Intel SR2520SAXSR - Server System - 0 MB RAM User Manual

User guide
Table of Contents

Advertisement

Quick Links

®
Intel
Server System SR2520SA
User's Guide
A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/
Products
Intel Order Number D69842-002

Advertisement

Table of Contents
loading

Summary of Contents for Intel SR2520SAXSR - Server System - 0 MB RAM

  • Page 1 ® Intel Server System SR2520SA User’s Guide A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/ Products Intel Order Number D69842-002...
  • Page 2 Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur.
  • Page 3 ® Intel Server System SR2520SA User’s Guide...
  • Page 4 § ® Intel Server System SR2520SA User’s Guide...
  • Page 5: Preface

    BIOS Setup screens, how to perform a BIOS update, and how to reset the password or ® CMOS. Information about the specific BIOS settings and screens is available in the Intel 5000 Series Chipsets Server Board Family Datasheet. See “Server System References”...
  • Page 6 Rack handles, in the server system product box • Rails, in the server system product box • Intel Software CD combo kit, in the server system product box • 3rd party software CD, in the server system product box ®...
  • Page 7 Rack handles, in the server system product box • Rails, in the server system product box • Intel Software CD combo kit, in the server system product box • 3rd party software CD, in the server system product box ®...
  • Page 8 Rack handles, in the server system product box • Rails, in the server system product box • Intel Software CD combo kit, in the server system product box • 3rd party software CD, in the server system product box ®...
  • Page 9: Safety Information

    Safety Information Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the ® Intel Server Deployment Toolkit 2.0 CD and/or at http://support.intel.com/support/...
  • Page 10 重要安全指导 在执行任何指令之前,请阅读本文档中的所有注意事项及安全声明。 和/或 http://support.intel.com/support/motherboards/server/sb/CS-010770.htm 上的 Intel Server Boards and Server Chassis Safety Information(《Intel 服务器主板与服务器机箱安全信息》)。 ® Intel Server System SR2520SA User’s Guide...
  • Page 11 Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board. ® Intel Server System SR2520SA User’s Guide...
  • Page 12 ® Intel Server System SR2520SA User’s Guide...
  • Page 13: Table Of Contents

    Table of Contents Preface ......................... v About this Manual ........................v Manual Organization ......................v Product Contents ........................v ® Intel Server System SR2520SAX Contents ............... vi ® Intel Server System SR2520SAXS Contents ............vii ® Intel Server System SR2520SAF Contents ...............viii Safety Information .....................
  • Page 14 Removing the Rack Handles ..................63 Chapter 4: Server Utilities ..................65 Using the BIOS Setup Utility ....................65 Starting Setup ......................65 If You Cannot Access Setup ..................65 Setup Menus ....................... 65 Upgrading the BIOS ......................67 ® Intel Server System SR2520SA User’s Guide...
  • Page 15 Restriction of Hazardous Substances (RoHS) Compliance ..........92 End-of-Life / Product Recycling ...................92 Appendix E: Warranty ....................93 Limited Warranty for Intel® Chassis Subassembly Products ..........93 Appendix F: Troubleshooting ................. 97 Resetting the System ......................97 Problems following Initial System Installation ..............98 First Steps Checklist ....................98...
  • Page 16 Deutsch ..........................124 Sicherheitshinweise für den Server ................124 Sicherheitshinweise und Vorsichtsmaßnahmen ............124 Zielbenutzer der Anwendung ..................125 Standortauswahl ....................... 125 Handhabung von Geräten ..................125 Warnungen zu Netzspannung und Elektrizität ............126 ® Intel Server System SR2520SA User’s Guide...
  • Page 17 Advertencias de alimentacién y eléctricas ..............137 Advertencias sobre el cable de alimentación ............137 Advertencias el acceso al sistema ................138 Advertencias sobre el montaje en bastidor ...............139 Descarga electrostática (ESD) ..................139 Otros riesgos ......................140 ® Intel Server System SR2520SA User’s Guide xvii...
  • Page 18 ® xviii Intel Server System SR2520SA User’s Guide...
  • Page 19: List Of Figures

    List of Figures ® Figure 1. Intel Server System SR2520SA ................3 Figure 2. ChassisComponents (SR2520SAX/SR2520SAXS and SR2520SAXR/ SR2520SAXSR)........................7 Figure 3. ChassisComponents (SR2520SAF/SR2520SAFR) ........... 8 Figure 4. Server Board Connector and Component Locations ..........9 Figure 5. BIOS Select Jumper....................10 Figure 6.
  • Page 20 Figure 55. Removing the Rack Handle ................... 64 Figure 56. Clear Password Jumper ..................68 Figure 57. Clear CMOS Jumper ..................... 69 Figure 58. Cable Routing (SR2520SAX/SR2520SAXS and SR2520SAXR/SR2520SAXSR) 71 Figure 59. Cable Routing (SR2520SAF/SR2520SAFR) ............72 ® Intel Server System SR2520SA User’s Guide...
  • Page 21 List of Tables Table 1. Server System References ..................1 ® Table 2. Intel Server System SR2520SA Feature Summary ..........4 Table 3. NIC LED Descriptions ....................14 Table 4. Setup Menu Key Use ....................66 Table 5. Power Supply Output Capability ................73 Table 6.
  • Page 22 ® xxii Intel Server System SR2520SA User’s Guide...
  • Page 23: Chapter 1: Server System References

    A link to the SMaRT Tool is available under "Other Resources" at and interactive repair the right side of the screen at information http://support.intel.com/support/motherboards/server/s5000vsa/ Accessories or other Intel Spares and Configuration Guide server products Found: available from your Intel field representative or on the Server Configurator Tool at http://indigo.intel.com/ serverconfiguratortool/default.aspx...
  • Page 24 To make sure your system Power Budget Tool falls within the allowed Found at: power budget http://support.intel.com/support/motherboards/server/s5000vsa/ ® For software to manage Intel System Management Software ® your Intel server Found at: http://support.intel.com/support/motherboards/server/sysmgmt/ index.htm For diagnostics test Diagnostics software Found at: http://support.intel.com/support/motherboards/server/s5000vsa/ ®...
  • Page 25: Chapter 2: Server System Features

