Intel SR1530AH - Server System - 0 MB RAM User Manual

Intel SR1530AH - Server System - 0 MB RAM User Manual

User guide
Hide thumbs Also See for SR1530AH - Server System - 0 MB RAM:
Table of Contents

Advertisement

®
Intel
Server System SR1530AH /
SR1530AHLX / SR1530HAHLX
User's Guide
A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/
Products
Intel Order Number D59196-002

Advertisement

Table of Contents
loading

Summary of Contents for Intel SR1530AH - Server System - 0 MB RAM

  • Page 1 ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX User’s Guide A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/ Products Intel Order Number D59196-002...
  • Page 2 Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur.
  • Page 3: Safety Information

    Safety Information Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the ® Intel Server Deployment Toolkit 2.0 CD and/or at http://support.intel.com/support/...
  • Page 4 重要安全指导 在执行任何指令之前,请阅读本文档中的所有注意事项及安全声明。 和/或 上的 Intel http://support.intel.com/support/motherboards/server/sb/CS-010770.htm Server Boards and Server Chassis Safety Information(《Intel 服务器主板与服务器机箱安全信息》)。 ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX User’s Guide...
  • Page 5: Warnings

    Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX User’s Guide...
  • Page 6 ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX User’s Guide...
  • Page 7: Preface

    BIOS Setup screens, how to perform a BIOS update, and how to reset the password or ® CMOS. Information about the specific BIOS settings and screens is available in the Intel Server Board S3000AH Technical Product Specification. See Table 1 on page x for a link to the Technical Product Specification.
  • Page 8: Product Contents

    ® Intel Server Systems SR1530AHLX / SR1530HAHLX ship with the Intel Server Board S3000AHLX. ® There are three versions of this server system: the Intel Server System SR1530AHLX, ® ® the Intel Server System SR1530AH, and the Intel Server System SR1530HAHLX. The contents of each server system are listed below.
  • Page 9: Intel ® Server System Sr1530Hahlx Contents

    • Documentation, drivers, and installation CD ® Intel Server System SR1530HAHLX Contents ® Your Intel Server System SR1530HAHLX ships with the following items: ® • One Intel Server Board S3000AHLX, installed in the server system • One 350-watt power supply module, installed in the server system •...
  • Page 10: Server System References

    Accessories or other Intel Spares and Configuration Guide server products Found: available from your Intel field representative or on the Server Configurator Tool at http://indigo.intel.com/ serverconfiguratortool/default.aspx Hardware (peripheral Tested Hardware Operating Systems List boards, adapter cards) Found at: http://support.intel.com/support/motherboards/server/...
  • Page 11: Table Of Contents

    Warnings ..........................v Preface ........................vii About this Manual ........................ vii Manual Organization ......................vii Product Contents .........................viii ® Intel Server System SR1530AH / SR1530AHLX Contents ........viii ® Intel Server System SR1530HAHLX Contents ............ix Server System References ....................x Chapter 1: Server System Features ................
  • Page 12 Installing and Removing a PCI Add-in Card ................ 64 Installing a PCI Add-in Card ..................64 Removing a PCI Add-in Card ..................65 Replacing the Server Board ....................67 Removing the Server Board ..................67 Installing the Server Board ..................69 ® Intel Server System SR1530AH / SR1530AHLX...
  • Page 13 Problems with Newly Installed Application Software ..........108 Problems with Application Software that Ran Correctly Earlier .........108 Devices are not Recognized under Device Manager (Microsoft* Windows* Operating System) ......................109 Hard Drive(s) are not Recognized ................109 ® Intel Server System SR1530AH / SR1530AHLX xiii...
  • Page 14 Alimentation et avertissements en matiére d’électricité ..........135 Avertissements sur le cordon d’alimentation ............. 136 Avertissements sur l’accés au systéme ..............136 Avertissements sur le montage en rack ..............137 Décharges électrostatiques (ESD) ................138 ® Intel Server System SR1530AH / SR1530AHLX...
  • Page 15 Regulated Specified Components ................153 Restriction of Hazardous Substances (RoHS) Compliance ..........154 End-of-Life / Product Recycling ..................154 Appendix F: Warranty .................... 155 Limited Warranty for Intel® Chassis Subassembly Products ..........155 Appendix G: Getting Help ..................159 World Wide Web ........................159 Telephone ..........................159 ®...
  • Page 16 ® Intel Server System SR1530AH / SR1530AHLX...
  • Page 17 List of Tables Table 1. Server System References ..................x ® Table 2. Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX Feature Summary Table 3. NIC LED Descriptions ....................7 Table 4. Setup Menu Key Use ....................20 Table 5. Power Supply Output Capability ................99 Table 6.
  • Page 18 ® xviii Intel Server System SR1530AH / SR1530AHLX...
  • Page 19: List Of Figures

    List of Figures ® Figure 1. Intel Server System SR1530AH/SR1530AHLX ............1 ® Figure 2. Intel Server System SR1530HAHLX................ 1 Figure 3. Front Controls and LEDs (SR1530AH / SR1530AHLX)..........5 Figure 4. Front Controls and LEDs (SR1530HAHLX) ............... 6 Figure 5. Back Panel Connectors....................7 Figure 6.
  • Page 20 Figure 83. Removing the PCI Cooling Fan (SR1530AH/SR1530AHLX) ........ 90 Figure 84. Removing Fan from the Server System (SR1530HAHLX) ........91 Figure 85. Installing Fan into the Server System (SR1530HAHLX)........92 Figure 86. Installing the Rack Handle ..................93 ® Intel Server System SR1530AH / SR1530AHLX...
  • Page 21 Figure 87. Removing the Rack Handle ................... 94 Figure 88. Power Cable Routing (SR1530AH / SR1530AHLX) ..........96 Figure 89. Data Cable Routing (SR1530AH / SR1530AHLX) ..........97 Figure 90. Cable Routing (SR1530HAHLX) ................98 ® Intel Server System SR1530AH / SR1530AHLX...
  • Page 22 ® xxii Intel Server System SR1530AH / SR1530AHLX...
  • Page 23: Chapter 1: Server System Features

