Summary of Contents for Intel SR1630GP - Server System - 0 MB RAM
Page 1
® Intel Server System SR1630GP / SR1630HGP Service Guide ® A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products Intel Order Number E73400-004...
Page 2
Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur.
Safety Information Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the ® Intel Server Deployment Toolkit CD and/or at http://support.intel.com/support/...
Page 4
® Intel Server System SR1630GP / SR1630HGP Service Guide...
Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Page 6
® Intel Server System SR1630GP / SR1630HGP Service Guide...
This includes how to navigate through the BIOS Setup screens, perform a BIOS update, and reset the password or CMOS. Information about the ® specific BIOS settings and screens is available in the Intel Server Board S3420GP Technical Product Specification.
Server System SR1630GP/SR1630HGP ships with the Intel Server Board S3420GPLC. ® There are two versions of this server system: the Intel Server System SR1630GP and the ® Intel Server System SR1630HGP. The contents of each server system are listed below.
® Intel Server System SR1630HGP Contents ® Your Intel Server System SR1630HGP ships with the following items: ® • One Intel Server Board S3420GPLC installed in the server system • One 350-W power supply module, installed in the server system •...
Guide in the product box. install it Accessories or other Intel Spares/Parts List & Configuration Guide server products This is available from your Intel field representative or on the Server Configurator Tool at: http://www.intel.com/support/motherboards/server/s3420gp/ howto.htm Hardware (peripheral For the Tested Hardware Operating Systems List, you can go to the ®...
Page 11
For this Information or Use this Document or Software Software For diagnostics test Diagnostics software http://support.intel.com/support/motherboards/server/S3420GP/ ® Intel Server System SR1630GP/SR1630HGP Service Guide...
Page 12
® Intel Server System SR1630GP/SR1630HGP Service Guide...
Warnings ..........................v Preface ........................vii About this Manual ........................ vii Manual Organization ......................vii Product Contents .........................viii ® Intel Server System SR1630GP Contents ..............viii ® Intel Server System SR1630HGP Contents ............... ix Server System References ....................x Chapter 1: Server System Features ................1 Chassis Component Identification ..................
Page 14
Removing the PCIe* Riser Assembly ................61 Installing the PCIe* Riser Assembly ................62 Installing or Replacing a PCIe* Riser Card ................. 63 Removing a PCIe* Riser Card ..................63 Installing a PCIe* Riser Card ..................64 ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Page 15
Drive Activity Light Does Not Light ................108 CD-ROM Drive or DVD-ROM Drive Activity Light Does Not Light ......108 Cannot Connect to a Server ..................108 Problems with Network ....................109 System Boots when Installing PCI Card ..............110 ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Page 16
Domaines d’utilisation prévus ................... 136 Sélection d’un emplacement ..................136 Pratiques de manipulation de l’équipement .............. 137 Alimentation et avertissements en matière d’électricité ..........138 Avertissements sur l’accès au système ..............138 ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Page 17
VCCI (Japan) ......................164 BSMI (Taiwan) ......................165 Korean Compliance (RRL) ..................165 End-of-Life / Product Recycling ..................165 Appendix F: Warranty .................... 167 ® Limited Warranty for Intel Chassis Subassembly Products ..........167 Appendix G: Getting Help ..................171 World Wide Web ........................171 Telephone ..........................171 ®...
Page 18
® xviii Intel Server System SR1630GP / SR1630HGP Service Guide...
List of Figures ® Figure 1. Intel Server System SR1630GP ................1 ® Figure 2. Intel Server System SR1630HGP................2 Figure 3. Front Controls and LEDs (SR1630GP) ..............5 Figure 4. Front Controls and LEDs (SR1630HGP) ..............7 Figure 5. Back Panel Connectors....................8 Figure 6.
Page 20
Figure 77. Installing the Rack Handle ..................94 Figure 78. Removing the Rack Handle ................... 95 Figure 79. Power Cable Routing (SR1630GP) ............... 98 Figure 80. Data Cable Routing (SR1630HGP) ............... 99 Figure 81. Cable Routing (SR1630HGP)................100 ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Page 21
® Table 2. Intel Server System SR1630GP Control Panel LED Functions ........ 5 Table 3. Intel® Server System SR1630HGP Control Panel LED Functions ......7 Table 4. NIC LED Descriptions ....................8 Table 5. Channel Slot Configuration ..................17 Table 6. Setup Menu Key Use ....................20 Table 7.
Page 22
® xxii Intel Server System SR1630GP / SR1630HGP Service Guide...
® Figure 2. Intel Server System SR1630HGP Note: Figure 2 is shown with an optional optical drive installed. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
23 pounds (10.43 kilograms) ® Server Board Intel Server Board S3420GPLC ® ® Processor Supports for one Intel Xeon 3400 Series Processor in FC-LGA 1156 socket package. • 2.5 GT/s point-to-point DMI interface to PCH • LGA 1156 pin socket...
Page 26
® Table 1. Intel Server System SR1630GP / SR1630HGP Feature Summary Feature Description • One Gigabit Ethernet device 82574L connect to PCI-E x1 interfaces on the PCH • One Gigabit Ethernet PHY 82578DM connected to PCH through PCI-E x1 interface...
