash) 0x34h Loading crisis recovery capsule 0x35h Handing off control to the crisis recovery capsule 0x3Fh Unable to complete crisis recovery capsule ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 185: Appendix D: Getting Help

    — A searchable knowledgebase to search for product information throughout the support site 2. If you are still unable to obtain a solution to your issue, send an email to Intel’s technical support center using the online form available at http://supportmail.intel.com/scripts-emf/welcome.aspx...
  • Page 186 ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 187: Appendix E: Regulatory And Certification Information

    (or higher) and operating at the same (or higher) speed as the microprocessor used on this server board. The final configuration of your end system product may require additional EMC compliance testing. For more information, please contact your local Intel representative.
  • Page 188: Product Emc Compliance - Class A Compliance

    GOST R 50628-95 Immunity (Russia) • Belarus Certification (Belarus) • Ukraine Certification (Ukraine) • KCC Certification (EMI) (Korea) • GB 9254 - CNCA Certification (China) • GB 17625 - (Harmonics) CNCA Certification (China) ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 189: Product Ecology Compliance

    Product Ecology Compliance Intel has a system in place to restrict the use of banned substances in accordance with world wide regulatory requirements. A Material Declaration Data Sheet is available for Intel products. For more reference on material restrictions and compliance you can view Intel's Environmental Product Content Specification at http://supplier.intel.com/ehs/environmental.htm.
  • Page 190: Product Regulatory Compliance Markings

    Product Regulatory Compliance Markings This Intel Server Chassis product if provided with the following regulatory and safety markings. In the event there is no room for a marking(s) on the chassis, the information is provided here in this guide. Table 9. Product Regulatory Compliance Markings...
  • Page 191 Number & Class A Warning GOST R Marking Russia KCC Mark (Korean Korea Communications Comission China Compulsory China Certification Mark Belarus Safety Belarus Compliance Mark Waste of Electronic Europe and Electrical Equipment Recycling Mark ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 192 This notice is required by California Code of Regulations, Title 22, Division 4.5, and Chapter 33: Best Management Practices for Perchlorate Materials. This product may include a battery which contains Perchlorate material. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 193 "WARNING:" Proper Ground "Apparaten skall anslutas till jordat uttag, när Outlet den ansluts till ett nätverk." "Laite on liitettävä suojamaadoituskoskettimilla varustettuun pistorasiaan." "Connect only to a properly earth grounded outlet." Safety Stand-by power ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 194: Rack Mount Installation Guidelines

    Location in accordance with articles 110-16, 110-17, and 110-18 of the National Electric Code, ANSI/NFPA 70. The DC source must be electrically isolated by double or reinforced insulation from any hazardous AC source. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 195: Power Cord Usage Guidelines

    Connector, server end: The connectors that plug into the AC receptacle on the server must be an approved IEC (International Electrotechnical Commission) 320, sheet C13, type female connector. • Cord length and flexibility: Cords must be less than 4.5 meters (14.76 feet) long. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 196: Electromagnetic Compatibility Notices

    (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. For questions related to the EMC performance of this product, contact: Intel Corporation 5200 N.E. Elam Young Parkway Hillsboro, OR 97124-6497 1-800-628-8686 This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
  • Page 197: Ices-003 (Canada)

    Install and use the equipment according to the instruction manual. BSMI (Taiwan) The BSMI Certification Marking and EMC warning is located on the outside rear area of the product. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 198: Kcc (Korea)

    Updated product information for configurations can be found on the Intel Server Builder Web site at the following URL: http://channel.intel.com/go/serverbuilder If you do not have access to Intel's Web address, please contact your local Intel representative. • Server Chassis: (base chassis is provided with power supply and fans) - UL listed.
  • Page 199: Appendix F: Installation/Assembly Safety Instructions

    5. Provide some electrostatic discharge (ESD) protection by wearing an antistatic wrist strap attached to chassis ground of the system-any unpainted metal surface-when handling components. 6. Do not operate the system with the chassis covers removed. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 200 • Provided with a properly grounded wall outlet. • Provided with sufficient space to access the power supply cord(s), because they serve as the product's main power disconnect. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 201: Deutsch

    Anschlußkabel von den I/O Anschlüssen oder Ports ab. 5. Tragen Sie ein geerdetes Antistatik Gelenkband, um elektrostatische Ladungen (ESD) über blanke Metallstellen bei der Handhabung der Komponenten zu vermeiden. 6. Schalten Sie das System niemals ohne ordnungsgemäß montiertes Gehäuse ein. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 202 Schutzhandschuhe tragen. Bei falschem Einsetzen einer neuen Batterie besteht Explosionsgefahr. Die Batterie darf nur durch denselben oder einen entsprechenden, vom Hersteller empfohlenen Batterietyp ersetzt werden. Entsorgen Sie verbrauchte Batterien den Anweisungen des Herstellers entsprechend. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 203: Français

