Page 1
Intel Server System SR1630BC ® Technical Product Specification Intel order number E44588-003 Revision 1.3 June, 2009 Enterprise Platforms and Services Division - Marketing...
Intel products are not intended for use in medical, life saving, or life sustaining applications. Intel may make changes to specifications and product descriptions at any time, without notice.
Intel® Server System SR1630BC Introduction Table of Contents Introduction..........................5 Chapter Outline ......................5 Server System Use Disclaimer ................5 Product Overview........................6 System Views ......................8 System Dimensions ....................8 System Components....................9 Hard Drive and Peripheral Bays................11 Server Board Overview ...................
Page 4
Intel® Server System SR1630BC Introduction Power Supply Fans....................25 Processor Air Duct and Air Baffle ................25 Peripheral and Hard Drive Support..................26 Optical Drive Support....................27 Hard Disk Drive Support ..................27 Front Control Panel........................ 28 6.1.1 Power / Sleep LED ....................29 6.1.2...
Page 5
List of Figures ® Figure 1. Intel Server System SR1630BC................... 8 ® Figure 2. Major System Components – Intel Server System SR1630BC ........9 Figure 3. Back Panel Features ....................10 ® Figure 4. Drive Bays – Intel Server System SR1630BC ............11 ®...
Page 6
Updated memory description in “Table 1. System Feature Set”........... ii Table 2. System Feature Set ......................6 ® Table 3. Intel Server System SR1630BC Dimensions ..............8 Table 4. Board Layout reference ....................13 ® Table 5. Intel Light-Guided Diagnostic LED reference .............. 15 Table 6.
Intel server building blocks are used together, the fully integrated system will meet the intended thermal requirements of supported components. It is the responsibility of the system integrator who chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of air flow required for their specific application and environmental conditions.
® The Intel Server System SR1630BC is a 1U server system designed to support the Intel Server Board S5500BC. The server board and the system have features designed to support the high-density server market. This chapter provides a high-level overview of the system features.
Page 9
Intel 5500 IOH chipset. One 82567 Gigabit Network Connection that connects to the Gigabit LAN Connect ® Interface / LAN Connect Interface on the Intel ICH10R Two 10/100/1000 Base-TX Interfaces through RJ-45 connectors with integrated magnetics.
Intel® Server System SR1630BC Product Overview System Views ® Figure 1. Intel Server System SR1630BC System Dimensions ® Table 3. Intel Server System SR1630BC Dimensions Height 1.7 inches Width without rails 16.9 inches Depth without CMA 20 inches Maximum weight 22 pounds Revision 1.3...
Power supply Slimline optical drive ® Figure 2. Major System Components – Intel Server System SR1630BC Note: The I/O connector locations on the back of the chassis are pre-cut, making an I/O shield unnecessary. You must install the supplied EMI gasket to maintain electromagnetic interference (EMI) compliance levels.
Intel® Server System SR1630BC Product Overview AC Power Connector NIC 2 Connector (10 / 100 / 1000 Mb) BMC Management Port Serial Port A USB Ports 6 and 7 Video Connector USB Ports 8 and 9 NIC 1 Connector (10 / 100 / 1000 Mb) PCI Express* Slot Figure 3.
Hard Drive and Peripheral Bays ® The Intel Server System SR1630BC is designed to support up to two fixed 3.5-inch Serial ATA (SATA) hard drives and one slimline optical device. Slimline optical drive bay Hard drive bay HDD0 (located under the...
Intel® Server System SR1630BC Product Overview Server Board Overview ® Figure 5. Intel Server Board S5500BC picture Revision 1.3 Intel order number E44588-003...
Intel® Server System SR1630BC Product Overview 2.5.1 Server Board Connector and Component Layout The following figure shows the board layout of the server board. Each connector and major component is identified by a number or letter, and a description is below the figure.
Intel® Server System SR1630BC Product Overview Description Description System fan 3 header Main power connector DIMM sockets for Channel A & B (Supports CPU_1) Power Supply Auxiliary Connector SSI 24-pin Front Panel connector System fan 2 header CPU_1 fan header CPU Power Connector ®...
Rack and Cabinet Mounting Options ® You can install the Intel Server System SR1630BC in 19-inch wide by up to 30-inch deep server cabinets. The system supports two rack mount options: A fixed mount relay rack / cabinet mount kit that can be configured to mount the system into either a 2-post or 4-post rack cabinet.
Intel® Server System SR1630BC Power Sub-System Power Sub-System The power sub-system consists of one, non-redundant high efficiency 400-W power supply that supports a 1U rack mount server system. The power supply and the power supply sub-system will have six outputs: 3.3 V, 5 V, 12 V1, 12V2, -12 V, and 5 VSB. The input is auto-ranging and power factor corrected.
Intel® Server System SR1630BC Power Sub-System Figure 9. Power Supply Mechanical Drawing Notes: 1. All dimensions are in mm. 2. The tolerance of the 40 mm height dimension (marked with letter C) pertains to the metal case only. Revision 1.3...