    ® Figure 1. Intel Server System SR1530AH/SR1530AHLX Note: The figure above is shown with an optional optical drive installed.
  • Page 24 One of the following: • ® ® Intel Server System SR1530AH: Intel Server Board S3000AH • ® ® Intel Server Systems SR1530AHLX / SR1530HAHLX: Intel Server Board S3000AHLX Processor Support for one: ® ® • Dual-Core Intel Xeon processor 3000 sequence • ®...
  • Page 25 On-board ATI* ES1000 video controller with 16 MB DDR SDRAM ® Intel 10/100/1000 82541PI Gigabit Ethernet Controller In addition, one of the following: ® ® • Intel Server System SR1530AH: Intel 10/100/1000 82573V Gigabit Ethernet Controller • ® ® Intel Server System SR1530AHLX: Intel 10/100/1000...
  • Page 26: Table 2. Intel ® Server System Sr1530Ah / Sr1530Ahlx / Sr1530Hahlx Feature Summary

    ® Table 2. Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX Feature Summary Feature Description • One front panel USB port • One internal USB header providing two USB ports ® System Management Intel System Management Software ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 27: Chassis Component Identification

    The front of the server system includes the following buttons and LEDs. AF001000 USB Port Hard Disk Drive Activity LED Power Button NIC1 LED Not used NIC2 LED System Power LED Figure 3. Front Controls and LEDs (SR1530AH / SR1530AHLX) ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 28: System Front Panel (Sr1530Hahlx)

    The front of the server system includes the following buttons and LEDs. AF001573 NIC1 LED HDD Activity LED NIC2 LED USB Port Power LED Power Button Figure 4. Front Controls and LEDs (SR1530HAHLX) ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 29: System Rear

    Solid Amber Network connection in place Blinking Amber Transmit/receive activity Right 10 Mbps connection (if left LED is on or blinking) Solid Amber 100 Mbps connection Solid Green 1000 Mbps connection ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 30: Peripheral Devices (Sr1530Ah / Sr1530Ahlx)

    AF001074 Slimline Optical Drive Bay Hard Disk Drive Bay HDD0 (located under the slimline optical drive bay) Hard Disk Drive Bay HDD1 Figure 6. Optional Peripherals (SR1530AH / SR1530AHLX) ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 31: Peripheral Devices (Sr1530Hahlx)

    Figure 7. Optional Peripherals (SR1530HAHLX) Hard Disk Drives ® ® The Intel Server System SR1530AH, the Intel Server System SR1530AHLX, and the ® Intel Server System SR1530HAHLX each provide four SATA ports and one IDE connection. The four SATA ports are near the front left side of the server board. An IDE device can be connected to the standard IDE connector located near the SATA ports.
  • Page 32: Slimline Optical Drive Carrier

    To use the slimline CD-ROM drive provided by Intel, use order code AXXSCD. To use the slimline DVD drive provided by Intel, use order code AXXDVDROM. To use the slimline DVD CDR drive provided by Intel, use order code AXXDVDCDR.
  • Page 33: Internal Components (Sr1530Ah / Sr1530Ahlx)

    System Blower Fans (two) Processor Air Duct Front Panel Board PCI Add-in Card Bracket Control Panel Processor and Heat Sink Slimline Optical Drive Bay Power Supply Figure 8. System Components (SR1530AH / SR1530AHLX) ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 34: Internal Components (Sr1530Hahlx)

    Processor and Heat Sink PCI Air Baffle Power Supply System Blower Fans (two) Front Panel Board Processor Air Duct Control Panel Server Board Hard Drive Carriers (three) Figure 9. System Components (SR1530HAHLX) ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 35: Server Board Connectors / Components

    PCI 32/33 Slot 2 Processor Fan DD. SATA Port 2 ® ATI* ES1000 Video Controller DIMM Sockets (2B and 2A) EE. Intel 82801 ICH7R PCI Express* x4 Slot 3 DIMM Sockets (1B and 1A) FF. Front Panel Connector ® Intel...
  • Page 36: Figure 11. S3000Ah Connector And Component Locations

    DIMM Sockets (2B and 2A) CC. SATA Port 2 ® ATI* ES1000 Video Controller DIMM Sockets (1B and 1A) DD. Intel 82801 ICH7R PCI Express* x4 Slot 3 System Front DIMM Blower Header EE. Front Panel Connector PCI Express x8 Slot 5 System Front Processor Blower Header FF.
  • Page 37: Configuration Jumpers

    NIC1 NVM Protect Mode If pins 2-3 are jumpered, the Intel 82573E/V firmware will be ® programmed. When pins 1-2 are jumpered, the Intel 82573E/V firmware is protected and will not be updated. These pins should be jumpered on 1-2 for normal operation.
  • Page 38: Raid Support

    Embedded Server RAID Technology II feature provides RAID modes 0, 1, and 10. ® Notes: For assistance in navigating through the F2 BIOS Setup utility, see the Intel Server Board S3000AH Technical Product Specification. For information on setting up RAID, see the RAID Software Guide that is included on the ®...
  • Page 39: Memory

    Memory ® The Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX provides four DIMM sockets across two banks, bank 1 and bank 2. Bank 1 consists of DIMM sockets 1A and 1B. Bank 2 consists of DIMM sockets 2A and 2B.
  • Page 40 ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 41: Chapter 2: Server Utilities

    See the links under “Server System References” on page x for a link to the ® Intel Server Board S3000AH Technical Product Specification where you will find details about specific BIOS setup screens. Starting Setup You can enter and start BIOS Setup under several conditions: •...
  • Page 42: Table 4. Setup Menu Key Use

    If “No” is selected and the <Enter> key is pressed, or if the <Esc> key is pressed, the user is returned to where they were before <F9> was pressed without affecting any existing field values. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 43: Upgrading The Bios

    2. Write down the current settings in the BIOS Setup program. Note: Do not skip step 2. You will need these settings to configure your server at the end of the procedure. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 44: Upgrading The Bios