    C'est le câble d'alimentation qui est considéré comme le moyen de se déconnecter du CA. La prise à laquelle le système est branché doit se situer à proximité de l'équipement et être facilement accessible. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 204 Le microprocesseur et le dissipateur de chaleur peuvent être chauds si le système a été sous tension. Faites également attention aux broches aiguës des cartes et aux bords tranchants du capot. Nous vous recommandons l'usage de gants de protection. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 205: Español

    No intente modificar ni usar el cable de alimentación de corriente alterna, si no corresponde exactamente con el tipo requerido. El número de cables suministrados se corresponden con el número de fuentes de alimentación de corriente alterna que tenga el producto ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 206 4. Inserte el bloqueo de seguridad en el sistema y bloquéelo para impedir que pueda accederse al mismo sin autorización. 5. Conecte todos los cables externos y los cables de alimentación CA al sistema. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 207: Italiano

    éstos hacen de medio principal de desconexión del sistema. Italiano Rivolgersi ad un tecnico specializzato per la riparazione dei componenti dell'alimentazione di questo prodotto. È possibile che il prodotto disponga di più fonti di alimentazione. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 208 4. Inserire e chiudere a chiave il lucchetto sul retro del sistema per impedire l'accesso non autorizzato al sistema. 5. Ricollegare tutti i cavi esterni e le prolunghe AC del sistema. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 209 • "Dotata di una presa a muro correttamente installata. • "Dotata di spazio sufficiente ad accedere ai cavi di alimentazione, i quali rappresentano il mezzo principale di scollegamento del sistema. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 210 ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 211: Appendix G: Safety Information

    To reduce the risk of bodily injury, electrical shock, fire, and equipment damage, read this document and observe all warnings and precautions in ® this guide before installing or maintaining your Intel server product. In the event of a conflict between the information in this document and information provided with the product or on the website for a particular product, the product documentation takes precedence.
  • Page 212: Intended Application Uses

    Conform to local occupational health and safety requirements when moving and lifting equipment. • Use mechanical assistance or other suitable assistance when moving and lifting equipment. • To reduce the weight for easier handling, remove any easily detachable components. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 213: Power And Electrical Warnings

    Do not attempt to modify or use an AC power cord if it is not the exact type required. A separate AC cord is required for each system power supply. ® Some power supplies in Intel servers use Neutral Pole Fusing. To avoid risk of shock use caution when working with power supplies that use Neutral Pole Fusing.
  • Page 214: System Access Warnings

    To avoid risk of potential electric shock, a proper safety ground must be implemented for the rack and each piece of equipment installed in it. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 215: Electrostatic Discharge (Esd)

    Caution: To avoid risk of radiation exposure and/or personal injury: • Do not open the enclosure of any laser peripheral or device • Laser peripherals or devices have are not user serviceable • Return to manufacturer for servicing ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 216: Deutsch

    Deutsch Sicherheitshinweise für den Server ® ® Das vorliegende Dokument bezieht sich auf Intel Serverplatinen, Intel Servergehäuse (Standfuß und Rack) sowie installierte Peripheriegeräte. Es enthält Warnungen und Vorsichtsmaßnahmen zur Vermeidung von Gefahren durch Verletzung, Stromschlag, Feuer und Beschädigungen von Geräten. Lesen Sie diese Dokument daher sorgfältig, ®...
  • Page 217: Zielbenutzer Der Anwendung

    Verwenden Sie mechanische oder andere geeignete Hilfsmittel zum Transportieren oder Anheben von Geräten. • Entfernen Sie alle Komponenten, die sich leicht abnehmen lassen, um das Gewicht zu reduzieren und die Handhabung zu erleichtern. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 218: Warnungen Zu Netzspannung Und Elektrizität

    Typ entspricht. Jedes Netzteil im System muß über ein eigenes Netzkabel angeschlossen werden. Einige Netzteile von Intel Servern verwenden Nullleitersicherungen. Vorsicht ist geboten im Umgang mit Netzteilen, welche Nullleitersicherungen verwenden, um das Risiko eines elektrischen Schlages zu vermeiden Das Netzteil in diesem Produkt enthält keine Teile, die vom Benutzer gewartet werden...
  • Page 219: Warnhinweise Für Den Systemzugang