    This chapter briefly describes the main features of the server system. This chapter provides illustrations of the product, a list of the server system features, and diagrams showing the location of important components and connections on the server system. AF001439 ® Figure 1. Intel Server System SR2520SA...
  • Page 26: Table 2. Intel ® Server System Sr2520Sa Feature Summary

    Up to two 45nm 2P Dual-Core Intel Xeon processors. Product codes SR2520SAFR, SR2520SAXR, and SR2520SAXSR only. ® ® Up to two 45nm next generation Quad-Core Intel Xeon processors. Product codes SR2520SAFR, SR2520SAXR, and SR2520SAXSR only. • Memory SR2520SAX/SR2520SAXS and SR2520SAXR/...
  • Page 27 One full length 64-bit/133MHz PCI-X* connector • One 64-bit/100MHz PCI-X* connector • Two x4 PCI Express* connectors ® NOTE: Only low-profile PCI cards are supported in the Intel Server System SR2520SA • Peripherals Slimline bay for IDE optical drive •...
  • Page 28 ® Table 2. Intel Server System SR2520SA Feature Summary Feature Description • Power Supply Single 600 W power supply module (SR2520SAF) • Redundant 600 W power supply modules (SR2520SAX/ SR2520SAXS and SR2520SAXR/SR2520SAXSR) • Fans Three system cooling fans • Two non-redundant fans in power supply ®...
  • Page 29: Chassis Component Identification

    Control Panel (standard control panel shown) CPU Air Duct Optical Drive Bay Server Board Slimline Floppy Drive Hot-Swap Power Supplies Hard Drive Bays (drives not included) Hot-Swap Power Cage Figure 2. ChassisComponents (SR2520SAX/SR2520SAXS and SR2520SAXR/SR2520SAXSR) ® Intel Server System SR2520SA User’s Guide...
  • Page 30: Figure 3. Chassiscomponents (Sr2520Saf/Sr2520Safr)

    Control Panel (standard control panel shown) CPU Air Duct Optical Drive Bay Server Board Slimline Floppy Drive Fixed Power Supply Hard Drive Bays (drives not included) Power Distribution Board Figure 3. ChassisComponents (SR2520SAF/SR2520SAFR) ® Intel Server System SR2520SA User’s Guide...
  • Page 31: Figure 4. Server Board Connector And Component Locations

    FF. SATA SGPIO GG. USB 4-5 HH. SATA 0 Connector SATA 1 Connector JJ. SATA 2/SAS 0 Connector KK. SATA 3/SAS 1 Connector LL. SATA 4/SAS 2 Connector MM. SATA 5/SAS 3 Connector ® Intel Server System SR2520SA User’s Guide...
  • Page 32: Configuration Jumpers

    If pins 1-2 are jumpered, the BIOS in the lower bank will be selected on the next reset. These pins should be jumpered on 2-3 for normal operation. Figure 5. BIOS Select Jumper CMOS PASSWORD Default Default CLEAR CLEAR CMOS PASSWORD J1J1 J1J2 AF000187 ® Intel Server System SR2520SA User’s Guide...
  • Page 33: Figure 6. Recovery Jumpers

    These pins should be jumpered on 1-2 for normal operation. BMC Force Update Mode If pins 2-3 are jumpered, BMC Force Update Mode is enabled. These pins should be jumpered on 1-2 for normal operation. Figure 6. Recovery Jumpers ® Intel Server System SR2520SA User’s Guide...
  • Page 34: Figure 7. Light Guided Diagnostic Leds

    ® Intel Light Guided Diagnostics (SR2520SAX/ SR2520SAXS and SR2520SAXR/SR2520SAXSR Only) The server board contains diagnostic LEDs to help you identify failed and failing components, and to help you identify the server from among several servers. Except for the ID LED, the status LED, and the 5V standby LED, the LEDs turn on (amber) only if a failure occurs.
  • Page 35: Figure 8. Intel ® Server System Sr2520Saf/Sr2520Safr Back Panel Connectors

    USB Ports Mouse/Keyboard Video Serial Port A Diagnostic LEDs NIC1 and NIC2 (10/100/1000 Mb) ® Figure 8. Intel Server System SR2520SAF/SR2520SAFR Back Panel Connectors AF001441 Power Supply 1 Receptacle NIC1 and NIC2 (10/100/1000 Mb) Power Supply 1 Module PCI Expansion Slots...
  • Page 36: Hot-Swap Backplane

    Figure 10. Hot-Swap Backplane ® Note: The Intel Server System SR2520SAX/SR2520SAXR ships with a passive backplane with 6 ® SATA cables installed. The Intel Server System SR2520SAXS/SR2520SAXSR ships with an active backplane with 2 SAS cables installed. ® Intel Server System SR2520SA User’s Guide...
  • Page 37: Sata

    RAID Activation Key AXXRAKSW5 accessory to enable RAID 5, see the documentation that is included with the accessory kit. ® Notes: For assistance in navigating through the F2 BIOS Setup utility, see the Intel Server Board S5000VSA Technical Product Specification.
  • Page 38 SATA ports will be available. ® • When the SAS option ROM is enabled in the BIOS Setup utility, Intel Embedded Server RAID Technology II is available. This enables SAS RAID modes 0, 1, or 10 for the four blue ports on the server board. The SAS controller can mix SAS and SATA drives.
  • Page 39: Control Panel

    USB 2.0 Port Allows you to attach a USB component to the front of the chassis. Power/Sleep Button Powers on/off the system. Puts the system in an ACPI sleep state. Figure 11. Standard Control Panel ® Intel Server System SR2520SA User’s Guide...
  • Page 40: Bezels

    Figure 12. Optional Peripherals (SR2520SAX/SR2520SAXS and SR2520SAXR/SR2520SAXSR) The drives must be purchased separately. The following figure shows the available options. AF001662 Slimline floppy drive Optical drive bay (Optional; drive not included) Figure 13. Optional Peripherals (SR2520SAF/SR2520SAFR) ® Intel Server System SR2520SA User’s Guide...
  • Page 41: Hard Disk Drives

    Server System SR2520SA can be mounted into a rack. Intel provides three options to mount this server into a rack. When installing the chassis into a rack, Intel recommends you install systems from the bottom of the rack to the top. In other words, install the first system in the rack into the bottom position of the rack, the second system in the second position from the bottom, and so on.
  • Page 42 ® Intel Server System SR2520SA User’s Guide...
  • Page 43: Chapter 3: Hardware Installations And Upgrades