    Note: You may encounter a CMOS Checksum error or other problem after reboot. If this happens, shut down the system and boot it again. CMOS checksum errors require that you enter Setup, check your settings, save your settings, and exit Setup. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 45: Clearing The Cmos

    6. Return the CMOS Clear jumper to the CMOS Clear by BMC location, covering pins 1 and 2. 7. Close the server chassis. 8. Reconnect the AC power and power up the system. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 46 ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 47: Chapter 3: Hardware Installations And Upgrades

    Server System SR1530HAHLX are hot swappable and will be noted as such in the instructions that follow where applicable. ® Note: Most of the illustrations in this chapter show the Intel Server System SR1530AH / SR1530AHLX with an optional optical drive installed. The instructions for removing and ®...
  • Page 48: Removing And Installing The Front Bezel

    Removing and Installing the Front Bezel ® The front bezel is available as an optional accessories for the Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX. Note the orientation in the figures below and make sure you position your bezel as shown.
  • Page 49: Installing The Front Bezel

    2. Push the bezel onto the front of the server system until it clicks into place. 3. Lock the bezel. AF001058 Figure 15. Installing the Front Bezel ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 50: Removing And Installing The Server Cover

    6. SR1530AH/SR1530AHLX: Push rearward on the blue grip point at the front of the server. Slide the cover back until it stops and then lift the cover upward to remove it. See letter “C”. AF000662 Figure 16. Removing the Server System Cover (SR1530AH/SR1530AHLX) ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 51: Figure 17. Removing The Server System Cover (Sr1530Hahlx)

    8. SR1530HAHLX: Push rearward on the blue grip point at the front of the server. Slide the cover back until it stops and then lift the cover upward to remove it. See letter “B”. AF001578 Figure 17. Removing the Server System Cover (SR1530HAHLX) ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 52: Installing The Server System Cover

    Slide the cover forward. See letter “A” in the figure below. 6. SR1530HAHLX: Install the four screws at the front of the server. See letter “B”. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 53: Removing And Installing The Processor Air Duct

    3. Remove the server system cover. For instructions, see “Removing the Server System Cover”. 4. Lift the processor air duct from its location behind the two system blower fans (see Figure 20 for SR1530AH/SR1530AHLX; see for SR1530HAHLX). ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 54: Figure 20. Removing The Processor Air Duct (Sr1530Ah/Sr1530Ahlx)

    AF000664 Figure 20. Removing the Processor Air Duct (SR1530AH/SR1530AHLX) AF001580 Figure 21. Removing the Processor Air Duct (SR1530HAHLX) ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 55: Installing The Processor Air Duct

    Use caution not to pinch or disengage cables that may be near or under the air duct. 5. Install the server system cover. For instructions, see “Installing the Server System Cover”. AF000665 Figure 22. Installing the Processor Air Duct (SR1530AH/SR1530AHLX) ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 56: Installing And Removing Memory

    2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the server system cover. For instructions, see “Removing the Server System Cover” on page ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 57: Figure 24. Installing The Memory

    10. Make sure the clips are firmly in place. See letter “D” in the figure. 11. Install the server system cover. For instructions, see “Installing the Server System Cover”. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 58: Removing Dimms

    6. Holding the DIMM by the edges, lift it from the socket, and store it in an anti-static package. 7. Install the server system cover. For instructions, see “Installing the Server System Cover”. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 59: Replacing The Processor

    9. Remove the processor. 10. If installing a replacement processor, see “Installing the Processor” on page Otherwise, install the protective socket cover over the empty processor socket and then reinstall the chassis cover. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 60: Installing The Processor

    Raise the CPU load plate (see Figure 26). AF000529 Figure 26. Opening the Load Plate Caution: Do not touch the socket pins; they are very sensitive and easily damaged. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 61: Figure 27. Removing The Shipping Cover

    9. Remove the protective socket cover. See Figure AF000530 Figure 29. Removing the Protective Socket Cover Note: Retain the protective socket cover for use when removing a processor that will not be replaced. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 62: Installing The Heat Sink

    Do no fully tighten one screw before tightening another. 5. Gradually and equally tighten each captive screw in the same order until each is firmly tightened. AF001049 Figure 30. Installing the Heat Sink ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 63: Installing And Removing A Hard Drive (Sr1530Ah / Sr1530Ahlx)

    2. Power down the server. Unplug all peripheral devices and the AC power cable. 3. Remove the server system cover. For instructions, see “Removing the Server System Cover” on page 4. Locate the drive position you want to use. See Figure ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 64: Figure 31. Locating Drive Positions (Sr1530Ah/Sr1530Ahlx)

    Save this screw. You will use it to reinstall the drive assembly later. 7. Lift the drive carrier from the chassis. See letter “B” in the figure. AF001050 Figure 32. Removing Drive Carrier from the Server System (SR1530AH/ SR1530AHLX) ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 65: Figure 33. Installing Drive Into Drive Carrier (Sr1530Ah/Sr1530Ahlx)

    Note: The assembly that contains the optical drive bracket must be installed at the left side of the system. AF000667 Figure 34. Install Drive Assembly into the Server System (SR1530AH/ SR1530AHLX) ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 66: Figure 35. Connecting Hard Drive Power And Data Cables (Sr1530Ah/Sr1530Ahlx)

    HDD0 power connector. See letter “D” in Figure AF001173 Figure 35. Connecting Hard Drive Power and Data Cables (SR1530AH/ SR1530AHLX) 16. Install the server system cover. For instructions, see “Installing the Server System Cover”. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 67: Removing A Hard Disk Drive (Sr1530Ah/Sr1530Ahlx)

    “Installing a Hard Disk Drive (SR1530AH/SR1530AHLX)” on page 41, beginning with step 8. 10. Insert the screws that held the drive in the carrier into the screw locations on the carrier for future use. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 68: Figure 37. Install Drive Carrier Into The Server System (Sr1530Ah/Sr1530Ahlx)