Power Button NIC1 LED System Status LED NIC2 LED System Power LED Figure 3. Front Controls and LEDs (SR1630GP) ® Table 2. Intel Server System SR1630GP Control Panel LED Functions Color State Description NIC 1 / NIC 2 Green NIC Link / AC is on / no access...
® Table 2. Intel Server System SR1630GP Control Panel LED Functions Color State Description System Green Running / normal operation Status (on Blink System ready, but degraded standby power) Amber Critical or non-recoverable condition. Possible critical power module failure, critical fan failure, voltage (power...
NIC2 LED USB Port Power LED Power Button System Status LED Figure 4. Front Controls and LEDs (SR1630HGP) Table 3. Intel® Server System SR1630HGP Control Panel LED Functions Color State Description NIC 1 / NIC 2 Green NIC Link / System is On...
LAN link is established. Blinking LAN activity is occurring. 10 Mbit / sec data rate is selected Green 100 Mbit / sec data is selected Yellow 1000 Mbit / sec data rate is selected ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Note: Each drive can consume up to 17 W of power. Drives must be specified to run at a maximum ambient temperature of 45 ° ® Note: The Intel Server System SR1630GP / SR1630HGP does not support all Serial ATA (SATA) hard drives. See “Server System References” on page x for an Internet link to a list of supported hardware.
One slimline drive carrier is included with your server system; you must purchase the optical drive separately. To use the slimline DVD drive provided by Intel, use order code AXXSATADVDROM. To use the slimline DVD CDRW drive provided by Intel, use order code AXXSATADVDRWROM.
Server Board System Blower Fans (two) Processor Air Duct Hard Drive Bays PCIe* Riser Assembly Front Panel Processor and Heatsink Slimline Optical Drive Bay Power Supply Figure 6. System Components (SR1630GP) ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Front Panel Processor Air Duct Hard Drive Carriers (two) Server Board Slimline Optical Drive Bay PCIe* Riser Assembly M. Hard Drive Carrier (one) Processor and Heat Sink Figure 7. System Components (SR1630HGP) ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Slot 2, PCI Express* Gen1 x1 System FAN 2 and System ® (x4 connector) (Intel Server FAN 3 Board S3420GPLX only) Intel RMM3 Connector (Intel® CPU socket Server Board S3420GPLX only) Slot 3, PCI Express* Gen1 x4 CPU Fan connector (PCI Express* Gen2 compliant)
Jumper in normal position (pins 1-2) allows normal system operation with correct BIOS settings. System will POST normally. ® Jumper in maintenance mode (pins 2-3) allows Intel AMT setting/ password reset. Jumper removed is used to recover from a corrupted BIOS.
Xeon 3400 processor series with ® ® 95 W Thermal Design Power (TDP) with 2.5 GT/s or one Intel Xeon processor 3400 series with 65 W TDP with 2.5 GT/s. For a complete list of supported processors, see the links under “Server System...
Page 40
DIMM timings (RAS latency, CAS latency, etc.). ® ® The Intel SAS Entry RAID Module option is enabled by default once the Intel Entry RAID Module. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
You can run BIOS Setup with or without an operating system ® present. See the links under “Server System References” on page x for a link to the Intel Server Board S3420GP Technical Product Specification where you will find details about specific BIOS setup screens. Starting Setup You can enter and start BIOS Setup under several conditions: •...
If “No” is selected and <Enter> is pressed, or <Esc> is pressed, the user is returned to where they were before <F9> was pressed without affecting any existing field values. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
2. Write down the current settings in the BIOS Setup program. Note: Do not skip Step 2. You need these settings to configure your server at the end of the procedure. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
1. Power down and unplug the system from the AC power source. 2. Move the recovery jumper at JIF3 from the spare location at pins 2 and 3 to cover pins 1 and 2. Refer to the following figure. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
“clear” position clears both passwords. Before a new password(s) is set, you must restore the password clear jumper to its original position. 1. Power down the system and disconnect the AC power. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
2. Open the server chassis. For instructions, see your server chassis documentation. 3. Move the jumper from the default operating position (covering pins 1 and 2) to the reset / clear position (covering pins 2 and 3). ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Integrated BMC into an update mode, allowing the firmware to load safely onto the flash device. In the unlikely event the Integrated BMC firmware update process fails (due to the Integrated BMC not being in the proper update state), the server ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Page 48
9. Move jumper from the enabled position (covering pins 2 and 3) to the disabled position (covering pins 1 and 2). 10. Close the server chassis. 11. Reconnect the AC cord and power up the server. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Server System SR1630HGP are hot-swappable and are noted as such (where applicable) in the following instructions. ® Note: Most of the illustrations in this chapter show the Intel Server System SR1630GP with an optional optical drive installed. Unless otherwise noted, the instructions for removing and ®...
Removing and Installing the Front Bezel ® The front bezel is available as an optional accessory for the Intel Server System SR1630GP / SR1630HGP. Note the orientation in the following figures and make sure you position your bezel as shown.