    ® ® Two Intel rack options are available to install the Intel Server System SR2520SA in a rack. The options are the fixed bracket kit and the basic rail kit. Note: Follow all safety guidelines while removing a system from a rack to avoid injury.
  • Page 44: Fixed Bracket Rack Mount Installation

    20. Attach the rear end of the outer rail to the rear bracket with at least one screw. If possible, attach at two places. 21. In the same manner, attach the other rail assembly to the other side. ® Intel Server System SR2520SA User’s Guide...
  • Page 45: Basic Rail Rack Mount Removal

    (attached to the rack). 9. Engage the matching rails and slide the server chassis into the rack until the two safety stops lock into position. 10. Depress the two safety locks (one on each side). ® Intel Server System SR2520SA User’s Guide...
  • Page 46: Removing And Installing The Front Bezel

    Removing and Installing the Front Bezel ® The front bezel is available as optional accessories for the Intel Server System SR2520SA. Note the orientation in the figure below - the control panel is at the right. If you are installing a bezel on your server system, make sure you position it as shown.
  • Page 47: Removing The Front Bezel

    Removing the Front Bezel Use the steps below if your system includes a front bezel. 1. Unlock the bezel. 2. Pull the bezel from the server system. AF001444 Figure 15. Removing the Front Bezel ® Intel Server System SR2520SA User’s Guide...
  • Page 48: Installing The Front Bezel

    Use the steps below if your system includes either the standard front bezel or the front ® bezel for the Intel Local Control Panel. The front bezel is optional. 1. At each end of the bezel, line up the center notch on the bezel with the center guide on the rack handles.
  • Page 49: Installing The System Cover

    2. Slide the cover forward until it clicks into place (see letter “A”). 3. Insert the screws at the three locations in the top cover (see letter “B”). 4. Reconnect all peripheral devices and the AC power cord(s). ® Intel Server System SR2520SA User’s Guide...
  • Page 50: Removing And Installing The Processor Air Duct

    2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the server system cover. For instructions, see “Removing the System Cover”. 4. Lift the processor air duct from its location over the two processor sockets. ® Intel Server System SR2520SA User’s Guide...
  • Page 51: Figure 19. Removing The Processor Air Duct

    AF001447 Figure 19. Removing the Processor Air Duct ® Intel Server System SR2520SA User’s Guide...
  • Page 52: Installing The Processor Air Duct

    Figure 20. Installing the Processor Air Duct 5. Install the server system cover. For instructions, see “Installing the System Cover”. 6. Plug all peripheral devices and the AC power cable(s) into the server. ® Intel Server System SR2520SA User’s Guide...
  • Page 53: Installing And Removing Memory

    See "Memory" for a discussion of the memory requirements and options. See “Server System References” for a link to the list of tested DIMMs. ® Note: The Intel Server System SR2520SAF/SR2520SAFR only has four DIMM sockets. Installing DIMMs To install DIMMs, follow these steps: 1.
  • Page 54: Figure 21. Installing The Memory

    10. When the DIMM is inserted, push down on the top edge of the DIMM until the retaining clips snap into place (see letter “C” in the figure above). Make sure the clips are firmly in place (see letter “D” in the figure above). ® Intel Server System SR2520SA User’s Guide...
  • Page 55: Removing Dimms

    1. Observe the safety and ESD precautions in “Safety Information”. 2. Turn off all peripheral devices connected to the server. Turn off the server. 3. Disconnect the AC power cord(s) from the server. ® Intel Server System SR2520SA User’s Guide...
  • Page 56: Figure 22. Lifting The Processor Socket Handle

    9. Line up the alignment marks on the processor and the socket, and insert the processor into the socket. Note: Make sure the alignment triangle mark and the alignment triangle cutout align correctly. ® Intel Server System SR2520SA User’s Guide...
  • Page 57: Installing The Heat Sink(S)

    2. Loosely screw in the captive screws on the heat sink corners in a diagonal manner. Do no fully tighten one screw before tightening another. 3. Gradually and equally tighten each captive screw until each is firmly tightened. ® Intel Server System SR2520SA User’s Guide...
  • Page 58: Removing A Processor

    7. Lift the heat sink from the processor. If it does not pull up easily, twist the heat sink again. Do not force the heat sink from the processor. Doing so could damage the processor. 8. Lift the processor lever. ® Intel Server System SR2520SA User’s Guide...
  • Page 59: Installing And Removing A Hot-Swap Hard Drive (Sr2520Sax/Sr2520Saxs And Sr2520Saxr/Sr2520Saxsr)

    1. Remove the front bezel if it is installed. For instructions, see “Removing the Front Bezel”. 2. Open the green latch at the front of the hard drive carrier. 3. Pull out on the black lever and slide the carrier from the server system. ® Intel Server System SR2520SA User’s Guide...
  • Page 60: Figure 26. Removing Hot-Swap Disk Carrier From The Server System

    Figure 26. Removing Hot-swap Disk Carrier from the Server System (SR2520SAX/SR2520SAXS and SR2520SAXR/SR2520SAXSR) ® Intel Server System SR2520SA User’s Guide...
  • Page 61: Figure 27. Removing Retention Device From Drive Carrier (Sr2520Sax/Sr2520Saxs And Sr2520Saxr/Sr2520Saxsr)

    10. When the black drive carrier lever begins to close by itself, push on it to lock the drive assembly into place (see letter “B” in the figure below). ® Intel Server System SR2520SA User’s Guide...
  • Page 62: Figure 28. Install Drive Assemby Into The Server System (Sr2520Sax/Sr2520Saxs And Sr2520Saxr/Sr2520Saxsr)

    11. Install the server system cover. For instructions, see “Installing the System Cover”. 12. (Optional) Install the front bezel. For instructions, see “Installing the Front Bezel”. 13. Plug all peripheral devices and the AC power cable(s) into the server. ® Intel Server System SR2520SA User’s Guide...
  • Page 63: Removing A Sas Or Sata Hot-Swap Hard Disk Drive (Sr2520Sax/Sr2520Saxs And Sr2520Saxr/Sr2520Saxsr)