    Note: The assembly that contains the optical drive bracket must be installed at the left side of the system. AF000667 Figure 37. Install Drive Carrier into the Server System (SR1530AH/ SR1530AHLX) 13. Install the server system cover. For instructions, see “Installing the Server System Cover”. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 69: Installing And Removing A Hot-Swap Sata Drive (Sr1530Hahlx)

    1. Remove the front bezel if it is installed. For instructions, see “Removing the Front Bezel”. 2. Locate the drive position you want to use. See Figure AF001582 Figure 38. Locating Drive Positions (SR1530HAHLX) ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 70: Figure 39. Removing The Drive Carrier (Sr1530Hahlx)

    9. Align the holes in the drive to the holes in the drive carrier and attach it to the carrier with the screws that were attached to the plastic retention device. See letter “B” in Figure AF001584 Figure 40. Installing Drive into Drive Carrier (SR1530HAHLX) ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 71: Removing A Hot-Swap Sata Drive (Sr1530Hahlx)

    7. With the black lever in the fully open position, slide the drive carrier into the server system. The green latch must be to the right. Do not push on the black lever until the lever begins to close by itself. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 72: Installing Or Removing A Slimline Optical Drive (Sr1530Ah / Sr1530Ahlx)

    5. Note the orientation of the PCI cooling fan that is located behind the optical drive bay, then lift the fan from the mounting pegs. It is not necessary to disconnect the fan cable. See letter “A” in Figure ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 73: Figure 42. Lifting Pci Cooling Fan From Mounting Pegs (Sr1530Ah/Sr1530Ahlx)

    Figure 43. Removing the Knock-out from the Sheet Metal Panel 7. Attach the interposer board to the rear of the CD-ROM or DVD-ROM drive, using two screws, as shown by the following figure. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 74: Figure 44. Attaching The Interposer Board

    11. A daisy chain cable is used for the hard disk drives and the optical drive. Connect the end connector on the daisy chain cable to the power connector on the optical drive. See letter “C” in the figure below. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 75: Figure 46. Installing The Optical Drive Into The System

    “Installing the Front Bezel” on page 15. Install the server system cover. For instructions, see “Installing the Server System Cover”. 16. Plug all peripheral devices and the AC power cable into the server. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 76: Removing A Slimline Optical Drive

    “C” in the figure below. Save this screw. You will reinstall it later. 8. Slide the optical drive out through the front of the system. See letter “D” in the figure. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 77: Figure 49. Removing The Optical Drive From The Server System

    See letter “A” in the figure below. 11. Carefully pull the interposer board from the drive, detaching the interposer board connector from the drive. See letter “B” in the figure below. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 78: Figure 51. Removing The Interposer Board From The Optical Drive

    Figure 52. Installing the PCI Cooling Fan (SR1530AH/SR1530AHLX) 15. Optional: Install the front bezel. For instructions, see “Installing the Front Bezel” on page 16. Install the server system cover. For instructions, see “Installing the Server System Cover”. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 79: Installing Or Removing A Slimline Optical Drive (Sr1530Hahlx)

    AF001643 Figure 53. Attaching the Optical Drive to the Attachment Bracket 7. Slide the optical drive assembly in through the front of the chassis (see letter “A” in the figure below). ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 80: Removing A Slimline Optical Drive (Sr1530Hahlx)

    5. Remove the screws holding the drive in place (see letters “A” and “B” in the figure below) and slide the optical drive assembly out through the front of the chassis (see letter “C” in the figure below). ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 81: Figure 55. Removing The Optical Drive From The System

    Figure 56. Removing the Optical Drive from the Attachment Bracket 8. Optional: Install the front bezel. For instructions, see “Installing the Front Bezel” on page 9. Install the server system cover. For instructions, see “Installing the Server System Cover”. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 82: Installing And Removing The Pci Riser Assembly

    Figure 57. Removing PCI Riser Assembly from the Server System 6. If you need to add or replace a PCI riser connector, see “Installing or Replacing a PCI Riser Card” on page ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 83: Installing The Pci Riser Assembly

    4. Connect any cables to add-in cards that require them. See your add-in card documentation for information and add-in card requirements. 5. Install the server system cover. For instructions, see “Installing the Server System Cover”. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 84: Installing Or Replacing A Pci Riser Card

    7. Remove the two screws that attach the riser card to the riser assembly. See the following figure. Save these screws to be used later. AF001061 Figure 59. Removing Riser Card from Riser Assembly ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 85: Installing A Pci Riser Card

    9. Install the PCI riser assembly into the server system. For instructions, see “Installing the PCI Riser Assembly” on page 10. Connect any cables to add-in cards that require them. See your add-in card documentation for information and add-in card requirements. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 86: Installing And Removing A Pci Add-In Card

    3. Remove the server system cover. For instructions, see “Removing the Server System Cover” on page 4. Remove the PCI riser assembly. For instructions, see “Removing the PCI Riser Assembly” on page ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 87: Removing A Pci Add-In Card

    3. Remove the server system cover. For instructions, see “Removing the Server System Cover” on page 4. Remove the PCI riser assembly. For instructions, see “Removing the PCI Riser Assembly” on page ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 88: Figure 62. Removing A Full Height Add-In Card

    “Installing the Processor Air Duct” on page 11. Install the server system cover. For instructions, see “Installing the Server System Cover”. 12. Plug all peripheral devices and the AC power cable into the server. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 89: Replacing The Server Board

    6. Detach all cables connected to the server board. 7. Remove the heat sink and the processor. For instructions, see “Removing the Heat Sink and Processor” on page 8. Remove the DIMMs. For instructions, see “Removing DIMMs” on page ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 90: Figure 63. Removing The Server Board

    “Installing the Processor Air Duct” on page 16. Install the server system cover. For instructions, see “Installing the Server System Cover”. 17. Plug all peripheral devices and the AC power cable into the server. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 91: Installing The Server Board

    6. Place the server board into the server system as shown by letter “A” in the figure below. 7. Attach the server board with nine screws. See letter “B” in the figure. AF000678 Figure 64. Installing the Server Board ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 92: Replacing The Cmos Battery

