® Intel Server System SR1630BC Service Guide ® A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products Intel Order Number E53480-001...
Page 2
Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur.
Page 3
® Intel Server System SR1630BC Service Guide...
Page 4
® Intel Server System SR1630BC Service Guide...
This document provides a brief overview of the features of the board/chassis, a list of accessories or other components you may need, troubleshooting ® information, and instructions on how to add and replace components on the Intel Server System SR1630BC. For the latest version of this manual, see http://support.intel.com/...
Product Contents ® ® The Intel Server System SR1630BC ships with the Intel Server Board S5500BC. For further information, see the the following documents: ® • Intel Server Board S5500BC Technical Product Specification ® • Intel Server System SR1630BC Technical Product Specification The contents of the server system are listed below.
Page 7
• Operating system • For information about which accessories, memory, processors, and third-party hardware were tested and can be used with your board, and for ordering information for Intel products, see: http://support.intel.com/support/motherboards/server/ S5500BC/compat.htm Intel® Server System SR1630BC Service Guide...
Page 8
Intel® Server System SR1630BC Service Guide...
Safety Information Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the ® Intel Server Deployment Toolkit 3.0 CD and/or at http://support.intel.com/support/...
Page 10
Intel® Server System SR1630BC Service Guide...
Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board. Intel® Server System SR1630BC Service Guide...
Page 12
Intel® Server System SR1630BC Service Guide...
Preface ......................... v About this Manual ........................v Manual Organization ......................v Product Contents ........................vi ® Intel Server System SR1630BC - Product Contents ........... Safety Information ..................... ix Important Safety Instructions ....................ix Wichtige Sicherheitshinweise ....................ix Consignes de sécurité ......................ix Instrucciones de seguridad importantes ................
Page 14
Memory Sparing and Mirroring..................... Power Supply ........................Optional Hardware ....................... ® Intel RAID Activation Key................... Hard Disk Drives ......................Chapter 3: Hardware Installations and Upgrades ..........23 Before You Begin ........................ Tools and Supplies Needed ..................System References ..................... Removing and Installing the Front Bezel ................
Page 15
400-W Single Power Supply Input Voltages ................67 400-W Single Power Supply Output Voltages ..............67 System Environmental Specifications ..................68 ® Appendix B: Intel Server Issue Report Form ............Appendix C: LED Decoder ..................Appendix D: Getting Help ..................Warranty Information ......................87 Telephone ..........................77 Appendix E: Regulatory and Compliance Information .........
Page 16
End-of-Life / Product Recycling..................Appendix F: Warranty .....................103 ® Limited Warranty for Intel Chassis Subassembly Products ..........Extent of Limited Warranty..................Warranty Limitations and Exclusions ................. Limitations of Liability ....................How to Obtain Warranty Service................Appendix G: Installation/Assembly Safety Instructions ........107...
Page 17
Advertencias de alimentacién y eléctricas ..............128 Advertencias sobre el cable de alimentación ............128 Advertencias el acceso al sistema ................129 Advertencias sobre el montaje en bastidor ...............130 Descarga electrostática (ESD) ..................131 Otros riesgos ......................131 ® Intel Server System SR1630BC Service Guide xvii...
Page 18
® xviii Intel Server System SR1630BC Service Guide...
Figure 5. Configuration Jumper Location ................Figure 6. Light Guided Diagnostic LEDs ................. Figure 7. Back Panel Connectors.................... ® Figure 8. Front Panel Control Panel - Intel Server System SR1630BC ........ Figure 9. Server System I/O Connector Locations..............Figure 10. Optional Peripherals....................
Page 20
Figure 52. Installing the Power Supply into the Server System ..........Figure 53. Installing the Rack Handle ..................Figure 54. Removing the Rack Handle ................... Figure 55. CMOS Recovery Jumper..................Figure 56. Password Recovery Jumper.................. Figure 57. Diagnostic LED Placement Diagram ..............Intel® Server System SR1630BC Service Guide...
List of Tables Table 1. Server System References ..................1 ® Table 2. Intel Server System SR1630BC Feature Summary ...........4 Table 3. NIC LED Descriptions ....................13 Table 4. Control Panel LED Functions ..................15 Table 5. Setup Menu Key Use ....................62 Table 6. 400-W Single Power Supply Output Voltages............67...
Page 22
® xxii Intel Server System SR1630BC Service Guide...
Intel Server System SR1630BC Quick Start User's Guide in the product and need to product box install it Accessories or other Intel Spares and Configuration Guide can be found at: server products http://support.intel.com/support/motherboards/server/S5500BC/ Hardware (peripheral Tested Hardware and Operating System List can be found at: boards, adapter cards) http://support.intel.com/support/motherboards/server/S5500BC/...