2. Push the bezel onto the front of the server system until it clicks into place. 3. Lock the bezel. AF003247 Figure 15. Installing the Front Bezel ® Intel Server System SR1630GP / SR1630HGP Service Guide...
6. SR1630GP: Push rearward on the blue grip point at the front of the server. Slide the cover back until it stops and then lift the cover upward to remove it. See letter “C” in Figure 16. AF000662 Figure 16. Removing the Server System Cover (SR1630GP) ® Intel Server System SR1630GP / SR1630HGP Service Guide...
8. SR1630HGP: Push rearward on the blue grip point at the front of the server. Slide the cover back until it stops and then lift the cover upward to remove it. See letter “B” in Figure 17. AF001578 Figure 17. Removing the Server System Cover (SR1630HGP) ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Slide the cover forward. See letter “A” in Figure 19. 6. SR1630HGP: Install the four screws at the front of the server. See letter “B” in Figure 19. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
3. Remove the server system cover. For instructions, see “Removing the Server System Cover”. 4. Lift the processor air duct from its location behind the two system blower fans (see Figure 20 for SR1630GP; see Figure 21 for SR1630HGP). ® Intel Server System SR1630GP / SR1630HGP Service Guide...
AF003248 Figure 20. Removing the Processor Air Duct (SR1630GP) AF003249 Figure 21. Removing the Processor Air Duct (SR1630HGP) ® Intel Server System SR1630GP / SR1630HGP Service Guide...
5. Install the server system cover. For instructions, see “Installing the Server System Cover”. AF003250 Figure 22. Installing the Processor Air Duct (SR1630GP) ® Intel Server System SR1630GP / SR1630HGP Service Guide...
DIMM B2 starting from the center of the board. See “Memory” on page 14 for a discussion of the memory requirements and options. See “Server System References” on page x for a link to the list of tested DIMMs. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
“Installing the Server System Cover”. Removing DIMMs To remove a DIMM, follow these steps: 1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information” on page iii. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Page 60
6. Holding the DIMM by the edges, lift it from the socket, and store it in an anti-static package. 7. Install the server system cover. For instructions, see “Installing the Server System Cover”. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
9. Remove the processor. 10. If installing a replacement processor, see “Installing the Processor” on page Otherwise, install the protective socket cover over the empty processor socket and then reinstall the chassis cover. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Figure 25. Lifting the Processor Socket Handle 5. Push the rear tab with your finger to slightly lift the front of the load plate. Raise the load plate completely. Raise the CPU load plate (see Figure 26). ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Caution: Do not touch the socket pins; they are very sensitive and easily damaged. 6. Remove the processor from the packaging box and remove the protective shipping cover. See Figure 27. AF003189 Figure 27. Removing the Shipping Cover ® Intel Server System SR1630GP / SR1630HGP Service Guide...
9. Remove the protective socket cover. See Figure Figure 29. Removing the Protective Socket Cover Note: Retain the protective socket cover for use when removing a processor that will not be replaced. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Figure 30. Do not fully tighten one screw before tightening another. 5. Gradually and equally tighten each captive screw in the same order until each is firmly tightened. AF001049 Figure 30. Installing the Heat Sink ® Intel Server System SR1630GP / SR1630HGP Service Guide...
2. Power down the server. Unplug all peripheral devices and the AC power cable. 3. Remove the server system cover. For instructions, see “Removing the Server System Cover” on page 4. Locate the drive position you want to use. See Figure ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Figure 32. Save this screw. You will use it to reinstall the drive assembly later. 7. Lift the drive carrier from the chassis. See letter “B” in Figure 32. AF001050 Figure 32. Removing Drive Carrier from the Server System (SR1630GP) ® Intel Server System SR1630GP / SR1630HGP Service Guide...
“C” in Figure 34. Note: You must install the assembly that contains the optical drive bracket at the left side of the system. AF003253 Figure 34. Install Drive Assembly into the Server System (SR1630GP) ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Page 69
— Letter “B”: If a drive is installed in the HDD0 carrier, attach the middle connector on the daisy chain power cable to the HDD0 power connector. See letter “D” in Figure ® Intel Server System SR1630GP / SR1630HGP Service Guide...
2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the server system cover. For instructions, see “Removing the Server System Cover” on page ® Intel Server System SR1630GP / SR1630HGP Service Guide...
“Installing a Hard Disk Drive (SR1630GP)” on page 44, beginning with step 8. 10. Insert the screws that held the drive in the carrier into the screw locations on the carrier for future use. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Page 72
Note: You must install the assembly that contains the optical drive bracket at the left side of the system. 13. Install the server system cover. For instructions, see “Installing the Server System Cover”. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
1. If it is installed, remove the front bezel. For instructions, see “Removing the Front Bezel”. 2. Locate the drive position you want to use. See Figure AF003255 Figure 37. Locating Drive Positions (SR1630HGP) ® Intel Server System SR1630GP / SR1630HGP Service Guide...