    Kassera använt batteri enligt fabrikantens instruktion. Varoitus: Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan laitevalmistajan suosittelemaan tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden mukaisesti. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 93: Figure 65. Replacing The Cmos Battery

    8. Remove the new lithium battery from its package, and, being careful to observe the correct polarity, insert it in the battery socket. 9. Close the chassis. 10. Run the BIOS Setup utility to restore the configuration settings. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 94: Replacing The Power Supply (Sr1530Ah / Sr1530Ahlx)

    ✧ Optical drive power connector, if an optical drive is installed ✧ HDD0 power connector, if a hard drive is installed here ✧ HDD1 power connector, if a hard drive is installed here ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 95: Figure 66. Disconnecting Power Cables (Sr1530Ah / Sr1530Ahlx)

    AF000969 Figure 66. Disconnecting Power Cables (SR1530AH / SR1530AHLX) ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 96: Figure 67. Removing Power Supply From The Server System (Sr1530Ah / Sr1530Ahlx)

    See letter “B” in the figure. 7. Slide the power supply forward (see letter “C”) and then lift it from the chassis. AF000965 Figure 67. Removing Power Supply from the Server System (SR1530AH / SR1530AHLX) ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 97: Figure 68. Installing Power Supply Module Into The Server System (Sr1530Ah / Sr1530Ahlx)

    10. Insert the screw you removed in step 5 to attach the power supply to the server system. See letter “C”. AF000966 Figure 68. Installing Power Supply Module into the Server System (SR1530AH / SR1530AHLX) ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 98: Figure 69. Connecting Power Cables (Sr1530Ah / Sr1530Ahlx)

    Figure 69. Connecting Power Cables (SR1530AH / SR1530AHLX) 12. Install the server system cover. For instructions, see “Installing the Server System Cover”. 13. Plug all peripheral devices and the AC power cable into the server. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 99: Replacing The Power Supply (Sr1530Hahlx)

    6. Slide the power supply forward (see letter “C” in the figure below) and then lift it from the chassis. AF001630 Figure 70. Removing Power Supply from the Server System (SR1530HAHLX) ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 100: Figure 71. Installing Power Supply Module Into The Server System (Sr1530Hahlx)

    10. Install the server system cover. For instructions, see “Installing the Server System Cover”. 11. Plug all peripheral devices and the AC power cable into the server (see letter “C” in the figure above). ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 101: Replacing The Front Panel Board (Sr1530Ah/Sr1530Ahlx)

    “A” in the figure below. Save these screws. You will re-install them later. 7. Lift the front panel board from the system. See letter “B” in the figure. AF000967 Figure 72. Removing Front Panel Board from the Server System (SR1530AH/ SR1530AHLX) ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 102: Figure 73. Installing Front Panel Board Into The Server System (Sr1530Ah/Sr1530Ahlx)

    Figure 73. Installing Front Panel Board into the Server System (SR1530AH/ SR1530AHLX) 13. Install the server system cover. For instructions, see “Installing the Server System Cover”. 14. Plug all peripheral devices and the AC power cable into the server. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 103: Replacing The Front Panel Board (Sr1530Hahlx)

    6. Slide the front panel board back (see letter “B” in the figure below) and lift the front panel board from the system (see letter “C” in the figure below). AF001589 Figure 74. Removing Front Panel Board from the Server System (SR1530HAHLX) ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 104: Figure 75. Removing Light Pipes From The Front Panel Board (Sr1530Hahlx)

    9. Use the screw you removed in step 5 to attach the front panel board to the system (see letter “C” in the figure below). AF001590 Figure 76. Installing Front Panel Board into the Server System (SR1530HAHLX) ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 105: Figure 77. Installing Light Pipes On The Front Panel Board (Sr1530Hahlx)

    12. Connect the front panel cable. 13. Install the server system cover. For instructions, see “Installing the Server System Cover”. 14. Plug all peripheral devices and the AC power cable into the server. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 106: Replacing A Cooling Fan (Sr1530Ah / Sr1530Ahlx)

    4. Remove the processor air duct. For instructions, see “Removing the Processor Air Duct” on page 31 5. Disconnect the two fan cables from the server board. See letters “A” and “B” in the figure below. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 107: Figure 78. Disconnecting System Blower Fans (Sr1530Ah / Sr1530Ahlx)

    “B” from the figure. 8. Lift the fan bracket from the server. Lift the bracket at an angle, front of the bracket first, to clear the hard disk drive brackets. See letter “C”. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 108: Figure 79. Removing Bracket And System Blower Fans From Server System (Sr1530Ah / Sr1530Ahlx)

    AF000961 Figure 79. Removing Bracket and System Blower Fans from Server System (SR1530AH / SR1530AHLX) ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 109: Figure 80. Removing Fan From Fan Bracket (Sr1530Ah / Sr1530Ahlx)

    13. Route the cable from the fan at the right around the right side of the assembly and under the clip at the front of the fan bracket. 14. Connect the fans to the server board. See letters “A” and “B” in the following figure. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 110: Figure 81. Connecting System Blower Fans (Sr1530Ah / Sr1530Ahlx)

    AF001175 Figure 81. Connecting System Blower Fans (SR1530AH / SR1530AHLX) 15. Install the processor air duct. For instructions. see “Installing the Processor Air Duct” on page ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 111: Replacing The Pci Cooling Fan (Sr1530Ah/Sr1530Ahlx)

    4. Disconnect the fan cable from the server board. See letter “A” in the figure below. AF001176 Figure 82. Disconnecting the PCI Cooling Fan (SR1530AH/SR1530AHLX) 5. Lift the fan from the system. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 112: Figure 83. Removing The Pci Cooling Fan (Sr1530Ah/Sr1530Ahlx)

    7. Connect the fan cable to the server board. See letter “A” in Figure 8. Install the server system cover. For instructions, see “Installing the Server System Cover”. 9. Plug all peripheral devices and the AC power cable into the server. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 113: Replacing A Cooling Fan (Sr1530Hahlx)