Page 24
Firmware Update can be found at: updates http://support.intel.com/support/motherboards/server/S5500BC/ For diagnostics test Diagnostics: Platform Confidence Test (PCT) software Found at: http://support.intel.com/support/motherboards/server/S5500BC/ ® and available on the Intel Server Deployment Toolkit 3.0 CD that ships with your system. Intel® Server System SR1630BC Service Guide...
Server System Features ® This chapter briefly describes the main features of the Intel Server System SR1630BC. This chapter provides illustrations of the product, a list of the server system features, and diagrams showing the location of important components and connections on the server system.
Processor 5500 Series in FC- LGA 1366 Socket B package with up to 95 W Thermal Design Power (TDP) • ® 4.8 GT/s, 5.86 GT/s, and 6.4 GT/s Intel QuickPath ® Interconnect (Intel QPI) For a complete list of supported processors, see: http://support.intel.com/support/motherboards/server/s5500bc/...
® Express* Gen2 x1 interface on the Intel IOH 5500 chipset • One Gigabit Ethernet device (82567) connects to the Gigabit ® LAN Connect Interface / LAN Connect Interface on the Intel ICH10R BIOS EFI BIOS ® Server Management Intel...
Rack handles (two) CPU Heatsink (two) Processor air duct System blower fans (two) System memory DIMM sockets Hard drives (two) PCI add-in card bracket Control panel Power supply Slimline optical drive Figure 3. System Components Intel® Server System SR1630BC Service Guide...
CC. System fan 1 header DD. DIMM sockets off Processor 2 socket (Channel D, E) EE. SATA SGPIO FF. SATA 0 GG. SATA 1 HH. SATA 2 Figure 4. Server Board Connector and Component Locations Intel® Server System SR1630BC Service Guide...
These pins should have a jumper in place for normal Recovery system operation.(Default) The main system BIOS will not boot with these pins jumpered. Note: The system boots from EFI-bootable recovery media with a recovery BIOS image. Intel® Server System SR1630BC Service Guide...
Jumper Name Pins What happens at system reset... J8B5: ME Force These pins should have a jumper in place for normal Update system operation (Default) ME force update model Figure 5. Configuration Jumper Location Intel® Server System SR1630BC Service Guide...
AC power is applied. • Fan Fault LEDs on the server board (see Figure 6) help identify failed and failing fans. The fan fault LEDs turn on (amber) if there is a fan fault. Intel® Server System SR1630BC Service Guide...
System Fan 2 Fault LED System ID LED CPU 1 Fan Fault LED HDD LED CPU 2 Fan Fault LED System Fan 3 Fault LED System Fan 1 Fault LED 5 VSB LED DIMM Fault LED Intel® Server System SR1630BC Service Guide...
No network connection Solid Amber Network connection in place Blinking Amber Transmit/receive activity Right LED 10 Mbps connection (if left LED is on or blinking) Solid Amber 100 Mbps connection Solid Green 1000 Mbps connection Intel® Server System SR1630BC Service Guide...
To enable RAID 5, this activation key is placed on the SATA Key connector that ® is located at the right side of the server board. For information on how to install the Intel RAID Activation Key AXXRAKSW5 accessory to enable RAID 5, see the documentation that is included with the accessory kit.
ACPI-compliant operating system. Status LED System power LED Hard drive activity LED NIC 1 LED NIC 2 LED ® Figure 8. Front Control Panel - Intel Server System SR1630BC Table 4. Control Panel LED Functions Color State Description NIC1/...
For instructions on installing the front bezel, see “Installing the Front Bezel”. The order number for the bezel is: • AHJBEZBLACK: Black bezel for use with the standard control panel. Intel® Server System SR1630BC Service Guide...
PCI Express* Slot Video Connector NIC 1 Connector (10 / 100 / 1000 Mb) NIC 2 Connector (10 / 100 / 1000 Mb) USB Ports 6 and 7 Figure 9. Server System I/O Connector Locations Intel® Server System SR1630BC Service Guide...
Hard Disk Drives The server system ships with two fixed drive carriers for installing two Serial ATA (SATA) fixed drives. For instructions on installing hard drives, see “Installing and Removing a Fixed Hard Drive”. Intel® Server System SR1630BC Service Guide...
Server System SR1630BC can be mounted into a rack. Intel provides three options to mount this server into a rack. When installing the chassis into a rack, Intel recommends you install systems from the bottom of the rack to the top. In other words, install the first system in the rack into the bottom position of the rack, the second system in the second position from the bottom, and so on.
DIMM farthest from the processor. See the following figure (Figure 12). For a complete list of supported memory DIMMs, see the links under “Server System References”. Intel® Server System SR1630BC Service Guide...