9. Align the holes in the drive to the holes in the drive carrier and attach it to the carrier with the screws that were attached to the plastic retention device. See letter “B” in Figure 39. AF001584 Figure 39. Installing Drive into Drive Carrier (SR1630HGP) ® Intel Server System SR1630GP / SR1630HGP Service Guide...
7. With the black lever in the fully open position, slide the drive carrier into the server system. The green latch must be to the right. Do not push on the black lever until the lever begins to close by itself. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
“Removing the Front Bezel” on page 5. First time installation only: Remove the knock-out by rocking it back and forth. See letter “A” in Figure 41. You cannot reinstall the knock-out. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
8. Reinstall the screw that you removed in Step 5. 9. Connect the mini SATA power connector on the optical drive. 10. Connect the data cable to the optical drive and to the SATA connector on the server board. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
“C” in Figure 44. Save this screw. You will reinstall it later. 7. Slide the optical drive out through the front of the system. See letter “D” in Figure 44. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
10. Store the brackets for future use. 11. (Optional) Install the front bezel. For instructions, see “Installing the Front Bezel” on page 12. Install the server system cover. For instructions, see “Installing the Server System Cover”. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
5. First time installation only: Remove the peripheral knock-out by rocking it back and forth. 6. Attach the optical drive attachment bracket as shown in Figure 46. AF001643 Figure 46. Attaching the Optical Drive to the Attachment Bracket ® Intel Server System SR1630GP / SR1630HGP Service Guide...
5. Remove the screws holding the drive in place (see letters “A” and “B” in Figure 48) and slide the optical drive assembly out through the front of the chassis (see letter “C” in Figure 48). ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Figure 49. Removing the Optical Drive from the Attachment Bracket 7. (Optional) Install the front bezel. For instructions, see “Installing the Front Bezel” on page 8. Install the server system cover. For instructions, see “Installing the Server System Cover”. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
5. Lift riser assembly up to remove it. Use caution to gently ease the riser card from the add-in card slot so you do not damage the slot or the riser card. See Figure AF003259 Figure 50. Removing PCIe* Riser Assembly from the Server System ® Intel Server System SR1630GP / SR1630HGP Service Guide...
3. Press down uniformly until the two hooks on the rear of the PCIe* riser assembly engage the server system back panel slots. The riser cards will seat into the matching sockets on the server board. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
7. Remove the two screws that attach the riser card to the riser assembly. See Figure 52. Save these screws to be used later. AF003288 Figure 52. Removing Riser Card from Riser Assembly ® Intel Server System SR1630GP / SR1630HGP Service Guide...
10. Connect any cables to add-in cards that require them. See your add-in card documentation for information and add-in card requirements. 11. Re-install the processor air duct. For instructions, see “Installing the Processor Air Duct” on page ® Intel Server System SR1630GP / SR1630HGP Service Guide...
3. Remove the server system cover. For instructions, see “Removing the Server System Cover” on page 4. Remove the PCIe* Riser assembly. For instructions, see “Removing the PCIe* Riser Assembly” on page ® Intel Server System SR1630GP / SR1630HGP Service Guide...
3. Remove the server system cover. For instructions, see “Removing the Server System Cover” on page 4. Remove the PCIe* Riser assembly. For instructions, see “Removing the PCIe* Riser Assembly” on page ® Intel Server System SR1630GP / SR1630HGP Service Guide...
“Installing the Processor Air Duct” on page 11. Install the server system cover. For instructions, see “Installing the Server System Cover”. 12. Plug all peripheral devices and the AC power cable into the server. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
6. Detach all cables connected to the server board. 7. Remove the heat sink and the processor. For instructions, see “Removing the Heat Sink and Processor” on page 8. Remove the DIMMs. For instructions, see “Removing DIMMs” on page ® Intel Server System SR1630GP / SR1630HGP Service Guide...
14. Reconnect all cables to the server board. For a full cabling diagram, see Figure 80 on page 15. Install the processor air duct. For instructions, see “Installing the Processor Air Duct” on page ® Intel Server System SR1630GP / SR1630HGP Service Guide...
6. Place the server board into the server system as shown by letter “A” in Figure 57. 7. Attach the server board with nine screws. See letter “B” in Figure 57. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Kassera använt batteri enligt fabrikantens instruktion. Varoitus: Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan laitevalmistajan suosittelemaan tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden mukaisesti. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
8. Remove the new lithium battery from its package, and, being careful to observe the correct polarity, insert it in the battery socket. 9. Close the chassis. 10. Run the BIOS Setup utility to restore the configuration settings. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
— C: Daisy-chain cable to: Optical drive power connector, if an optical drive is installed HDD0 power connector, if a hard drive is installed here HDD1 power connector, if a hard drive is installed here ® Intel Server System SR1630GP / SR1630HGP Service Guide...
See letter “B” in Figure 60. 7. Slide the power supply forward (see letter “C”) and then lift it from the chassis. AF003264 Figure 60. Removing Power Supply from the Server System (SR1630GP) ® Intel Server System SR1630GP / SR1630HGP Service Guide...