    Note: The server system does not support all hard drives. See “Server System References“ an Internet link to a list of supported hardware. Installing a Fixed Hard Disk Drive (SR2520SAF/ SR2520SAFR) 1. Remove the server system cover. ® Intel Server System SR2520SA User’s Guide...
  • Page 64: Figure 29. Installing Fixed Hard Drive(S) Into The Server System (Sr2520Saf/Sr2520Safr)

    Figure 29. Installing Fixed Hard Drive(s) into the Server System (SR2520SAF/SR2520SAFR) 6. Install the server system cover. For instructions, see “Installing the System Cover”. 7. Plug all peripheral devices and the AC power cable(s) into the server. ® Intel Server System SR2520SA User’s Guide...
  • Page 65: Removing A Fixed Hard Disk Drive (Sr2520Saf/Sr2520Safr)

    5. Using the four screws you removed in step 2, secure the hard drive cage into the server system. 6. Install the server system cover. For instructions, see “Installing the System Cover”. 7. Plug all peripheral devices and the AC power cable(s) into the server. ® Intel Server System SR2520SA User’s Guide...
  • Page 66: Installing Or Removing The Optical Drive

    6. Remove the four screws holding the drive bracket to the server system (see letter “A” in the figure below), and remove the bracket from the system (see letter “B” in the figure below). AF001825 Figure 31. Removing Drive Bracket from the Server System ® Intel Server System SR2520SA User’s Guide...
  • Page 67: Figure 32. Installng Optical Drive Into The Drive Bracket

    9. Lower the drive bracket into the system and slide it forward into place (see letter “A” in the figure below). 10. Secure the drive bracket into place with four screws (see letter “B” in the figure below). ® Intel Server System SR2520SA User’s Guide...
  • Page 68: Removing The Optical Drive

    6. Remove the four screws holding the drive bracket to the server system (see letter “A” in the figure below), and remove the bracket from the system (see letter “B” in the figure below). ® Intel Server System SR2520SA User’s Guide...
  • Page 69: Figure 35. Removing Drive Bracket And Optical Drive From The Server System

    9. Install the server system cover. For instructions, see “Installing the System Cover”. 10. (Optional) Install the front bezel. For instructions, see “Installing the Front Bezel”. 11. Plug all peripheral devices and the AC power cable(s) into the server. ® Intel Server System SR2520SA User’s Guide...
  • Page 70: Installing And Removing A Pci Add-In Card

    7. Insert add-in card until it seats in the slot connector (see letter “C”). 8. Secure add-in card with screw as shown (see letter “D”). AF001453 Figure 37. Installing an Add-In Card Note: Make sure that all empty add-in card slots have filler panels installed. ® Intel Server System SR2520SA User’s Guide...
  • Page 71: Removing A Pci Add-In Card

    7. Install the processor air duct. For instructions, see “Installing the Processor Air Duct”. 8. Install the server system cover. For instructions, see “Installing the System Cover”. 9. Plug all peripheral devices and the AC power cable(s) into the server. ® Intel Server System SR2520SA User’s Guide...
  • Page 72: Installing And Removing The Server Board

    5. Place the server board into the server system as shown in the figure below (see letter “A”). 6. Attach the server board with eight screws (see letter “B”). AF001469 Figure 39. Installing the Server Board ® Intel Server System SR2520SA User’s Guide...
  • Page 73: Removing The Server Board

    “Removing the Processor Air Duct”. 5. Remove the eight screws from the server board (see letter “A”) and lift the server board from the server system (see letter “B”). AF001468 Figure 40. Removing the Server Board ® Intel Server System SR2520SA User’s Guide...
  • Page 74: Replacing The Backup Battery

    Varning: Explosionsfara vid felaktigt batteribyte. Använd samma batterityp eller en ekvivalent typ som rekommenderas av apparattillverkaren. Kassera använt batteri enligt fabrikantens instruktion. Varoitus: Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan laitevalmistajan suosittelemaan tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden mukaisesti. ® Intel Server System SR2520SA User’s Guide...
  • Page 75: Figure 41. Replacing The Backup Battery

    8. Remove the new lithium battery from its package, and, being careful to observe the correct polarity, insert it in the battery socket. 9. Close the chassis. 10. Run Setup to restore the configuration settings to the RTC. ® Intel Server System SR2520SA User’s Guide...
  • Page 76: Replacing The Redundant Power Supply (Sr2520Sax/Sr2520Saxs And Sr2520Saxr/ Sr2520Saxsr)

    (see letter “B”) as shown in the figure below. AF001455 Figure 42. Removing Power Supply Module from the Server System (SR2520SAX/SR2520SAXS and SR2520SAXR/SR2520SAXSR) ® Intel Server System SR2520SA User’s Guide...
  • Page 77: Replacing The Fixed Power Supply (Sr2520Saf/Sr2520Safr)

    5. Lift up slightly to disengage the power supply from the chassis tab (see letter “C” in the figure below). 6. Slide the power supply forward to disengage the back panel and lift it straight up to remove (see letter “D” in the figure below). ® Intel Server System SR2520SA User’s Guide...
  • Page 78: Figure 44. Removing Power Supply Module From The Server System

    8. Make sure the power supply is seated behind the chassis tab (see letter “B” in the figure below). 9. Install the power supply bracket using the two screws you removed in step 4 (see letter “C” in the figure below). ® Intel Server System SR2520SA User’s Guide...
  • Page 79: Replacing The Front Panel Board

    “Safety Information”. 2. Power down the server and unplug all peripheral devices and the AC power cable(s). 3. Remove the front bezel if it is installed. For instructions, see “Removing the Front Bezel”. ® Intel Server System SR2520SA User’s Guide...
  • Page 80: Figure 46. Removing The Front Panel Board

    7. Remove the light pipes from the front panel board you just removed (see letters “A” and “B” in the figure below). These will be used in the replacement front panel board. AF001660 Figure 47. Removing the Light Pipes from the Front Panel Board ® Intel Server System SR2520SA User’s Guide...
  • Page 81: Figure 48. Installing Front Panel Board Into The Server System

    11. Install the server system cover. For instructions, see “Installing the System Cover”. 12. (Optional) Install the front bezel. For instructions, see “Installing the Front Bezel”. 13. Plug all peripheral devices and the AC power cable(s) into the server. ® Intel Server System SR2520SA User’s Guide...
  • Page 82: Replacing A System Fan