CAS latency, and so forth). Memory Sparing and Mirroring ® The spare mode is not supported by Intel Server System SR1630BC. With memory mirroring, the system maintains two copies of all data in the memory subsystem. If a DIMM fails, the data is not lost because the second copy of the data is available from the mirrored DIMM in the opposite channel.
Intel RAID Activation Key ® If RAID 5 is needed, you can install the optional Intel RAID Activation Key AXXRAKSW5. To enable RAID 5, this activation key is placed on the SATA Key connector located at the left side of the server board. For information on how to install the ®...
Removing and Installing the Front Bezel ® The front bezel is available as an optional accessory for the Intel Server System SR1630BC Service Guide. Bezel product code: AHJBEZBLACK.
At each end of the bezel, line up the center notch on the bezel with the center guide on the rack handles and push the bezel onto the front of the server system until it clicks into place. AF002891 Figure 14. Installing the Front Bezel ® Intel Server System SR1630BC Service Guide...
6. Slide the cover back until it stops and lift the cover upward to remove it (see letter “B”). Figure 15. Removing the Server System Cover Installing the System Cover 1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information” on page -ix. ® Intel Server System SR1630BC Service Guide...
2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the server system cover. For instructions, see “Removing the System Cover”. 4. Lift the processor air duct from its location behind the two system blower fans. ® Intel Server System SR1630BC Service Guide...
4. Lower the air duct into place; insert the two hooks at the front of the processor air duct into the corresponding slots on the bracket behind the two system blower fans. Use caution not to pinch or disengage cables that may be near or under the air duct. ® Intel Server System SR1630BC Service Guide...
2. Turn off all peripheral devices connected to the server. 3. Turn off the server. 4. Disconnect the AC power cord from the server. 5. Remove the cover from the server and locate the DIMM sockets (see “Installing the Memory”). ® Intel Server System SR1630BC Service Guide...
5. Gently spread the retaining clips at each end of the socket. The DIMM lifts from the socket. 6. Holding the DIMM by the edges, lift it from the socket, and store it in an anti-static package. ® Intel Server System SR1630BC Service Guide...
Page 52
7. Reinstall and reconnect any parts you removed or disconnected to reach the DIMM sockets. 8. Replace the server's cover and reconnect the AC power cord. ® Intel Server System SR1630BC Service Guide...
5. Locate the processor socket and open the socket lever (see Figure 20). Figure 20. Lifting the Load Lever 6. Open the load plate (see letter “A” in Figure 20 and letter “B” in Figure 21). ® Intel Server System SR1630BC Service Guide...
7. Remove the socket protective cover (see Figure 22). Figure 22. Remove the Socket Protective Cover 8. Take the processor out of the box and remove the protective shipping cover (Figure 23). Figure 23. Remove the Processor Protective Cover ® Intel Server System SR1630BC Service Guide...
Figure 25. Close the Load Plate and Socket Lever Note: Make sure the alignment triangle mark and the alignment triangle cutout align correctly. To assist in package orientation and alignment with the socket: ® Intel Server System SR1630BC Service Guide...
4. Using a #2 Phillips* screwdriver, finger-tighten each fastener diagonally according to the white-circled numbers (see Figure 27). 5. Securely re-tighten each fastener again in the same order as performed in Step 4. 6. Attach fan power cable to server board as shown. ® Intel Server System SR1630BC Service Guide...
8. Lift the heat sink from the processor. If it does not pull up easily, twist the heat sink again. Do not force the heat sink from the processor. Doing so could damage the processor. 9. Lift the processor lever. 10. Raise the CPU load plate. ® Intel Server System SR1630BC Service Guide...
AC power cord from the system or wall outlet. ® You can install up to two fixed SATA drives in the Intel Server System SR1630BC Service Guide. See “Server System References”...
3. Remove the screw that secures the hard drive bracket to the chassis (see letter "A" in the following figure). Save this screw. You will use it later to reinstall the drive assembly. Lift the drive carrier from the chassis (see letter "B"). ® Intel Server System SR1630BC Service Guide...
"B". Use the four screws provided to attach the drive to the carrier (see letter "C"). Figure 30. Installing Drive into the Drive Carrier ® Intel Server System SR1630BC Service Guide...
9. Connect the power cables to the drive(s): a. If a drive is installed in the HDD1 carrier, attach the connector on the daisy chain power cable that is closest to the power supply to the HDD1 connector. ® Intel Server System SR1630BC Service Guide...
3. Remove the screw that holds the hard drive bracket to the chassis (see letter "A" in the following figure). Save this screw. You will use it later to reinstall the drive assembly. Lift the drive carrier from the chassis (see letter "B"). ® Intel Server System SR1630BC Service Guide...