Intel® Server System SR1630BC Power Sub-System 3.2 Output Connectors The power supply has a cable harness with five power connectors used to power various platform sub-systems. The following table defines each power connector. Table 6. Cable Harness Definition Label Length (mm)
Intel® Server System SR1630BC Power Sub-System Table 8. P2 – Processor/DDR3 Power Connector Pin-out Signal 18 Awg Color Signal 18 Awg Color Black +12V1 Yellow Black +12V1 Yellow Black +12V1 Yellow Black +12V1 Yellow 3.2.3 P3 – Power Signal Connector...
Intel® Server System SR1630BC Power Sub-System 3.2.5 P6 – Slim-line SATA Optical Disk Drive Power Connector Connector housing: 6-pin SATA Power Contact: 15u plating minimum Table 11. P6 – Slim-line SATA Optical Disk Drive Power Connector Pin-out Signal 22 AWG Color Reserved N.C.
Intel® Server System SR1630BC Power Sub-System Protection Circuits Protection circuits inside the power supply should cause only the power supply’s main outputs to shut down. If the power supply latches off due to a protection circuit tripping, an AC cycle off for 15 seconds and a PSON cycle high for 1 second should be able to reset the power supply.
Intel® Server System SR1630BC Power Sub-System Output Voltage Minimum (V) Maximum (V) +12 V1,2 13.3 14.5 -12 V -13.3 -14.5 +5 VSB 3.5.3 Over-temperature Protection (OTP) The power supply is protected against over temperature conditions caused by loss of fan cooling or excessive ambient temperature.
You must properly install the air duct and the top cover to maintain the required airflow within the system. ® Note: The Intel Server System SR1630BC does not support redundant cooling. If a fan blower fails, you must power down the system as soon as possible so you can replace the failed fan blower. AF001524 ®...
Primary cooling for CPU1, IOH, and system memory 4.1.1 System Fan Connectors ® The Intel Server System SR1630BC supports two system fan blowers. The pin-out for the connector is provided in the following table. Table 17. System Fan Connector Pin-outs J3K2 - SYS_FAN1 J8K3 - SYS_FAN2...
Processor Air Duct and Air Baffle The system requires the use of the system air duct to direct airflow and sustain appropriate air pressure. ® Figure 12. Air Duct for the Intel Server System SR1630BC Revision 1.3 Intel order number E44588-003...
Peripheral and Hard Drive Support ® The Intel Server System SR1630BC provides support for two fixed hard drive bays and one slim-line peripheral drive bay at the front of the system. The fixed hard drive bays are designed to support SATA 3.5-inch drives.
Hard Disk Drive Support ® The Intel Server System SR1630BC can support up to two 3.5-inch by 1-inch fixed SATA hard disk drives. The drives are mounted inside the systems. Revision 1.3 Intel order number E44588-003...
ACPI-compliant operating system. Status LED System power LED Hard drive activity LED NIC 1 LED NIC 2 LED ® Figure 14. Front Control Panel – Intel Server System SR1630BC Table 18. Control Panel LED Functions Color State Description NIC Link/no access...
Intel® Server System SR1630BC Front Control Panel Color State Description HDD access Green Random blink Disk Activity No hard disk activity The current limiting resistors for the power LED, system fault LED, and NIC LEDs are located ® on the Intel Server Board S5500BC.
Intel® Server System SR1630BC Front Control Panel Color State Criticality Description Non-fatal alarm – system is likely to fail: CATERR asserted. Critical temperature threshold asserted. Critical voltage threshold asserted. Amber Blink Non-critical Critical fan threshold asserted.
Intel® Server System SR1630BC PCI Riser Cards and Assembly PCI Riser Cards and Assembly ® The Intel Server Board S5500BC provides one PCI Express* x8 slot which supports one riser card with one riser card slot. The riser card supports one low-profile, half-length PCI Express* x8 add-in card which consumes power less than 15 W.
5 Hz to 500 Hz, 2.20 g RMS random Shock, operating Half sine, 2 g peak, 11 mSec ESD* +/-15 KV except I/O port +/-8 KV per the Intel Environmental test specification System Cooling 2550 BTU/hour Requirement in BTU/Hr ®...
Kassera använt batteri enligt fabrikantens instruktion. VAROITUS Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan laitevalmistajan suosittelemaan tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden mukaisesti. Revision 1.3 Intel order number E44588-003...
URL: http://www.intel.com/go/serverbuilder If you do not have access to Intel’s Web address, please contact your local Intel representative. Server chassis (base chassis is provided with power supply and fans)UL listed. Server boardyou must use an Intel server board—UL recognized.
Markings below are typical markings however, may vary or be different based on how certification is obtained. ® Note: The Intel Server System SR1630BC meets Class A Certifications Emissions requirements. Table 23. Product Safety & Electromagnetic (EMC) Compliance Compliance Regional...
Page 38
RRL Certification MIC Notice No. 1997-41 (EMC) & 1997-42 (EMI) 인증번호: CPU-Model Name (A) Russia GOST-R Certification GOST R 29216-91 (Emissions) GOST R 50628-95 (Immunity) Ukraine Ukraine Certification None Required Taiwan BSMI CNS13438 R33025 Revision 1.3 Intel order number E44588-003...