    ® The system fans at the front of the Intel Server System SR2520SA can be individually replaced if one of them fails. Use the steps below to replace either a dual rotor fan or a single rotor fan.
  • Page 83: Figure 51. Removing A Fan From The Fan Module

    9. Lower the fan module into the server system (see letter “A” in the figure below) and secure the module with four screws as shown (see letter “B”). 10. Connect the fan cables to the server board (see letter “C” in the figure below). ® Intel Server System SR2520SA User’s Guide...
  • Page 84: Installing And Removing The Rack Handles

    3. Align the rack handle with the two holes on the side of the server system as shown in the figure below. 4. Attach the rack handle to the server system with two screws as shown in the figure below. ® Intel Server System SR2520SA User’s Guide...
  • Page 85: Removing The Rack Handles

    3. Remove the front bezel if it is installed. For instructions, see “Removing the Front Bezel”. 4. Remove the two screws holding the rack handle in place, and remove the rack handle from the server system as shown in the figure below. ® Intel Server System SR2520SA User’s Guide...
  • Page 86: Figure 55. Removing The Rack Handle

    AF001459 Figure 55. Removing the Rack Handle 5. Plug all peripheral devices and the AC power cable(s) into the server. ® Intel Server System SR2520SA User’s Guide...
  • Page 87: Chapter 4: Server Utilities

    You can run BIOS Setup with or without an operating system ® being present. See “Server System References” for a link to the Intel 5000 Series Chipsets Server Board Family Datasheet where you will find details about specific BIOS setup screens.
  • Page 88: Table 4. Setup Menu Key Use

    If "No" is selected and the <Enter> key is pressed, or if the <Esc> key is pressed, the user is returned to where they were before <F9> was pressed without affecting any existing field values. ® Intel Server System SR2520SA User’s Guide...
  • Page 89: Upgrading The Bios

    Press <F2> Key if you want to run SETUP 2. Write down the current settings in the BIOS Setup program. Note: Do not skip step 2. You will need these settings to configure your server at the end of the procedure. ® Intel Server System SR2520SA User’s Guide...
  • Page 90: Upgrading The Bios

    3. Move the jumper from the normal operation position, Password Clear Protect, at pins 1 and 2 to the Password Clear Erase position, covering pins 2 and 3. CMOS PASSWORD Default Default CLEAR CLEAR CMOS PASSWORD J1J1 J1J2 AF000187 Figure 56. Clear Password Jumper ® Intel Server System SR2520SA User’s Guide...
  • Page 91: Clearing The Cmos

    1 and 2. 6. Close the server chassis. 7. Reconnect the AC power and power up the system. 8. The CMOS is now cleared and can be reset by going into the BIOS setup. ® Intel Server System SR2520SA User’s Guide...
  • Page 92 ® Intel Server System SR2520SA User’s Guide...
  • Page 93: Appendix A: Technical Reference

    Appendix A: Technical Reference Cable Routing (SR2520SAX/SR2520SAXS and SR2520SAXR/SR2520SAXSR) When you add or remove components from your server system, make sure your cables are routed correctly before reinstalling the server system cover. Use caution to make sure no cables or wires are pinched and that the airflow from the fans is not blocked. Use the figures below to determine the correct cable routing.
  • Page 94: Cable Routing (Sr2520Saf/Sr2520Safr)

    HDD 3 to Server Board SAS 1/SATA 3 HDD 4 to Server Board SAS 2/SATA 4 HDD 5 to Server Board SAS 3/SATA 5 USB Floppy Hard Drive Power AF001664 Figure 59. Cable Routing (SR2520SAF/SR2520SAFR) ® Intel Server System SR2520SA User’s Guide...
  • Page 95: 600W Single Power Supply Input Voltages

    Warning: Do not exceed a combined power output of 90 Watts for the +5 V and +3.3 V outputs. Exceeding a combined 90 Watts will overload the power subsystem and may cause the power supplies to overheat and malfunction. ® Intel Server System SR2520SA User’s Guide...
  • Page 96: System Environmental Specifications

    7 Bels in sound power for a typical office ambient temperature (65-75 °F). Your selection of peripherals may change the noise level. Electrostatic Tested to 15 kilovolts (kV); no component damage. discharge (ESD) ® Intel Server System SR2520SA User’s Guide...
  • Page 97: Appendix B: Led Decoder (Sr2520Sax /Sr2520Saxs And Sr2520Saxr/ Sr2520Saxsr Only)

    Appendix B: LED Decoder (SR2520SAX /SR2520SAXS and SR2520SAXR/ SR2520SAXSR Only) During the system boot process, BIOS executes a number of platform configuration processes, each of which is assigned a specific hex POST code number. As each configuration routine is started, BIOS will display the given POST code to the POST Code Diagnostic LEDs found on the back edge of the server board.
  • Page 98: Table 8. Diagnostic Led Post Code Decoder

    Detecting presence of memory 0x24h Programming timing parameters in the memory controller 0x25h Configuring memory parameters in the memory controller 0x26h Optimizing memory controller settings 0x27h Initializing memory, such as ECC init 0x28h Testing memory ® Intel Server System SR2520SA User’s Guide...
  • Page 99 Resetting the console controller 0x79h Disabling the console controller 0x7Ah Enabling the console controller Keyboard (PS2 or USB) 0x90h Resetting the keyboard 0x91h Disabling the keyboard 0x92h Detecting the presence of the keyboard ® Intel Server System SR2520SA User’s Guide...
  • Page 100 Trying boot device selection 0xD4 Trying boot device selection 0xD5 Trying boot device selection 0xD6 Trying boot device selection 0xD7 Trying boot device selection 0xD8 Trying boot device selection 0xD9 Trying boot device selection ® Intel Server System SR2520SA User’s Guide...
  • Page 101 Exiting Sleep state 0xF8h Operating system has requested EFI to close boot services (ExitBootServices ( ) has been called) 0xF9h Operating system has switched to virtual address mode (SetVirtualAddressMap ( ) has been called) ® Intel Server System SR2520SA User’s Guide...
  • Page 102 Crisis recovery has been initiated because of a user request 0x31h Crisis recovery has been initiated by software (corrupt flash) 0x34h Loading crisis recovery capsule 0x35h Handing off control to the crisis recovery capsule 0x3Fh Unable to complete crisis recovery. ® Intel Server System SR2520SA User’s Guide...
  • Page 103: Appendix C: Getting Help