Installing or Removing a Slimline Optical Drive Caution: Slimline optical drives are NOT hot-swappable. Before removing or replacing the drive, you must first take the server out of service, turn off all peripheral devices connected to ® Intel Server System SR1630BC Service Guide...
Figure 34. Removing the Knockout in Bezel for Optical Opening oving Drive Blank from Drive Carrier 2. Attach the brackets to the optical drive using the four screws as shown in the following figure. ® Intel Server System SR1630BC Service Guide...
IDE connector on the server board.When the black drive carrier lever begins to close by itself, push on it to lock the drive assembly into place. Figure 36. Installing the Optical Drive into the Server System ® Intel Server System SR1630BC Service Guide...
2. Remove the screws and slide the optical drive assembly out of the chassis. AF002996 Figure 37. Removing the Slimline Optical Drive Assembly from the Server System 3. Remove the four screws from the brackets. Figure 38. Removing the Brackets from the Slimline Optical Drive Assembly ® Intel Server System SR1630BC Service Guide...
1. Lower the riser assembly into place (see letter "A"). 2. Align the two hooks in the riser assembly with the matching slots at the back of the server system (see letter "B"). ® Intel Server System SR1630BC Service Guide...
PCI bracket shield to the rear of the chassis to remove the shield. Retain the screw. 2. Insert the PCI card edge connector in the slot on the PCI riser. ® Intel Server System SR1630BC Service Guide...
4. Use the screw removed in step 1 to secure the riser card assembly to the chassis. Removing a PCI Add-In Card 1. Remove the screw holding the add-in card in place (see letter "A"). 2. Remove the PCI add-in card from the riser card connector (see letter "B"). ® Intel Server System SR1630BC Service Guide...
Use the following steps to replace a system blowers or the PCI cooling fan. Replacing the System Blower 1. Remove the processor air duct. For instructions, see “Removing the Processor Air Duct”. ® Intel Server System SR1630BC Service Guide...
3. Remove the two screws that secure the fan bracket in place. Save these screws. You will re-install them later (see letter "A" in the following figure). 4. Remove the fan cable from beneath the clip at the front of the fan bracket (see letter "B"). ® Intel Server System SR1630BC Service Guide...
Save these screws. You will reinstall them later. See letter "A" in the following figure). Lift the fan from the bracket (see letter "B"). Figure 46. Removing the System Blowers from the Bracket ® Intel Server System SR1630BC Service Guide...
10. Secure the blower assembly to the system using the two screws you removed previously. 11. Connect the blower cables to the server board. See letters "A" and "B" in the following figure. Figure 47. Connecting the System Blower Cables ® Intel Server System SR1630BC Service Guide...
7. Remove the seven screws from the server board (see letter "A") and lift the server board from the server system (see letter "B"). Figure 48. Removing the Server Board 8. Install the replacement server board. See “Installing the Server Board” on page -53. ® Intel Server System SR1630BC Service Guide...
5. Re-connect all SATA cables to the server board. 6. Install the PCI riser assembly. 7. Install the memory, processor heat sinks, and processors. 8. Install the CPU air duct and air baffle. ® Intel Server System SR1630BC Service Guide...
Varning: Explosionsfara vid felaktigt batteribyte. Använd samma batterityp eller en ekvivalent typ som rekommenderas av apparattillverkaren. Kassera använt batteri enligt fabrikantens instruktion. Varoitus: Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan laitevalmistajan suosittelemaan tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden mukaisesti. ® Intel Server System SR1630BC Service Guide...
Removing the Power Supply You can replace the power supply if it fails or if one of the fans integrated into it fails. To replace the power supply, use the following instructions. ® Intel Server System SR1630BC Service Guide...
(see letter “D”). AF002912 Figure 51. Removing the Power Supply from the Server System Installing the Power Supply 1. Insert the replacement power supply by first engaging the back panel (see letter “A”). ® Intel Server System SR1630BC Service Guide...
Installing and Removing the Rack Handles Installing the Rack Handles 1. Align the rack handle with the holes on the side of the server system and attach the rack handle with the two screws. ® Intel Server System SR1630BC Service Guide...
Removing the Rack Handles 1. Remove the two screws holding the rack handle in place, and remove the rack handle from the server system. Figure 54. Removing the Rack Handle ® Intel Server System SR1630BC Service Guide...
Page 82
® Intel Server System SR1630BC Service Guide...
You can run the BIOS Setup with or without an operating system ® being present. See “Server System References” for a link to the Intel Server Board S1630BC Technical Product Specification where you can find details about specific BIOS setup screens.
If "No" is selected and the <Enter> key is pressed, or if <Esc> is pressed, the user is returned to where they were before <F9> was pressed without affecting any existing field values. Intel® Server System SR1630BC Service Guide...