10. Insert the screw you removed in Step 5 to attach the power supply to the server system. See letter “C” in Figure 61. AF003265 Figure 61. Installing Power Supply Module into the Server System (SR1630GP) ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Figure 62. Connecting Power Cables (SR1630GP) 12. Install the server system cover. For instructions, see “Installing the Server System Cover”. 13. Plug all peripheral devices and the AC power cable into the server. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
(see letter “B” in Figure 63). 6. Slide the power supply forward (see letter “C” in Figure 63) and then lift it from the chassis. AF003267 Figure 63. Removing Power Supply from the Server System (SR1630HGP) ® Intel Server System SR1630GP / SR1630HGP Service Guide...
10. Install the server system cover. For instructions, see “Installing the Server System Cover”. 11. Plug all peripheral devices and the AC power cable into the server (see letter “C” in Figure 64). ® Intel Server System SR1630GP / SR1630HGP Service Guide...
“D” in Figure 65. Save these screws. You will re-install them later. 7. Lift the front panel board from the system. See letter “E” in Figure 65. AF003269 Figure 65. Removing Front Panel Board from the Server System (SR1630GP) ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Figure 66. Installing Front Panel Board into the Server System (SR1630GP) 13. Install the server system cover. For instructions, see “Installing the Server System Cover”. 14. Plug all peripheral devices and the AC power cable into the server. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
6. Slide the front panel board back (see letter “B” in Figure 67) and lift the front panel board from the system (see letter “C” in Figure 67). AF003271 Figure 67. Removing Front Panel Board from the Server System (SR1630HGP) ® Intel Server System SR1630GP / SR1630HGP Service Guide...
(see letter “B” in Figure 69). 9. Use the screw you removed in Step 5 to attach the front panel board to the system (see letter “C” in Figure 69). ® Intel Server System SR1630GP / SR1630HGP Service Guide...
12. Connect the front panel cable. 13. Install the server system cover. For instructions, see “Installing the Server System Cover”. 14. Plug all peripheral devices and the AC power cable into the server. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
5. Disconnect the two fan cables from the server board (see letter “B” in Figure 71) and untie the cable tie (see letter “C” in Figure 71). AF003275 Figure 71. Disconnecting System Blower Fans (SR1630GP) ® Intel Server System SR1630GP / SR1630HGP Service Guide...
8. Lift the fan bracket from the server. Lift the bracket at an angle, front of the bracket first, to clear the hard disk drive brackets. See letter “C” in Figure 72. AF003276 Figure 72. Removing Bracket and System Blower Fans from Server System (SR1630GP) ® Intel Server System SR1630GP / SR1630HGP Service Guide...
13. Route the cable from the fan at the right around the right side of the assembly and under the clip at the front of the fan bracket. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
14. Connect the fans to the server board. See letters “A” and “B” in Figure 74. AF003277 Figure 74. Connecting System Blower Fans (SR1630GP) 15. Install the processor air duct. For instructions. see “Installing the Processor Air Duct” on page ® Intel Server System SR1630GP / SR1630HGP Service Guide...
5. Remove the two screws that hold the fan in place. Save these screws. You will re- install them later. 6. Disconnect the fan cable from the server board (see letter “B” in Figure 75). ® Intel Server System SR1630GP / SR1630HGP Service Guide...
9. Connect the fan cable to the server board (see letter “B” in Figure 76). 10. Install the processor air duct (see letter “C” in Figure 76). ® Intel Server System SR1630GP / SR1630HGP Service Guide...
3. If it is installed, remove the front bezel if it is installed. For instructions, see “Removing the Front Bezel” on page 4. Attach the rack handle to the server system with two screws as shown in Figure 77. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
5. Repeat Step 4 on the opposite side of the server. 6. (Optional) Install the front bezel, if desired. For instructions, see “Installing the Front Bezel” on page 7. Plug all peripheral devices and the AC power cable into the server. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
5. Repeat Step 4 on the opposite side of the system. 6. (Optional) Install the front bezel, if desired. For instructions, see “Installing the Front Bezel” on page 7. Plug all peripheral devices and the AC power cable into the server. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Page 118
® Intel Server System SR1630GP / SR1630HGP Service Guide...
For example, the PCI cooling fan cable is labeled with the letter “C” both where it connects to the server board and at the PCI cooling fan itself. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
To make Figure 79 more clear, where the connectors attach to the components, the labels “F1”, “F2”, and “F3” are used. The end at the power supply itself is labeled “F”. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Optical Drive Data to Server Board SATA 3 Link to backplane SPGIO Optical Drive to Power Supply Server Board SATA Connector Legend Begin cable connections at the SATA-0 location. AF003282 Figure 80. Data Cable Routing (SR1630HGP) ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Optical Drive Data to Server Board SATA 3 Link to backplane SPGIO Optical Drive to Power Supply Server Board SATA Connector Legend Begin cable connections at the SATA-0 location. AF003282 Figure 81. Cable Routing (SR1630HGP) ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Warning: Do not exceed a combined power output of 90 W for the +5 V and +3.3 V outputs. Exceeding a combined 90 W will overload the power subsystem and may cause the power supplies to overheat and malfunction. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
7 Bels in sound power for a typical office ambient temperature (65 to 75 °F). Your selection of peripherals may change the noise level. Electrostatic Tested to 8 Kilovotls (KV) contact discharge, 12 kilovolts (KV) air discharge; discharge (ESD) no component damage. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
In addition to the server firmware and files, also update any drivers used for components you installed in your system, such as video drivers, network drivers, and SATA drivers. Intel provides a package called the “Platform Confidence Test” that may help with your diagnostics. See “Server System References” on page x for a link to this software.