    7. Disconnect the fan cable from the server board (see letter “B” in the figure below). 8. Lift the fan from the system (see letter “C” in the figure below). AF001633 Figure 84. Removing Fan from the Server System (SR1530HAHLX) ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 114: Figure 85. Installing Fan Into The Server System (Sr1530Hahlx)

    Figure 85. Installing Fan into the Server System (SR1530HAHLX) 12. Install the server system cover. For instructions, see “Installing the Server System Cover”. 13. Plug all peripheral devices and the AC power cable into the server. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 115: Installing And Removing The Rack Handles

    5. Repeat step 4 on the opposite side of the server. 6. Optional: Install the front bezel, if desired. For instructions, see “Installing the Front Bezel” on page 7. Plug all peripheral devices and the AC power cable into the server. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 116: Removing The Rack Handles

    5. Repeat step 4 on the opposite side of the system. 6. Optional: Install the front bezel, if desired. For instructions, see “Installing the Front Bezel” on page 7. Plug all peripheral devices and the AC power cable into the server. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 117: Appendix A: Technical Reference

    Appendix A: Technical Reference Cable Routing When you add or remove components from your server system, make sure your cables are routed correctly before reinstalling the server system cover. Use caution to make sure no cables or wires are pinched and that the airflow from the fans is not blocked. Use the figures below to determine the correct cable routing.
  • Page 118: Power Cable Routing (Sr1530Ah / Sr1530Ahlx)

    To make the diagram above more clear, where the connectors attach to components, the labels “F1”, “F2”, and “F3” are used. The end at the power supply itself is labeled “F” ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 119: Data Cable Routing (Sr1530Ah / Sr1530Ahlx)

    Data Cable Routing (SR1530AH / SR1530AHLX) Optical Device HDD 0 HDD 1 AF001206 Front panel USB Front panel SATA 0 to HDD0 Optical drive SATA 1 to HDD1 Figure 89. Data Cable Routing (SR1530AH / SR1530AHLX) ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 120: Cable Routing (Sr1530Hahlx)

    Blower Fan #2 Power HDD 0 to Server Board SATA 0 HDD 1 to Server Board SATA 1 HDD 2 to Server Board SATA 2 AF001632 Figure 90. Cable Routing (SR1530HAHLX) ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 121: 350W Single Power Supply Input Voltages

    Warning: Do not exceed a combined power output of 90 Watts for the +5 V and +3.3 V outputs. Exceeding a combined 90 Watts will overload the power subsystem and may cause the power supplies to overheat and malfunction. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 122: System Environmental Specifications

    7 Bels in sound power for a typical office ambient temperature (65-75 °F). Your selection of peripherals may change the noise level. Electrostatic Tested to 15 kilovolts (kV); no component damage. discharge (ESD) ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 123: Appendix B: Troubleshooting

    In addition to the server firmware and files, also update any drivers used for components you have installed in your system, such as video drivers, network drivers, and SATA drivers. Intel provides a package called the “Platform Confidence Test” that may help with your diagnostics. See “Server System References” on page x for a link to this software.
  • Page 124: Problems Following Initial System Installation

    • Are all integrated components from the tested components lists? Check the tested memory, and chassis lists, as well as the supported hardware and operating system list. See “Server System References” on page x for links to the tested component lists. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 125: Hardware Diagnostic Testing

    “No Characters Appear on Screen” on page 104. Specific Problems and Corrective Actions This section provides possible solutions for these specific problems: • Power light does not light. • No characters appear on screen. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 126: Power Light Does Not Light

    No Characters Appear on Screen Check the following: • Is the keyboard functioning? Test it by turning the “Num Lock” function on and off to make sure the Num Lock light is functioning. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 127: Characters Are Distorted Or Incorrect

    • Does this video monitor work correctly if plugged into a different system? System Cooling Fans Do Not Rotate Properly If the system cooling fans are not operating properly, it is an indication of possible system component failure. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 128: Drive Activity Light Does Not Light

    Try a different network cable. • Make sure you are using the correct and the current drivers. See “Server System References” on page x for a link to the current drivers. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 129: Problems With Network

    The add-in adapter stopped working without apparent cause • Reseat the adater. • The network driver files may be corrupt or deleted. Delete and then reinstall the drivers. • Run diagnostics. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 130: System Boots When Installing Pci Card

    • If you suspect that a transient voltage spike, power outage, or brownout might have occurred, reload the software and try running it again. Symptoms of voltage spikes ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 131: Devices Are Not Recognized Under Device Manager (Microsoft* Windows* Operating System)

    Devices are not Recognized under Device Manager (Microsoft* Windows* Operating System) The Microsoft* Windows* operating systems do not include all of the drivers for the ® Intel chipsets, onboard NICs, and other components. See “Server System References” on page x for a link to the current drivers and chipset files.
  • Page 132: Led Information

    LED Information ® The Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX includes LEDs that can aid in troubleshooting your system. A table of these LEDs with a description of their use is listed below. Table 8. LED Information LED Name...
  • Page 133: Appendix C: Installation/Assembly Safety Instructions

    5. Provide some electrostatic discharge (ESD) protection by wearing an antistatic wrist strap attached to chassis ground of the system-any unpainted metal surface-when handling components. 6. Do not operate the system with the chassis covers removed. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 134 • Provided with a properly grounded wall outlet. • Provided with sufficient space to access the power supply cord(s), because they serve as the product's main power disconnect. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 135: Deutsch

    5. Tragen Sie ein geerdetes Antistatik Gelenkband, um elektrostatische Ladungen (ESD) über blanke Metallstellen bei der Handhabung der Komponenten zu vermeiden. 6. Schalten Sie das System niemals ohne ordnungsgemäß montiertes Gehäuse ein. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 136 Bei falschem Einsetzen einer neuen Batterie besteht Explosionsgefahr. Die Batterie darf nur durch denselben oder einen entsprechenden, vom Hersteller empfohlenen Batterietyp ersetzt werden. Entsorgen Sie verbrauchte Batterien den Anweisungen des Herstellers entsprechend. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 137: Français