Press <F2> Key if you want to run SETUP 2. Write down the current settings in the BIOS Setup program. Note: Do not skip step 2. You need these settings to configure your server at the end of the procedure. Intel® Server System SR1630BC Service Guide...
2. Open the server. 3. Move the jumper from the normal operation position, CMOS Clear by MBX, at pins 1 and 2 to the CMOS Clear Force Erase position, covering pins 2 and 3. Intel® Server System SR1630BC Service Guide...
1. Power down the system and disconnect the AC power. 2. Open the server chassis. 3. Move the jumper from the normal operation position, Password Clear Protect, at pins 1 and 2 to the Password Clear Erase position, covering pins 2 and 3. Intel® Server System SR1630BC Service Guide...
6. Return the Password Reset jumper to the Password Clear Protect position, covering pins 1 and 2. Reconnect AC power and power up the server. 7. The password is now cleared and you can reset it by going into the BIOS setup. Intel® Server System SR1630BC Service Guide...
Appendix A: Technical Reference 400-W Single Power Supply Input Voltages • 100-127V at 47/63 Hz • 200-240V at 47/63 Hz 400-W Single Power Supply Output Voltages The following table lists the total wattage available from the power subsystem for each voltage.
(23 +/- degrees C) Sound Power: 7.0 BA in an idle state at typical office ambient temperature. (23 +/- 2 degrees C). Electrostatic +/-15 kV except I/O port +/-8 KV, per Intel Environmental Test discharge (ESD)* Specification. *The system requires the use of a shielded LAN cable to comply with Immunity regulatory requirements.
Date Submitted: _______________________________________________________ Company Name: ______________________________________________________ Contact Name: ________________________________________________________ Email Address: _______________________________________________________ Intel Server Product: ___________________________________________________ Priority (Critical, Hot, High, Low): _______________________________________ Brief Problem Description. Provide a brief description below. See the last page for space to include a detailed problem description.
DIMM D2 MB and Vendor / part number: __________________________________ DIMM E1 MB and Vendor / part number: __________________________________ DIMM E2 MB and Vendor / part number: __________________________________ Operating System Information Operating System:_____________________________________________________ Version: _____________________________________________________________ Service Pack:_________________________________________________________ Intel® Server System SR1630BC Service Guide...
Page 93
PCI Slot 6 PCI Slot 5 PCI Express* x4 PCI Slot 3 PCI 5V 32/33 32-bit/ 33 MHz PCI Slot 4 Video On-board Video Add-in Video On-Board NIC1 (10/100/1000 Mb) On-Board NIC2 (10/100/1000 Mb) Revision #NIC Intel® Server System SR1630BC Service Guide...
Page 94
In the space below, provide a complete description of the steps used to reproduce the problem or a complete description of where the problem can be found. Please also include any details on troubleshooting already done. ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ Intel® Server System SR1630BC Service Guide...
Page 95
____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ Intel® Server System SR1630BC Service Guide...
Page 96
Intel® Server System SR1630BC Service Guide...
Appendix C: LED Decoder During the system boot process, the BIOS executes a number of platform configuration processes, each of which is assigned a specific hex POST code number. As each configuration routine is started, the BIOS displays the POST code to the POST Code Diagnostic LEDs on the back edge of the server board.
(including AP) 0x12h Starting application processor initialization 0x13h SMM initialization 0x14h Selection of Processor with least feature use as Boot Strap Processor 0x15h Switch an AP processor to become the new Boot Strap Processor Intel® Server System SR1630BC Service Guide...
Unsupported or invalid DIMM configuration (system halted) 0xEAh DIMM training sequence failed (system halted) 0xEBh Memory test failed (system halted) 0xECh Unsupported or invalid DIMM configuration (system halted) 0xEDh Unsupported or invalid DIMM configuration (system halted) Intel® Server System SR1630BC Service Guide...
Page 100
Memory Initialization of Integrated Memory Controller 0xB1h Memory Initialization of Integrated Memory Controller 0xB2h Memory Initialization of Integrated Memory Controller 0xB3h Memory Initialization of Integrated Memory Controller 0xB4h Memory Initialization of Integrated Memory Controller Intel® Server System SR1630BC Service Guide...
Page 101
Memory Initialization of Integrated Memory Controller 0xBCh Memory Initialization of Integrated Memory Controller 0xBDh Memory Initialization of Integrated Memory Controller 0xBEh Memory Initialization of Integrated Memory Controller 0xBFh Memory Initialization of Integrated Memory Controller Intel® Server System SR1630BC Service Guide...