    Gehen Sie bei der Installation von Geräten im Rack immer von unten nach oben vor, und bauen Sie das schwerste Gerät an der untersten Position im Rack ein. Ziehen Sie jeweils immer nur ein Gerät aus dem Rack heraus. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 220: Elektrostatische Entladungen (Esd)

    Inbetriebnahme des Systems ohne Abdeckung kann zur Beschädigung von Systemkomponenten führen. So bringen Sie die Abdeckung wieder an: • Vergewissern Sie sich zunächst, daß Sie keine Werkzeuge oder Teile im Gehäuse vergessen haben. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 221: Français

    ® d’installer ou de mettre à jour votre produit serveur Intel En cas de conflit entre les informations fournies dans ce document et celles livrées avec le produit ou publiées sur le site Web pour un produit particulier, la documentation du produit prime.
  • Page 222: Domaines D'utilisation Prévus

    Bien ventilé et à l’écart des sources de chaleur telles que la lumière directe du soleil et les radiateurs. • À l’écart des sources de vibration ou des chocs physiques. • Isolé des champs électromagnétiques importants produits par des appareils électriques. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 223: Pratiques De Manipulation De L'équipement

    Vous devez les débrancher avant d’ouvrir le châssis, d’ajouter ou de supprimer un composant non connectable à chaud. Les alimentations de certains serveurs Intel sont munies de doubles fusibles pôle/neutre: veuillez observer les précautions d'usage afin d'éviter tout risque d'eléctrocution.
  • Page 224: Avertissements Sur Le Cordon D'alimentation

    Éteignez le système en appuyant sur le bouton d’alimentation. • Déconnectez l’alimentation secteur en débranchant tous les cordons d’alimentation secteur du système ou de la prise murale. • Déconnectez l’ensemble des câbles et lignes de télécommunication qui sont connectés au système. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 225: Avertissements Sur Le Montage En Rack

    étiqueté comme contrôlant toute l’unité, et pas uniquement le ou les serveurs. Pour éviter tout risque d’électrocution, le rack et chaque élément de l’équipement installé dans le rack doivent être correctement reliés à la terre. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 226: Décharges Électrostatiques (Esd)

    Vérifiez tout d’abord que vous n’avez pas oublié d’outils ou de composants détachés à l’intérieur du système. • Vérifiez que les câbles, les cartes d’extension et les autres composants sont correctement installés. • Fixez les panneaux au châssis en suivant les instructions du produit. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 227: Périphériques Laser

    Español Información de seguridad del servidor Este documento se aplica a las tarjetas de servidor de Intel®, las carcasas de servidor de Intel® (montaje en bastidor y en pedestal) y los dispositivos periféricos. Para reducir el riesgo de daños corporales, descargas eléctricas, fuego y en el equipo, lea este documento y preste atención a todos las advertencias y precauciones de esta guía antes de instalar o...
  • Page 228: Aplicaciones Y Usos Previstos

    Provista de una toma de corriente alterna correctamente conectada a tierra. • Provista de espacio suficiente para acceder a los cables de la fuente de alimentación ya que constituyen la desconexión principal de la alimentación. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 229: Manipulacién Del Equipo

    CA estén desenchufado antes de abrir la carcasa, agregar o extraer cualquier componente que no es de conexión en funcionamiento. Algunas fuentes de alimentación de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje. Para evitar riesgos de choques electricos use precauciónes al trabajar con las fuentes de alimentación que utilizan el polo neutral de fuselaje.
  • Page 230: Advertencias El Acceso Al Sistema

    Devuélvala al fabricante para repararla. • Apague el servidor y desconecte todos los cables de alimentación antes de agregar o reemplazar cualquier componente que no es de conexión en funcionamiento. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 231: Advertencias Sobre El Montaje En Bastidor

    Precaución: Las descargas electrostáticas pueden dañar las unidades de disco, las tarjetas y otros componentes. Recomendamos que realice todos los procedimientos en una estación de trabajo protegida contra descargas electrostáticas. En caso de que no haya una ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 232: Otros Riesgos

    Compruebe primero que no ha dejado herramientas o piezas sueltas dentro del sistema. • Compruebe que los cables, tarjetas adicionales y otros componentes están instalados correctamente. • Sujete las cubiertas a la carcasa siguiendo las instrucciones del producto. ® Intel Server System SR2600UR/SR2625UR Service Guide...
  • Page 233 Precaución Para evitar el riesgo de la exposición a radiaciones o de daños personales: • No abra la caja de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser reparados por el usuario • Haga que el fabricante los repare ® Intel Server System SR2600UR/SR2625UR Service Guide...