• Are all integrated components from the tested components lists? Check the tested memory and chassis lists, as well as the supported hardware and operating system list. See “Server System References” on page x for links to the tested component lists. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
“No Characters Appear on Screen” on page 106. Specific Problems and Corrective Actions This section provides possible solutions for these specific problems: • Power light does not light. • No characters appear on screen. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
No Characters Appear on Screen Check the following: • Is the keyboard functioning? Test it by turning the “Num Lock” function on and off to make sure the Num Lock light is functioning. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
• Does this video monitor work correctly if plugged into a different system? System Cooling Fans Do Not Rotate Properly If the system cooling fans are not operating properly, it is an indication of possible system component failure. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Try a different network cable. • Make sure you are using the correct and the current drivers. See “Server System References” on page x for a link to the current drivers. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
The add-in adapter stopped working without apparent cause • Reseat the adapter. • The network driver files may be corrupt or deleted. Delete and then reinstall the drivers. • Run diagnostics. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
• If you suspect a transient voltage spike, power outage, or brownout might have occurred, reload the software and try running it again. Symptoms of voltage spikes ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Devices are not Recognized under Device Manager (Microsoft Windows* Operating System) ® The Microsoft Windows* operating systems do not include all of the drivers for the Intel chipsets, onboard NICs, and other components. See “Server System References” on page x for a link to the current drivers and chipset files.
LED Information ® The Intel Server System SR1630GP / SR1630HGP includes LEDs that can aid in troubleshooting your system. Table 10 lists these LEDs and provides a description of their use. Table 10. LED Information LED Name Function Location LED Color...
5. Provide some electrostatic discharge (ESD) protection by wearing an antistatic wrist strap attached to chassis ground of the system-any unpainted metal surface-when handling components. 6. Do not operate the system with the chassis covers removed. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Page 136
Danger of explosion if the battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the equipment manufacturer. Dispose of used batteries according to manufacturer's instructions. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Netzgerät ein eigenes Netzkabel. Der Wechselstrom des Systems wird durch den Ein-/Aus-Schalter für Gleichstrom nicht ausgeschaltet. Ziehen Sie jedes Wechselstrom-Netzkabel aus der Steckdose bzw. dem Netzgerät, um den Stromanschluß des Systems zu unterbrechen. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Page 138
4. Bringen Sie die Verschlußeinrichtung (Padlock) wieder an und schließen Sie diese, um ein unerlaubtes Öffnen des Systems zu verhindern. 5. Schließen Sie alle externen Kabel und den AC Stromanschlußstecker Ihres Systems wieder an. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Le bloc d'alimentation de ce produit ne contient aucune pièce pouvant être réparée par l'utilisateur. Ce produit peut contenir plus d'un bloc d'alimentation. Veuillez contacter un technicien qualifié en cas de problème. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Page 140
1. Si un cadenas a été installé sur à l'arrière du système, déverrouillez-le et retirez-le. 2. Retirez toutes les vis des panneaux et mettez-les dans un endroit sûr. 3. Retirez les panneaux. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Page 141
• "Muni d'une prise murale correctement mise à la terre. • "Suffisamment spacieux pour vous permettre d'accéder aux câbles d'alimentation (ceux-ci étant le seul moyen de mettre le système hors tension). ® Intel Server System SR1630GP / SR1630HGP Service Guide...
- o a cualquier tipo de superficie de metal sin pintar. 6. No ponga en marcha el sistema si se han extraído las tapas del chasis. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Page 143
Existe peligro de explosión si la pila no se cambia de forma adecuada. Utilice solamente pilas iguales o del mismo tipo que las recomendadas por el fabricante del equipo. Para deshacerse de las pilas usadas, siga igualmente las instrucciones del fabricante. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Page 144
"Provisto de una toma de tierra correctamente instalada. • "Provisto de espacio suficiente como para acceder a los cables de alimentación, ya que éstos hacen de medio principal de desconexión del sistema. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
1. Aprire e rimuovere il lucchetto dal retro del sistema qualora ve ne fosse uno installato. 2. Togliere e mettere in un posto sicuro tutte le viti delle coperture. 3. Togliere le coperture. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Page 146
• "Dotata di una presa a muro correttamente installata. • "Dotata di spazio sufficiente ad accedere ai cavi di alimentazione, i quali rappresentano il mezzo principale di scollegamento del sistema. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
English Server Safety Information ® ® This document applies to Intel server boards, Intel server chassis and installed peripherals. To reduce the risk of bodily injury, electrical shock, fire, and equipment damage, read this document and observe all warnings and precautions in this guide before ®...