Page 102
ATA device 0x5Bh Reserved for ATA SMBUS 0x5Eh Resetting SMBUS 0x5Fh Reserved for SMBUS I/O Controller Hub 0x61h Initializing I/O Controller Super I/O 0x63h Initializing Super I/O Local Console 0x70h Resetting the video controller (VGA) Intel® Server System SR1630BC Service Guide...
Page 103
0x9Ah Detecting the presence of mouse 0x9Bh Enabling the mouse 0x9Ch Reserved for mouse Serial Port 0xA8h Resetting the serial port 0xA9h Disabling the serial port 0xAAh Detecting the presence of the serial port Intel® Server System SR1630BC Service Guide...
Page 104
Boot Device Selection (BDS) 0xD0 Entered the Boot Device Selection phase (BDS) 0xD1 Return to last good boot device 0xD2 Set up boot device selection policy 0xD3 Connect boot device controller 0xD4 Attempt flash update boot mode Intel® Server System SR1630BC Service Guide...
Page 105
Started connecting drivers DXE Drivers (not accompanied by a beep code) 0xE7h Waiting for user input 0xE8h Checking password 0xE9h Entering BIOS setup 0xEAh Flash Update 0xEBh Legacy Option ROM Initialization 0xECh DXE Drivers initialized Intel® Server System SR1630BC Service Guide...
Page 106
0x31h Crisis recovery has been initiated by software (corrupt flash) 0x34h Loading crisis recovery capsule 0x35h Handing off control to the crisis recovery capsule 0x36h Begin crisis recovery 0x3Eh No crisis recovery capsule detected Intel® Server System SR1630BC Service Guide...
Page 107
Table 10. Diagnostic LED POST Code Decoder 0x3Fh Crisis recovery capsule failed integrity check of capsule descriptors Intel® Server System SR1630BC Service Guide...
Page 108
Intel® Server System SR1630BC Service Guide...
— A searchable knowledgebase to search for product information throughout the support site 2. If you are still unable to obtain a solution to your issue, send an email to Intel’s technical support center using the online form available at http://supportmail.intel.com/scripts-emf/welcome.aspx...
Page 110
® Intel Server System SR1600UR Service Guide...
(or higher) and operating at the same (or higher) speed as the microprocessor used on this server board. The final configuration of your end system product may require additional EMC compliance testing. For more information, please contact your local Intel representative.
Product EMC Compliance - Class A Compliance Note: Legally the product is required to comply with Class A emission requirements as it is intended for a commercial type market place. Intel targets 10db margin to Class A Limits ® The Intel...
CSA 60950 - UL 60950 (Safety) Canada / USA Industry Canada CANADA ICES-003 CLASS A ICES-003 CANADA NMB-003 CLASSE A (Emissions) CFR 47, Part 15 (Emissions) China CNCA - CB4943 (Safety) GB 9254 (Emissions) GB17625 (Harmonics) ® Intel Server System SR1630BC User’s Guide...
Page 114
CE Declaration of Conformity Germany GS Certification - EN60950 International CB Certification - None Required IEC60950 CISPR 22 / CISPR 24 Japan VCCI Certification Korea RRL Certification MIC Notice No. 1997-41 (EMC) & 1997-42 (EMI) ® Intel Server System SR1630BC User’s Guide...
Page 115
Table 10. Product Regulatory Compliance Markings Compliance Regional Compliance Compliance Reference Marking Example Description Reference Russia GOST-R Certification GOST R 29216- 91 (Emissions) GOST R 50628- 95 (Immunity) Ukraine Ukraine None Required Certification Taiwan BSMI CNS13438 R33025 ® Intel Server System SR1630BC User’s Guide...
(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. For questions related to the EMC performance of this product, contact: Intel Corporation 5200 N.E. Elam Young Parkway Hillsboro, OR 97124-6497 1-800-628-8686 This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
Install and use the equipment according to the instruction manual. BSMI (Taiwan) The BSMI Certification Marking and EMC warning is located on the outside rear area of the product. ® Intel Server System SR1630BC User’s Guide...
The CCC Certification Marking and EMC warning is located on the outside rear area of the product. Product Ecology Compliance Intel has a system in place to restrict the use of banned substances in accordance with world wide product ecology regulatory requirements. The following is Intel's product ecology compliance criteria.
Page 119
Intel Internal All materials, parts and subassemblies None Required Specification must not contain restricted materials as defined in Intel's Environmental Product Content Specification of Suppliers and Outsourced Manufacturers - http:// supplier.intel.com/ehs/environmental.htm Europe Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/ EC - Mark applied to system level products only.
Page 120
Boxed Boards Intel Internal All materials, parts and subassemblies None Required must not contain restricted materials as Specification defined in Intel's Environmental Product Content Specification of Suppliers and Outsourced Manufacturers - http:// supplier.intel.com/ehs/environmental.htm. International ISO11469 - Plastic parts weighing >25gm >PC/ABS<...