    (Intel reserves the right to change the pricing for telephone support at any time without notice). Before calling, fill out an Intel Server Issue Report Form. A form is provided on the Internet. For the fastest service, please submit your form via the Internet.
  • Page 104: Latin America

    Easter Island....Contact AT&T USA at 800 800 311. Once connected, dial 800 843 4481 Mainland and Juan .. Contact AT&T USA at 800 225 288. Once connected, dial 800 843 4481 ® Intel Server System SR2520SA User’s Guide...
  • Page 105 Panama..Contact AT&T USA at 00 800 001 0109. Once connected, dial 800 843 4481 Paraguay ... 001 916 377 0114 Peru ... 001 916 377 0114 Uruguay..001 916 377 0114 Venezuela... Contact AT&T USA at 0 800 2255 288. Once connected, dial 800 843 4481 ® Intel Server System SR2520SA User’s Guide...
  • Page 106 ® Intel Server System SR2520SA User’s Guide...
  • Page 107: Appendix D: Regulatory And Compliance Information

    (or higher) and operating at the same (or higher) speed as the microprocessor used on this server board. The final configuration of your end system product may require additional EMC compliance testing. For more information, please contact your local Intel representative.
  • Page 108: Product Emc Compliance - Class A Compliance

    This server system has been tested and verified to comply with the following electromagnetic compatibility (EMC) regulations when installed in a compatible Intel® host system. For information on compatible host system(s) refer to Intel's Server Builder Web site or contact your local Intel representative.
  • Page 109: Certifications / Registrations / Declarations

    IRAM Certification (Argentina) • CNCA Certification (China) • Ecology Declaration (International) Product Regulatory Compliance Markings ® This Intel server system product is provided with the following regulatory marks. Table 9. Product Regulatory Compliance Markings Regulatory Compliance Region Marking cULus Listing Marks...
  • Page 110 Marking C-Tick Mark Australia / New Zealand VCCI Marking (Class A) Japan BSMI Certification Taiwan Number & Class A Warning GOST R Marking Russia RRL MIC Mark Korea China Compulsory China Certification Mark ® Intel Server System SR2520SA User’s Guide...
  • Page 111: Electromagnetic Compatibility Notices

    (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. For questions related to the EMC performance of this product, contact: Intel Corporation 5200 N.E. Elam Young Parkway Hillsboro, OR 97124-6497 1-800-628-8686 This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
  • Page 112: Industry Canada (Ices-003)

    Install and use the equipment according to the instruction manual. BSMI (Taiwan) The BSMI Certification Marking and EMC warning is located on the outside rear area of the product. ® Intel Server System SR2520SA User’s Guide...
  • Page 113: Korean Compliance (Rrl)

    Updated product information for configurations can be found on the Intel Server Builder Web site at the following URL: http://channel.intel.com/go/serverbuilder If you do not have access to Intel's Web address, please contact your local Intel representative. •...
  • Page 114: Restriction Of Hazardous Substances (Rohs) Compliance

    Restriction of Hazardous Substances (RoHS) Compliance Intel has a system in place to restrict the use of banned substances in accordance with the European Directive 2002/95/EC. Compliance is based on declaration that materials banned in the RoHS Directive are either (1) below all applicable substance threshold limits or (2) an approved/pending RoHS exemption applies.
  • Page 115: Appendix E: Warranty

    "as is" unless specifically provided for otherwise in any software license accompanying the software. If any Product furnished by Intel which is the subject of this Limited Warranty fails during the warranty period for reasons covered by this Limited Warranty, Intel, at its option, will: •...
  • Page 116: Warranty Limitations And Exclusions

    Limitations of Liability Intel's responsibility under this, or any other warranty, implied or expressed, is limited to repair, replacement, or refund, as set forth above. These remedies are the sole and exclusive remedies for any breach of warranty.
  • Page 117: Telephone Support

    Telephone Support If you cannot find the information you need on Intel's World Wide Web site (http:// www.intel.com/), call your local distributor or an Intel Customer Support representative.
  • Page 118 ® Intel Server System SR2520SA User’s Guide...
  • Page 119: Appendix F: Troubleshooting

    In addition to the server firmware and files, also update any drivers used for components you have installed in your system, such as video drivers, network drivers, and SATA drivers. Intel provides a package called the "Platform Confidence Test" that may help with your diagnostics. See “Server System References”...
  • Page 120: Problems Following Initial System Installation

    • Are all integrated components from the tested components lists? Check the tested memory, and chassis lists, as well as the supported hardware and operating system list. See “Server System References” for links to the tested component lists. ® Intel Server System SR2520SA User’s Guide...
  • Page 121: Hardware Diagnostic Testing

    If the operating system prompt does not appear, “No Characters Appear on Screen”. Specific Problems and Corrective Actions This section provides possible solutions for these specific problems: • Power light does not light. • No characters appear on screen. ® Intel Server System SR2520SA User’s Guide...
  • Page 122: Power Light Does Not Light

    No Characters Appear on Screen Check the following: • Is the keyboard functioning? Test it by turning the "Num Lock" function on and off to make sure the Num Lock light is functioning. ® Intel Server System SR2520SA User’s Guide...
  • Page 123: Characters Are Distorted Or Incorrect

    • Does this video monitor work correctly if plugged into a different system? System Cooling Fans Do Not Rotate Properly If the system cooling fans are not operating properly, it is an indication of possible system component failure. ® Intel Server System SR2520SA User’s Guide...
  • Page 124: Drive Activity Light Does Not Light

    • Is the drive properly configured? Cannot Connect to a Server • Make sure the network cable is securely attached to the correct connector at the system back panel. • Try a different network cable. ® Intel Server System SR2520SA User’s Guide...
  • Page 125: Problems With Network

    The add-in adapter stopped working without apparent cause • Reseat the adater. • Put the adapter in a different slot. • The network driver files may be corrupt or deleted. Delete and then reinstall the drivers. • Run diagnostics. ® Intel Server System SR2520SA User’s Guide...
  • Page 126: System Boots When Installing Pci Card