Provided with sufficient space to access the power supply cord(s), because they serve as the product's main power disconnect. Equipment Handling Practices Reduce the risk of personal injury or equipment damage: ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Do not attempt to modify or use an AC power cord if it is not the exact type required. A separate AC cord is required for each compute module power supply. ® Some power supplies in Intel servers use Neutral Pole Fusing. To avoid risk of shock use caution when working with power supplies that use Neutral Pole Fusing.
Do not attempt to recharge a battery. Do not attempt to disassemble, puncture, or otherwise damage a battery. Cooling and Airflow Caution: Carefully route cables as directed to minimize airflow blockage and cooling problems. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Das vorliegende Dokument bezieht sich auf Serverplatinen, Servergehäuse ® ® Intel Intel (Standfuß und Rack) sowie installierte Peripheriegeräte. Es enthält Warnungen und Vorsichtsmaßnahmen zur Vermeidung von Gefahren durch Verletzung, Stromschlag, Feuer und Beschädigungen von Geräten. Lesen Sie diese Dokument daher sorgfältig, bevor Sie Ihr Serverprodukt installieren oder warten.
Dieses Produkt wurde in seiner Eigenschaft als IT-Gerät getestet, das in Büros, Schulen, Computerräumen und ähnlichen öffentlichen Räumlichkeiten installiert werden kann. Die Eignung dieses Produkts für andere Einsatzbereiche als IT (z. B. Medizin, Industrie, Alarmsysteme oder Prüfgeräte) kann u. U. weitere Tests erfordern. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Verwenden Sie mechanische oder andere geeignete Hilfsmittel zum Transportieren oder Anheben von Geräten. • Entfernen Sie alle Komponenten, die sich leicht abnehmen lassen, um das Gewicht zu reduzieren und die Handhabung zu erleichtern. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Typ entspricht. Jedes Netzteil im System muß über ein eigenes Netzkabel angeschlossen werden. Einige Netzteile von Intel Servern verwenden Nullleitersicherungen. Vorsicht ist geboten im Umgang mit Netzteilen, welche Nullleitersicherungen verwenden, um das Risiko eines elektrischen Schlages zu vermeiden Das Netzteil in diesem Produkt enthält keine Teile, die vom Benutzer gewartet werden...
Ausbau aus dem Server mit der Bauelementseite nach oben auf eine geerdete, statisch entladene Unterlage.Verwenden Sie dazu, sofern verfügbar, eine leitfahige Schaumstoffunterlage, aber niche die Schutzhülle der Platine. Ziehen Sie die Platine nicht über eine Fläche. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Öffnen Sie keinesfalls das Gehäuse von Laser-Peripheriegeräten oder Laser- Komponenten. • Laser-Peripheriegeräte oder -Komponenten besitzen keine für den Benutzer wartungsbedürftigen Teile. • Schicken Sie das Gerät für Wartungsarbeiten an den Hersteller zurück. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Français Consignes de sécurité sur le serveur ® Ce document s’applique aux cartes serveur Intel , au châssis de serveur (sur pieds et ® Intel sur rack) et aux périphériques installés. Pour réduire les risques de dommages corporels, d’électrocution, d’incendie et de dommages matériels, lisez ce document et respectez tous les avertissements et précautions mentionnés dans ce guide avant d’installer ou de mettre...
Dans les régions sujettes aux orages magnétiques, nous vous recommandons de brancher votre système à un suppresseur de surtension et de déconnecter les lignes de télécommunication de votre modem pendant les orages. • Équipé d’une prise murale reliée à la terre. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
• Utilisez l’assistance mécanique ou toute autre assistance appropriée lorsque vous déplacez et soulevez le matériel. • Pour réduire le poids en vue de faciliter la manipulation, retirez tout composant amovible. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Vous devez les débrancher avant d’ouvrir le châssis, d’ajouter ou de supprimer un composant non connectable à chaud. Les alimentations de certains serveurs Intel sont munies de doubles fusibles pôle/neutre: veuillez observer les précautions d'usage afin d'éviter tout risque d'eléctrocution.
Afin de permettre une ventilation et un refroidissement corrects, ne mettez le système en marche que lorsque les panneaux du châssis sont en place. L’utilisation du système sans les panneaux peut endommager les composants système. Pour installer les panneaux : ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Retournez-les au fabricant en cas de problème. Español Información de seguridad del servidor ® Este documento se aplica a las tarjetas de servidor de Intel , los gabinetes de servidor de ® Intel (montaje en rack y en pedestal) y los dispositivos periféricos. Para reducir el riesgo de daños corporales, descargas eléctricas, fuego y en el equipo, lea este documento y...
(por ejemplo, soluciones médicas, industriales, residenciales, sistemas de alarma y equipos de pruebas). ® Intel Server System SR1630GP / SR1630HGP Service Guide...
CA estén desenchufado antes de abrir le gabinete, agregar o extraer cualquier componente que no es de conexión en funcionamiento. Algunas fuentes de alimentación de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje. Para evitar riesgos de choques eléctricos use precauciones al ®...