兩 ( 2 ) 在進行 維 修之 前 應斷開 條電源 系 統電纜 German: Dieses Geräte hat mehr als ein Stromkabel. Um eine Gefahr des elektrischen Schlages zu verringern trennen sie beide (2) Stromkabeln bevor Instandhaltung ® Intel Server System SR1630BC User’s Guide...
Updated product information for configurations can be found on the Intel Server Builder Web site at the following URL: http://channel.intel.com/go/serverbuilder If you do not have access to Intel's Web address, please contact your local Intel representative. •...
End-of-Life / Product Recycling Product recycling and end-of-life take-back systems and requirements vary by country. Contact the retailer or distributor of this product for information about product recycling and / or take-back. ® Intel Server System SR1630BC User’s Guide...
Page 124
® Intel Server System SR1630BC User’s Guide...
"as is" unless specifically provided for otherwise in any software license accompanying the software. If any Product furnished by Intel which is the subject of this Limited Warranty fails during the warranty period for reasons covered by this Limited Warranty, Intel, at its option, will: •...
Limitations of Liability Intel's responsibility under this, or any other warranty, implied or expressed, is limited to repair, replacement, or refund, as set forth above. These remedies are the sole and exclusive remedies for any breach of warranty.
Telephone Support If you cannot find the information you need on Intel's World Wide Web site (http:// www.intel.com/), call your local distributor or an Intel Customer Support representative.
Page 128
Intel® Server System SR1630BC Service Guide...
Appendix G: Installation/Assembly Safety Instructions Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the Resource CD and/or at: http://support.intel.com/support/motherboards/server/sb/cs-010770.htm English...
Page 130
Wichtige Sicherheitshinweise Lesen Sie zunächst sämtliche Warn- und Sicherheitshinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu Intel-Serverplatinen und -Servergehäusen auf der Ressourcen-CD oder unter: http://support.intel.com/support/motherboards/server/sb/cs-010770.htm SICHERHEISMASSNAHMEN: Immer wenn Sie die Gehäuseabdeckung abnehmen um an das Systeminnere zu gelangen, sollten Sie folgende Schritte beachten: 1.
Page 131
Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce document avant de suivre toute instruction. Consultez Intel Server Boards and Server Chassis Safety Information sur le CD Resource CD ou bien rendez-vous sur le site: http://support.intel.com/support/motherboards/server/sb/cs-010770.htm...
Page 132
Instrucciones de seguridad importantes Lea todas las declaraciones de seguridad y precaución de este documento antes de realizar cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety Information en el CD Resource y/o en: http://support.intel.com/support/motherboards/server/sb/cs-010770.htm INSTRUCCIONES DE SEGURIDAD: Cuando extraiga la tapa del...
Page 133
Se il sistema è stato a lungo in funzione, il microprocessore e il dissipatore di calore potrebbero essere surriscaldati. Fare attenzione alla presenza di piedini appuntiti e parti taglienti sulle schede e sul telaio. È consigliabile l'uso di guanti di protezione. ® Intel Server System SR1630BC User’s Guide...
Page 134
® Intel Server System SR1630BC User’s Guide...
To reduce the risk of bodily injury, electrical shock, fire, and equipment damage, read this document and observe all warnings and precautions in ® this guide before installing or maintaining your Intel Server Product. In the event of a conflict between the information in this document and information provided with the product or on the website for a particular product, the product documentation takes precedence.
Conform to local occupational health and safety requirements when moving and lifting equipment. • Use mechanical assistance or other suitable assistance when moving and lifting equipment. • To reduce the weight for easier handling, remove any easily detachable components. Intel® Server System SR1630BC User’s Guide...
Deutsch Sicherheitshinweise für den Server ® ® Das vorliegende Dokument bezieht sich auf Intel Serverplatinen, Intel Servergehäuse (Standfuß und Rack) sowie installierte Peripheriegeräte. Es enthält Warnungen und Vorsichtsmaßnahmen zur Vermeidung von Gefahren durch Verletzung, Stromschlag, Feuer und Beschädigungen von Geräten. Lesen Sie diese Dokument daher sorgfältig, ®...
• Verwenden Sie mechanische oder andere geeignete Hilfsmittel zum Transportieren oder Anheben von Geräten. • Entfernen Sie alle Komponenten, die sich leicht abnehmen lassen, um das Gewicht zu reduzieren und die Handhabung zu erleichtern. Intel® Server System SR1630BC User’s Guide...