    • If you suspect that a transient voltage spike, power outage, or brownout might have occurred, reload the software and try running it again. Symptoms of voltage spikes ® Intel Server System SR2520SA User’s Guide...
  • Page 127: Devices Are Not Recognized Under Device Manager (Microsoft* Windows* Operating System)

    (Microsoft* Windows* Operating System) The Microsoft* Windows* operating systems do not include all of the drivers for the ® Intel chipsets, onboard NICs, and other components. See “Server System References” for a link to the current drivers and chipset files.
  • Page 128: Led Information

    LED Information ® The Intel Server Board S5000PAL includes LEDs that can aid in troubleshooting your system. A table of these LEDs with a description of their use is listed below. Table 11. LED Information LED Name Function Location LED Color...
  • Page 129: Appendix G: Installation/Assembly Safety Instructions

    5. Provide some electrostatic discharge (ESD) protection by wearing an antistatic wrist strap attached to chassis ground of the system-any unpainted metal surface-when handling components. 6. Do not operate the system with the chassis covers removed. ® Intel Server System SR2520SA User’s Guide...
  • Page 130 • Provided with a properly grounded wall outlet. • Provided with sufficient space to access the power supply cord(s), because they serve as the product's main power disconnect. ® Intel Server System SR2520SA User’s Guide...
  • Page 131: Deutsch

    Anschlußkabel von den I/O Anschlüssen oder Ports ab. 5. Tragen Sie ein geerdetes Antistatik Gelenkband, um elektrostatische Ladungen (ESD) über blanke Metallstellen bei der Handhabung der Komponenten zu vermeiden. 6. Schalten Sie das System niemals ohne ordnungsgemäß montiertes Gehäuse ein. ® Intel Server System SR2520SA User’s Guide...
  • Page 132 Schutzhandschuhe tragen. Bei falschem Einsetzen einer neuen Batterie besteht Explosionsgefahr. Die Batterie darf nur durch denselben oder einen entsprechenden, vom Hersteller empfohlenen Batterietyp ersetzt werden. Entsorgen Sie verbrauchte Batterien den Anweisungen des Herstellers entsprechend. ® Intel Server System SR2520SA User’s Guide...
  • Page 133: Français

    Notez que le commutateur CC de mise sous tension /hors tension du panneau avant n'éteint pas l'alimentation CA du système. Pour mettre le système hors tension, vous devez débrancher chaque câble d'alimentation de sa prise. ® Intel Server System SR2520SA User’s Guide...
  • Page 134 Le microprocesseur et le dissipateur de chaleur peuvent être chauds si le système a été sous tension. Faites également attention aux broches aiguës des cartes et aux bords tranchants du capot. Nous vous recommandons l'usage de gants de protection. ® Intel Server System SR2520SA User’s Guide...
  • Page 135: Español

    No intente modificar ni usar el cable de alimentación de corriente alterna, si no corresponde exactamente con el tipo requerido. El número de cables suministrados se corresponden con el número de fuentes de alimentación de corriente alterna que tenga el producto ® Intel Server System SR2520SA User’s Guide...
  • Page 136 4. Inserte el bloqueo de seguridad en el sistema y bloquéelo para impedir que pueda accederse al mismo sin autorización. 5. Conecte todos los cables externos y los cables de alimentación CA al sistema. ® Intel Server System SR2520SA User’s Guide...
  • Page 137: Italiano

    éstos hacen de medio principal de desconexión del sistema. Italiano Rivolgersi ad un tecnico specializzato per la riparazione dei componenti dell'alimentazione di questo prodotto. È possibile che il prodotto disponga di più fonti di alimentazione. ® Intel Server System SR2520SA User’s Guide...
  • Page 138 4. Inserire e chiudere a chiave il lucchetto sul retro del sistema per impedire l'accesso non autorizzato al sistema. 5. Ricollegare tutti i cavi esterni e le prolunghe AC del sistema. ® Intel Server System SR2520SA User’s Guide...
  • Page 139 • "Dotata di una presa a muro correttamente installata. • "Dotata di spazio sufficiente ad accedere ai cavi di alimentazione, i quali rappresentano il mezzo principale di scollegamento del sistema. ® Intel Server System SR2520SA User’s Guide...
  • Page 140 ® Intel Server System SR2520SA User’s Guide...
  • Page 141: Appendix H: Safety Information

    To reduce the risk of bodily injury, electrical shock, fire, and equipment damage, read this document and observe all warnings and precautions in ® this guide before installing or maintaining your Intel server product. In the event of a conflict between the information in this document and information provided with the product or on the website for a particular product, the product documentation takes precedence.
  • Page 142: Intended Application Uses

    Conform to local occupational health and safety requirements when moving and lifting equipment. • Use mechanical assistance or other suitable assistance when moving and lifting equipment. • To reduce the weight for easier handling, remove any easily detachable components. ® Intel Server System SR2520SA User’s Guide...
  • Page 143: Power And Electrical Warnings

    Do not attempt to modify or use an AC power cord if it is not the exact type required. A separate AC cord is required for each system power supply. ® Some power supplies in Intel servers use Neutral Pole Fusing. To avoid risk of shock use caution when working with power supplies that use Neutral Pole Fusing.
  • Page 144: System Access Warnings

    To avoid risk of potential electric shock, a proper safety ground must be implemented for the rack and each piece of equipment installed in it. ® Intel Server System SR2520SA User’s Guide...
  • Page 145: Electrostatic Discharge (Esd)

    Caution: To avoid risk of radiation exposure and/or personal injury: • Do not open the enclosure of any laser peripheral or device • Laser peripherals or devices have are not user serviceable • Return to manufacturer for servicing ® Intel Server System SR2520SA User’s Guide...
  • Page 146: Deutsch

    Deutsch Sicherheitshinweise für den Server ® ® Das vorliegende Dokument bezieht sich auf Intel Serverplatinen, Intel Servergehäuse (Standfuß und Rack) sowie installierte Peripheriegeräte. Es enthält Warnungen und Vorsichtsmaßnahmen zur Vermeidung von Gefahren durch Verletzung, Stromschlag, Feuer und Beschädigungen von Geräten. Lesen Sie diese Dokument daher sorgfältig, ®...
  • Page 147: Zielbenutzer Der Anwendung