    Notez que le commutateur CC de mise sous tension /hors tension du panneau avant n'éteint pas l'alimentation CA du système. Pour mettre le système hors tension, vous devez débrancher chaque câble d'alimentation de sa prise. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 138 Le microprocesseur et le dissipateur de chaleur peuvent être chauds si le système a été sous tension. Faites également attention aux broches aiguës des cartes et aux bords tranchants du capot. Nous vous recommandons l'usage de gants de protection. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 139: Español

    No intente modificar ni usar el cable de alimentación de corriente alterna, si no corresponde exactamente con el tipo requerido. El número de cables suministrados se corresponden con el número de fuentes de alimentación de corriente alterna que tenga el producto ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 140 4. Inserte el bloqueo de seguridad en el sistema y bloquéelo para impedir que pueda accederse al mismo sin autorización. 5. Conecte todos los cables externos y los cables de alimentación CA al sistema. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 141 "Provisto de una toma de tierra correctamente instalada. • "Provisto de espacio suficiente como para acceder a los cables de alimentación, ya que éstos hacen de medio principal de desconexión del sistema. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 142: Italiano

    1. Aprire e rimuovere il lucchetto dal retro del sistema qualora ve ne fosse uno installato. 2. Togliere e mettere in un posto sicuro tutte le viti delle coperture. 3. Togliere le coperture. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 143 • "Dotata di una presa a muro correttamente installata. • "Dotata di spazio sufficiente ad accedere ai cavi di alimentazione, i quali rappresentano il mezzo principale di scollegamento del sistema. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 144 ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 145: Appendix D: Safety Information

    To reduce the risk of bodily injury, electrical shock, fire, and equipment damage, read this document and observe all warnings and precautions in ® this guide before installing or maintaining your Intel server product. In the event of a conflict between the information in this document and information provided with the product or on the website for a particular product, the product documentation takes precedence.
  • Page 146: Intended Application Uses

    Conform to local occupational health and safety requirements when moving and lifting equipment. • Use mechanical assistance or other suitable assistance when moving and lifting equipment. • To reduce the weight for easier handling, remove any easily detachable components. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 147: Power And Electrical Warnings

    Do not attempt to modify or use an AC power cord if it is not the exact type required. A separate AC cord is required for each system power supply. ® Some power supplies in Intel servers use Neutral Pole Fusing. To avoid risk of shock use caution when working with power supplies that use Neutral Pole Fusing.
  • Page 148: System Access Warnings

    To avoid risk of potential electric shock, a proper safety ground must be implemented for the rack and each piece of equipment installed in it. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 149: Electrostatic Discharge (Esd)

    Caution: To avoid risk of radiation exposure and/or personal injury: • Do not open the enclosure of any laser peripheral or device • Laser peripherals or devices have are not user serviceable • Return to manufacturer for servicing ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 150: Deutsch

    Deutsch Sicherheitshinweise für den Server ® ® Das vorliegende Dokument bezieht sich auf Intel Serverplatinen, Intel Servergehäuse (Standfuß und Rack) sowie installierte Peripheriegeräte. Es enthält Warnungen und Vorsichtsmaßnahmen zur Vermeidung von Gefahren durch Verletzung, Stromschlag, Feuer und Beschädigungen von Geräten. Lesen Sie diese Dokument daher sorgfältig, ®...
  • Page 151: Zielbenutzer Der Anwendung

    Verwenden Sie mechanische oder andere geeignete Hilfsmittel zum Transportieren oder Anheben von Geräten. • Entfernen Sie alle Komponenten, die sich leicht abnehmen lassen, um das Gewicht zu reduzieren und die Handhabung zu erleichtern. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 152: Warnungen Zu Netzspannung Und Elektrizität

    Typ entspricht. Jedes Netzteil im System muß über ein eigenes Netzkabel angeschlossen werden. Einige Netzteile von Intel Servern verwenden Nullleitersicherungen. Vorsicht ist geboten im Umgang mit Netzteilen, welche Nullleitersicherungen verwenden, um das Risiko eines elektrischen Schlages zu vermeiden Das Netzteil in diesem Produkt enthält keine Teile, die vom Benutzer gewartet werden...
  • Page 153: Warnhinweise Für Den Systemzugang

    Gehen Sie bei der Installation von Geräten im Rack immer von unten nach oben vor, und bauen Sie das schwerste Gerät an der untersten Position im Rack ein. Ziehen Sie jeweils immer nur ein Gerät aus dem Rack heraus. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 154: Elektrostatische Entladungen (Esd)

    Inbetriebnahme des Systems ohne Abdeckung kann zur Beschädigung von Systemkomponenten führen. So bringen Sie die Abdeckung wieder an: • Vergewissern Sie sich zunächst, daß Sie keine Werkzeuge oder Teile im Gehäuse vergessen haben. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 155: Français

    ® d’installer ou de mettre à jour votre produit serveur Intel En cas de conflit entre les informations fournies dans ce document et celles livrées avec le produit ou publiées sur le site Web pour un produit particulier, la documentation du produit prime.
  • Page 156: Domaines D'utilisation Prévus

    Bien ventilé et à l’écart des sources de chaleur telles que la lumière directe du soleil et les radiateurs. • À l’écart des sources de vibration ou des chocs physiques. • Isolé des champs électromagnétiques importants produits par des appareils électriques. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 157: Pratiques De Manipulation De L'équipement

    Vous devez les débrancher avant d’ouvrir le châssis, d’ajouter ou de supprimer un composant non connectable à chaud. Les alimentations de certains serveurs Intel sont munies de doubles fusibles pôle/neutre: veuillez observer les précautions d'usage afin d'éviter tout risque d'eléctrocution.
  • Page 158: Avertissements Sur Le Cordon D'alimentation

    Déconnectez l’alimentation secteur en débranchant tous les cordons d’alimentation secteur du système ou de la prise murale. • Déconnectez l’ensemble des câbles et lignes de télécommunication qui sont connectés au système. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 159: Avertissements Sur Le Montage En Rack