Typ entspricht. Jedes Netzteil im System muß über ein eigenes Netzkabel angeschlossen werden. Einige Netzteile von Intel Servern verwenden Nullleitersicherungen. Vorsicht ist geboten im Umgang mit Netzteilen, welche Nullleitersicherungen verwenden, um das Risiko eines elektrischen Schlages zu vermeiden Das Netzteil in diesem Produkt enthält keine Teile, die vom Benutzer gewartet werden...
Gehen Sie bei der Installation von Geräten im Rack immer von unten nach oben vor, und bauen Sie das schwerste Gerät an der untersten Position im Rack ein. Ziehen Sie jeweils immer nur ein Gerät aus dem Rack heraus. Intel® Server System SR1630BC User’s Guide...
System nur mit angebrachten Gehäuseabdeckungen betrieben werden. Die Inbetriebnahme des Systems ohne Abdeckung kann zur Beschädigung von Systemkomponenten führen. So bringen Sie die Abdeckung wieder an: • Vergewissern Sie sich zunächst, daß Sie keine Werkzeuge oder Teile im Gehäuse vergessen haben. Intel® Server System SR1630BC User’s Guide...
® d’installer ou de mettre à jour votre produit serveur Intel En cas de conflit entre les informations fournies dans ce document et celles livrées avec le produit ou publiées sur le site Web pour un produit particulier, la documentation du produit prime.
Bien ventilé et à l’écart des sources de chaleur telles que la lumière directe du soleil et les radiateurs. • À l’écart des sources de vibration ou des chocs physiques. • Isolé des champs électromagnétiques importants produits par des appareils électriques. Intel® Server System SR1630BC User’s Guide...
Vous devez les débrancher avant d’ouvrir le châssis, d’ajouter ou de supprimer un composant non connectable à chaud. Les alimentations de certains serveurs Intel sont munies de doubles fusibles pôle/neutre: veuillez observer les précautions d'usage afin d'éviter tout risque d'eléctrocution.
Éteignez le système en appuyant sur le bouton d’alimentation. • Déconnectez l’alimentation secteur en débranchant tous les cordons d’alimentation secteur du système ou de la prise murale. • Déconnectez l’ensemble des câbles et lignes de télécommunication qui sont connectés au système. Intel® Server System SR1630BC User’s Guide...
étiqueté comme contrôlant toute l’unité, et pas uniquement le ou les serveurs. Pour éviter tout risque d’électrocution, le rack et chaque élément de l’équipement installé dans le rack doivent être correctement reliés à la terre. Intel® Server System SR1630BC User’s Guide...
Vérifiez tout d’abord que vous n’avez pas oublié d’outils ou de composants détachés à l’intérieur du système. • Vérifiez que les câbles, les cartes d’extension et les autres composants sont correctement installés. • Fixez les panneaux au châssis en suivant les instructions du produit. Intel® Server System SR1630BC User’s Guide...
Retournez-les au fabricant en cas de problème. Español Información de seguridad del servidor ® Este documento se aplica a las tarjetas de servidor de Intel , las carcasas de servidor de ® Intel (montaje en bastidor y en pedestal) y los dispositivos periféricos. Para reducir el riesgo de daños corporales, descargas eléctricas, fuego y en el equipo, lea este documento...
Provista de una toma de corriente alterna correctamente conectada a tierra. • Provista de espacio suficiente para acceder a los cables de la fuente de alimentación ya que constituyen la desconexión principal de la alimentación. Intel® Server System SR1630BC User’s Guide...
CA estén desenchufado antes de abrir la carcasa, agregar o extraer cualquier componente que no es de conexión en funcionamiento. Algunas fuentes de alimentación de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje. Para evitar riesgos de choques electricos use precauciónes al trabajar con las fuentes de alimentación que utilizan el polo neutral de fuselaje.
Devuélvala al fabricante para repararla. • Apague el servidor y desconecte todos los cables de alimentación antes de agregar o reemplazar cualquier componente que no es de conexión en funcionamiento. Intel® Server System SR1630BC User’s Guide...
Para evitar el riesgo de descargas eléctricas, deberá instalar una conexión a tierra apropiada para el bastidor y para cada pieza del equipo instalada en el mismo. Intel® Server System SR1630BC User’s Guide...
Deseche las baterías respetando la normativa local. No intente recargar la batería. No intente desmontar, pinchar o causar cualquier otro desperfecto a una batería. Intel® Server System SR1630BC User’s Guide...
Page 154
Precaución Para evitar el riesgo de la exposición a radiaciones o de daños personales: • No abra la caja de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser reparados por el usuario • Haga que el fabricante los repare Intel® Server System SR1630BC User’s Guide...
Need help?
Do you have a question about the SR1630BC - Server System - 0 MB RAM and is the answer not in the manual?
Questions and answers