    Verwenden Sie mechanische oder andere geeignete Hilfsmittel zum Transportieren oder Anheben von Geräten. • Entfernen Sie alle Komponenten, die sich leicht abnehmen lassen, um das Gewicht zu reduzieren und die Handhabung zu erleichtern. ® Intel Server System SR2520SA User’s Guide...
  • Page 148: Warnungen Zu Netzspannung Und Elektrizität

    Typ entspricht. Jedes Netzteil im System muß über ein eigenes Netzkabel angeschlossen werden. Einige Netzteile von Intel Servern verwenden Nullleitersicherungen. Vorsicht ist geboten im Umgang mit Netzteilen, welche Nullleitersicherungen verwenden, um das Risiko eines elektrischen Schlages zu vermeiden Das Netzteil in diesem Produkt enthält keine Teile, die vom Benutzer gewartet werden...
  • Page 149: Warnhinweise Für Den Systemzugang

    Gehen Sie bei der Installation von Geräten im Rack immer von unten nach oben vor, und bauen Sie das schwerste Gerät an der untersten Position im Rack ein. Ziehen Sie jeweils immer nur ein Gerät aus dem Rack heraus. ® Intel Server System SR2520SA User’s Guide...
  • Page 150: Elektrostatische Entladungen (Esd)

    Inbetriebnahme des Systems ohne Abdeckung kann zur Beschädigung von Systemkomponenten führen. So bringen Sie die Abdeckung wieder an: • Vergewissern Sie sich zunächst, daß Sie keine Werkzeuge oder Teile im Gehäuse vergessen haben. ® Intel Server System SR2520SA User’s Guide...
  • Page 151: Français

    ® d’installer ou de mettre à jour votre produit serveur Intel En cas de conflit entre les informations fournies dans ce document et celles livrées avec le produit ou publiées sur le site Web pour un produit particulier, la documentation du produit prime.
  • Page 152: Domaines D'utilisation Prévus

    Bien ventilé et à l’écart des sources de chaleur telles que la lumière directe du soleil et les radiateurs. • À l’écart des sources de vibration ou des chocs physiques. • Isolé des champs électromagnétiques importants produits par des appareils électriques. ® Intel Server System SR2520SA User’s Guide...
  • Page 153: Pratiques De Manipulation De L'équipement

    Vous devez les débrancher avant d’ouvrir le châssis, d’ajouter ou de supprimer un composant non connectable à chaud. Les alimentations de certains serveurs Intel sont munies de doubles fusibles pôle/neutre: veuillez observer les précautions d'usage afin d'éviter tout risque d'eléctrocution.
  • Page 154: Avertissements Sur Le Cordon D'alimentation

    Éteignez le système en appuyant sur le bouton d’alimentation. • Déconnectez l’alimentation secteur en débranchant tous les cordons d’alimentation secteur du système ou de la prise murale. • Déconnectez l’ensemble des câbles et lignes de télécommunication qui sont connectés au système. ® Intel Server System SR2520SA User’s Guide...
  • Page 155: Avertissements Sur Le Montage En Rack

    étiqueté comme contrôlant toute l’unité, et pas uniquement le ou les serveurs. Pour éviter tout risque d’électrocution, le rack et chaque élément de l’équipement installé dans le rack doivent être correctement reliés à la terre. ® Intel Server System SR2520SA User’s Guide...
  • Page 156: Décharges Électrostatiques (Esd)

    Vérifiez tout d’abord que vous n’avez pas oublié d’outils ou de composants détachés à l’intérieur du système. • Vérifiez que les câbles, les cartes d’extension et les autres composants sont correctement installés. • Fixez les panneaux au châssis en suivant les instructions du produit. ® Intel Server System SR2520SA User’s Guide...
  • Page 157: Périphériques Laser

    Español Información de seguridad del servidor Este documento se aplica a las tarjetas de servidor de Intel®, las carcasas de servidor de Intel® (montaje en bastidor y en pedestal) y los dispositivos periféricos. Para reducir el riesgo de daños corporales, descargas eléctricas, fuego y en el equipo, lea este documento y preste atención a todos las advertencias y precauciones de esta guía antes de instalar o...
  • Page 158: Aplicaciones Y Usos Previstos

    Provista de una toma de corriente alterna correctamente conectada a tierra. • Provista de espacio suficiente para acceder a los cables de la fuente de alimentación ya que constituyen la desconexión principal de la alimentación. ® Intel Server System SR2520SA User’s Guide...
  • Page 159: Manipulacién Del Equipo

    CA estén desenchufado antes de abrir la carcasa, agregar o extraer cualquier componente que no es de conexión en funcionamiento. Algunas fuentes de alimentación de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje. Para evitar riesgos de choques electricos use precauciónes al trabajar con las fuentes de alimentación que utilizan el polo neutral de fuselaje.
  • Page 160: Advertencias El Acceso Al Sistema

    Devuélvala al fabricante para repararla. • Apague el servidor y desconecte todos los cables de alimentación antes de agregar o reemplazar cualquier componente que no es de conexión en funcionamiento. ® Intel Server System SR2520SA User’s Guide...
  • Page 161: Advertencias Sobre El Montaje En Bastidor

    Precaución: Las descargas electrostáticas pueden dañar las unidades de disco, las tarjetas y otros componentes. Recomendamos que realice todos los procedimientos en una estación de trabajo protegida contra descargas electrostáticas. En caso de que no haya una ® Intel Server System SR2520SA User’s Guide...
  • Page 162: Otros Riesgos

    Compruebe primero que no ha dejado herramientas o piezas sueltas dentro del sistema. • Compruebe que los cables, tarjetas adicionales y otros componentes están instalados correctamente. • Sujete las cubiertas a la carcasa siguiendo las instrucciones del producto. ® Intel Server System SR2520SA User’s Guide...
  • Page 163 Precaución Para evitar el riesgo de la exposición a radiaciones o de daños personales: • No abra la caja de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser reparados por el usuario • Haga que el fabricante los repare ® Intel Server System SR2520SA User’s Guide...
  • Page 164 ® Intel Server System SR2520SA User’s Guide...

Table of Contents