    étiqueté comme contrôlant toute l’unité, et pas uniquement le ou les serveurs. Pour éviter tout risque d’électrocution, le rack et chaque élément de l’équipement installé dans le rack doivent être correctement reliés à la terre. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 160: Décharges Électrostatiques (Esd)

    à l’intérieur du système. • Vérifiez que les câbles, les cartes d’extension et les autres composants sont correctement installés. • Fixez les panneaux au châssis en suivant les instructions du produit. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 161: Périphériques Laser

    Español Información de seguridad del servidor Este documento se aplica a las tarjetas de servidor de Intel®, las carcasas de servidor de Intel® (montaje en bastidor y en pedestal) y los dispositivos periféricos. Para reducir el riesgo de daños corporales, descargas eléctricas, fuego y en el equipo, lea este documento y preste atención a todos las advertencias y precauciones de esta guía antes de instalar o...
  • Page 162: Aplicaciones Y Usos Previstos

    Provista de una toma de corriente alterna correctamente conectada a tierra. • Provista de espacio suficiente para acceder a los cables de la fuente de alimentación ya que constituyen la desconexión principal de la alimentación. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 163: Manipulacién Del Equipo

    CA estén desenchufado antes de abrir la carcasa, agregar o extraer cualquier componente que no es de conexión en funcionamiento. Algunas fuentes de alimentación de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje. Para evitar riesgos de choques electricos use precauciónes al trabajar con las fuentes de alimentación que utilizan el polo neutral de fuselaje.
  • Page 164: Advertencias El Acceso Al Sistema

    Devuélvala al fabricante para repararla. • Apague el servidor y desconecte todos los cables de alimentación antes de agregar o reemplazar cualquier componente que no es de conexión en funcionamiento. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 165 Para que no llegue a tocar los componentes que estén calientes cuando esté realizando una instalación de conexión en funcionamiento, tenga cuidado al extraer o instalar los componentes de conexión en funcionamiento. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 166: Advertencias Sobre El Montaje En Bastidor

    Sujételas sólo por los bordes. Una vez extraída la tarjeta de su envoltorio de protección o del servidor, colóquela con el lado de los componentes hacia arriba sobre una superficie con toma de tierra y sin carga estática. Utilice una ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 167: Otros Riesgos

    • No abra la caja de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser reparados por el usuario • Haga que el fabricante los repare ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 168 ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 169: Appendix E: Regulatory And Compliance Information

    (or higher) and operating at the same (or higher) speed as the microprocessor used on this server board. The final configuration of your end system product may require additional EMC compliance testing. For more information, please contact your local Intel representative.
  • Page 170: Product Emc Compliance - Class A Compliance

    This server system has been tested and verified to comply with the following electromagnetic compatibility (EMC) regulations when installed in a compatible Intel® host system. For information on compatible host system(s) refer to Intel's Server Builder Web site or contact your local Intel representative.
  • Page 171: Certifications / Registrations / Declarations

    IRAM Certification (Argentina) • CNCA Certification (China) • Ecology Declaration (International) Product Regulatory Compliance Markings ® This Intel server system product is provided with the following regulatory marks. Table 10. Product Regulatory Compliance Markings Regulatory Compliance Region Marking cULus Listing Marks...
  • Page 172 C-Tick Mark Australia / New Zealand VCCI Marking (Class A) Japan BSMI Certification Taiwan Number & Class A Warning GOST R Marking Russia RRL MIC Mark Korea China Compulsory China Certification Mark ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 173: Electromagnetic Compatibility Notices

    (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. For questions related to the EMC performance of this product, contact: Intel Corporation 5200 N.E. Elam Young Parkway Hillsboro, OR 97124-6497 1-800-628-8686 This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
  • Page 174: Industry Canada (Ices-003)

    Install and use the equipment according to the instruction manual. BSMI (Taiwan) The BSMI Certification Marking and EMC warning is located on the outside rear area of the product. ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 175: Korean Compliance (Rrl)

    Updated product information for configurations can be found on the Intel Server Builder Web site at the following URL: http://channel.intel.com/go/serverbuilder If you do not have access to Intel's Web address, please contact your local Intel representative. •...
  • Page 176: Restriction Of Hazardous Substances (Rohs) Compliance

    Restriction of Hazardous Substances (RoHS) Compliance Intel has a system in place to restrict the use of banned substances in accordance with the European Directive 2002/95/EC. Compliance is based on declaration that materials banned in the RoHS Directive are either (1) below all applicable substance threshold limits or (2) an approved/pending RoHS exemption applies.
  • Page 177: Appendix F: Warranty

    "as is" unless specifically provided for otherwise in any software license accompanying the software. If any Product furnished by Intel which is the subject of this Limited Warranty fails during the warranty period for reasons covered by this Limited Warranty, Intel, at its option, will: •...
  • Page 178: Warranty Limitations And Exclusions

    Limitations of Liability Intel's responsibility under this, or any other warranty, implied or expressed, is limited to repair, replacement, or refund, as set forth above. These remedies are the sole and exclusive remedies for any breach of warranty.
  • Page 179: How To Obtain Warranty Service

    Telephone Support If you cannot find the information you need on Intel's World Wide Web site (http:// www.intel.com/), call your local distributor or an Intel Customer Support representative.
  • Page 180 ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 181: Appendix G: Getting Help

    Telephone All calls are billed per incident, levied in local currency at the applicable credit card exchange rate plus applicable taxes. (Intel reserves the right to change the pricing for telephone support at any time without notice). ® Before calling, fill out an Intel Server Issue Report Form.
  • Page 182: Latin America

    Easter Island....Contact AT&T USA at 800 800 311. Once connected, dial 800 843 4481 Mainland and Juan .. Contact AT&T USA at 800 225 288. Once connected, dial 800 843 4481 ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 183 Paraguay ... 001 916 377 0114 Peru ... 001 916 377 0114 Uruguay..001 916 377 0114 Venezuela... Contact AT&T USA at 0 800 2255 288. Once connected, dial 800 843 4481 ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...
  • Page 184 ® Intel Server System SR1530AH / SR1530AHLX / SR1530HAHLX...

Table of Contents