TV reception. All cables used to connect to peripherals must be shielded and grounded. Operation with cables, connected to peripherals that are not shielded and grounded may result in interference to radio and TV reception. Revision 1.3 Intel order number E44588-003...
8.6.6 BSMI (Taiwan) The BSMI Certification number and the following warning is located on the product safety label which is located on the bottom side (pedestal orientation) or side (rack mount configuration). Revision 1.3 Intel order number E44588-003...
The CCC Certification Marking and EMC warning is located on the outside rear area of the product. Product Ecology Compliance Intel has a system in place to restrict the use of banned substances in accordance with world wide product ecology regulatory requirements. The following is Intel’s product ecology compliance criteria.
Not applied to internal packaging such as plastics, foams, etc. Intel Internal All materials, parts and subassemblies must not Specification contain restricted materials as defined in Intel’s Environmental Product Content Specification of None Required Suppliers and Outsourced Manufacturers – http://supplier.intel.com/ehs/environmental.htm...
Page 43
Compliance Reference Description Marking Example Intel Internal All materials, parts and subassemblies must not Specification contain restricted materials as defined in Intel’s Environmental Product Content Specification of None Required Suppliers and Outsourced Manufacturers – http://supplier.intel.com/ehs/environmental.htm International ISO11469 - Plastic parts weighing >25gm are intended to be marked with per ISO11469.
“Laite on liitettävä suojamaadoituskoskettimilla varustettuun pistorasiaan.” English on line 4: “Connect only to a properly earth grounded outlet.” Country of Origin Logistic Requirements Applied to products to indicate where product was Made in XXXX made. Revision 1.3 Intel order number E44588-003...
This section provides a list of useful information unique to the Intel Server System SR1630BC that you should keep in mind while integrating the server system. ® The Intel Server System SR1630BC requires the use of a shielded LAN cable to comply with Immunity regulatory requirements. ® ® Intel...
LED #6 LED #5 LED #4 LED #3 LED #2 LED #1 LED #0 Status Upper nibble bits = 1010b = Ah; Lower nibble bits = 1100b = Ch; the two are concatenated as ACh. Revision 1.3 Intel order number E44588-003...
Configuring memory parameters in the memory controller 0x26h Optimizing memory controller settings 0x27h Initializing memory, such as ECC init 0x28h Testing memory PCI Bus 0x50h Enumerating PCI buses 0x51h Allocating resources to PCI buses Revision 1.3 Intel order number E44588-003...
Page 48
Trying to boot device selection 0 0xD1 Trying to boot device selection 1 0xD2 Trying to boot device selection 2 0xD3 Trying to boot device selection 3 0xD4 Trying to boot device selection 4 Revision 1.3 Intel order number E44588-003...
Page 49
Crisis recovery has been initiated because of a user request 0x31h Crisis recovery has been initiated by software (corrupt flash) 0x34h Loading crisis recovery capsule 0x35h Handing off control to the crisis recovery capsule 0x3Fh Unable to complete crisis recovery capsule Revision 1.3 Intel order number E44588-003...
Major 0141 PCI resource conflict Major 0146 PCI out of resources error Major 0192 Processor 0x cache size mismatch detected. Fatal 0193 Processor 0x stepping mismatch. Minor 0194 Processor 0x family mismatch detected. Fatal Revision 1.3 Intel order number E44588-003...
Appendix C: POST Error Messages and Handling Error Code Error Message Response 0195 Processor 0x Intel(R) QPI speed mismatch. Major 0196 Processor 0x model mismatch. Fatal 0197 Processor 0x speeds mismatched. Fatal 0198 Processor 0x family is not supported. Fatal 019F Processor and chipset stepping configuration is unsupported.
Page 52
Serial Port component encountered an input error. Minor 92C8 Serial Port component encountered an output error. Minor 94C6 LPC component encountered a controller error. Minor 94C9 LPC component encountered a resource conflict error. Major Revision 1.3 Intel order number E44588-003...
Power fault: DC Power unit sensors – power unit failure offset. power unexpectedly lost (power good dropout) 1-5-4-4 Power control fault Power unit sensors – soft power control failure offset. (Power good assertion timeout) Revision 1.3 Intel order number E44588-003...
Page 54
The user can override this option by setting the POST Error Pause option as disabled on the BIOS setup Main screen. If this option is disabled, the system boots the operating system without user intervention. The default is disabled. Revision 1.3 Intel order number E44588-003...
Mean Time to Repair Over-temperature Protection Over-voltage Protection Power Factor Correction Power Supply Unit Ring Indicate Single Connector Attachment Sensor Data Record Single-Ended UART Universal Asynchronous Receiver Transmitter Universal Serial Bus VCCI Voluntary Control Council for Interference Revision 1.3 Intel order number E44588-003...
® ® ® Intel Server Board S5500BC / Intel Server Chassis SC5650 / Intel Server System SR1630BC Spares/Parts List and Configuration Guide ® Intel S5500 Chipsets Server Board BIOS External Product Specification Revision 1.3 Intel order number E44588-003...