A no ser que esté instalando o extrayendo un componente de conexión en funcionamiento, deje que el sistema se enfríe antes de abrir las cubiertas. Para que no llegue a tocar los componentes que estén calientes cuando esté realizando una instalación ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Para instalar las cubiertas: • Compruebe primero que no ha dejado herramientas o piezas sueltas dentro del sistema. • Compruebe que los cables, tarjetas adicionales y otros componentes están instalados correctamente. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Page 167
• No abra la caja de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser reparados por el usuario • Haga que el fabricante los repare. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
(or higher) and operating at the same (or higher) speed as the microprocessor used on this server board. The final configuration of your end system product may require additional EMC compliance testing. For more information, please contact your local Intel representative.
This server system has been tested and verified to comply with the following ® electromagnetic compatibility (EMC) regulations when installed in a compatible Intel host system. For information on compatible host system(s) refer to Intel's Server Builder Web site or contact your local Intel representative. ®...
Product Ecology Requirements Intel has a system in place to restrict the use of banned substances in accordance with world wide product ecology regulatory requirements. Suppliers Declarations of Conformity to the banned substances must be obtained from all suppliers; and a Material Declaration Data Sheet (MDDS) must be produced to illustrate compliance.
— CE DOC (Europe) — CB Certificate & Report (International) Note: CB to include all CB national deviations) Certification marks to be visible on power supply. Power supply to comply with the Intel power supply specification. • Peripheral Devices (e.g. Disk Drives, CD ROMs) —...
Product Regulatory Compliance Markings ® This Intel server system product is provided with the following regulatory marks Table 12. .Product Regulatory Compliance Markings Regulatory Compliance Regionhgfhgf Marking IRAM Mark Argentina Ctick Mark Australia / NZ N232 CANADA ICES-003 CLASS A...
Page 181
(1) This device may not cause harmful interference, and (2) This device must accept interference receive, including interference that may cause undesired operation. Country of Country of Made in China Origin Mark Origin Mark ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Page 182
注意: 本設備包括多條電源系統電纜。為避免遭受電擊,在進行維 修之前應斷開兩 (2)條電源系統電纜。 German: Dieses Geräte hat mehr als ein Stromkabel. Um eine Gefahr des elektrischen Schlages zu verringern trennen sie beide (2) Stromkabeln bevor Instandhaltung. WEEE WEEE Marking Marking ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Page 183
This notice is required by California Code of Regulations, Title 22, Division 4.5, Chapter 33: Best Management Practices for Perchlorate Materials. This product / part includes a battery which contains Perchlorate material. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Page 184
Regulatory Compliance Regionhgfhgf Marking Standard icon for Power button Should be attached on power button ® Intel Server System SR1630GP / SR1630HGP Service Guide...
(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. For questions related to the EMC performance of this product, contact: Intel Corporation 5200 N.E. Elam Young Parkway Hillsboro, OR 97124-6497 1-800-628-8686 This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
Interference (VCCI) from Information Technology Equipment. If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. Install and use the equipment according to the instruction manual. ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Following is the RRL certification information for Korea. English translation of the notice above: 1. Type of Equipment (Model Name): On License and Product 2. Certification No.: On RRL certificate. Obtain certificate from local Intel representative 3. Name of Certification Recipient: Intel Corporation 4.
Page 188
® Intel Server System SR1630GP / SR1630HGP Service Guide...
"as is" unless specifically provided for otherwise in any software license accompanying the software. If any Product furnished by Intel which is the subject of this Limited Warranty fails during the warranty period for reasons covered by this Limited Warranty, Intel, at its option, will: •...
Limitations of Liability Intel's responsibility under this, or any other warranty, implied or expressed, is limited to repair, replacement, or refund, as set forth above. These remedies are the sole and exclusive remedies for any breach of warranty.
Telephone Support If you cannot find the information you need on Intel's World Wide Web site (http:// www.intel.com/), call your local distributor or an Intel Customer Support representative.
Page 192
® Intel Server System SR1630GP / SR1630HGP Service Guide...
Telephone All calls are billed per incident, levied in local currency at the applicable credit card exchange rate plus applicable taxes. (Intel reserves the right to change the pricing for telephone support at any time without notice). ® Before calling, fill out an Intel Server Issue Report Form.
Easter Island....Contact AT&T USA at 800 800 311. Once connected, dial 800 843 4481 Mainland and Juan .. Contact AT&T USA at 800 225 288. Once connected, dial 800 843 4481 ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Page 195
Paraguay ... 001 916 377 0114 Peru ... 001 916 377 0114 Uruguay..001 916 377 0114 Venezuela... Contact AT&T USA at 0 800 2255 288. Once connected, dial 800 843 4481 ® Intel Server System SR1630GP / SR1630HGP Service Guide...
Page 196
® Intel Server System SR1630GP / SR1630HGP Service Guide...
Need help?
Do you have a question about the SR1630GP - Server System - 0 MB RAM and is the answer not in the manual?
Questions and answers